User Parameter Tables<br />

•Torque Detection: L6<br />

Parameter<br />

Number<br />

L6-01<br />

L6-02<br />

L6-03<br />

L6-04<br />

Name<br />

Display<br />

Torque<br />

detection selection<br />

1<br />

Torq Det 1 Sel<br />

Torque detection<br />

level 1<br />

Torq Det 1 Lvl<br />

Torque detection<br />

time 1<br />

Torq Det 1 Time<br />

Torque detection<br />

selection 2<br />

Torq Det 2 Sel<br />

Description<br />

0: Torque detection disabled.<br />

1: Car stuck detection only with<br />

speed agreement; operation<br />

continues (warning is output).<br />

2: Car stuck detected<br />

continuously during operation;<br />

operation continues<br />

(warning is output).<br />

3: Car stuck detection only with<br />

speed agreement; output<br />

stopped upon detection.<br />

4: Car stuck detected<br />

continuously during operation;<br />

output stopped upon detection.<br />

5: Undertorque detection only<br />

with speed agreement;<br />

operation continues (warning<br />

is output).<br />

6: Undertorque detected<br />

continuously during operation;<br />

operation continues<br />

(warning is output).<br />

7: Undertorque detection only<br />

with speed agreement; output<br />

stopped upon detection.<br />

8: Undertorque detected<br />

continuously during operation;<br />

output stopped upon detection.<br />

Vector control: Motor rated torque<br />

is set as 100%.<br />

V/f control: Inverter rated current<br />

is set as 100%.<br />

Sets the overtorque/undertorque<br />

detection time.<br />

Setting<br />

Range<br />

Factory<br />

Setting<br />

Control Methods<br />

V/f<br />

Open<br />

Loop<br />

Vector<br />

Closed<br />

Loop<br />

Vector<br />

Change<br />

during<br />

Operation<br />

MEMO-<br />

BUS<br />

Register<br />

Page<br />

0 to 8 4 No A A A 4A1H 5-34<br />

0 to 300 150% No A A A 4A2H 5-34<br />

0.0 to<br />

10.0<br />

0.1 s No A A A 4A3H 5-34<br />

0 to 8 0 No A A A 4A4H 5-34<br />

4<br />

L6-05<br />

L6-06<br />

Torque detection<br />

level 2<br />

Torq Det 2 Lvl<br />

Torque detection<br />

time 2<br />

Torq Det 2 Time<br />

See L6-01 to L6-03 for a description.<br />

0 to<br />

300<br />

0.0 to<br />

10.0<br />

150% No A A A 4A5H 5-34<br />

0.1 s No A A A 4A6H 5-34<br />

4-33