User Parameter Tables<br />
•Torque Detection: L6<br />
Parameter<br />
Number<br />
L6-01<br />
L6-02<br />
L6-03<br />
L6-04<br />
Name<br />
Display<br />
Torque<br />
detection selection<br />
1<br />
Torq Det 1 Sel<br />
Torque detection<br />
level 1<br />
Torq Det 1 Lvl<br />
Torque detection<br />
time 1<br />
Torq Det 1 Time<br />
Torque detection<br />
selection 2<br />
Torq Det 2 Sel<br />
Description<br />
0: Torque detection disabled.<br />
1: Car stuck detection only with<br />
speed agreement; operation<br />
continues (warning is output).<br />
2: Car stuck detected<br />
continuously during operation;<br />
operation continues<br />
(warning is output).<br />
3: Car stuck detection only with<br />
speed agreement; output<br />
stopped upon detection.<br />
4: Car stuck detected<br />
continuously during operation;<br />
output stopped upon detection.<br />
5: Undertorque detection only<br />
with speed agreement;<br />
operation continues (warning<br />
is output).<br />
6: Undertorque detected<br />
continuously during operation;<br />
operation continues<br />
(warning is output).<br />
7: Undertorque detection only<br />
with speed agreement; output<br />
stopped upon detection.<br />
8: Undertorque detected<br />
continuously during operation;<br />
output stopped upon detection.<br />
Vector control: Motor rated torque<br />
is set as 100%.<br />
V/f control: Inverter rated current<br />
is set as 100%.<br />
Sets the overtorque/undertorque<br />
detection time.<br />
Setting<br />
Range<br />
Factory<br />
Setting<br />
Control Methods<br />
V/f<br />
Open<br />
Loop<br />
Vector<br />
Closed<br />
Loop<br />
Vector<br />
Change<br />
during<br />
Operation<br />
MEMO-<br />
BUS<br />
Register<br />
Page<br />
0 to 8 4 No A A A 4A1H 5-34<br />
0 to 300 150% No A A A 4A2H 5-34<br />
0.0 to<br />
10.0<br />
0.1 s No A A A 4A3H 5-34<br />
0 to 8 0 No A A A 4A4H 5-34<br />
4<br />
L6-05<br />
L6-06<br />
Torque detection<br />
level 2<br />
Torq Det 2 Lvl<br />
Torque detection<br />
time 2<br />
Torq Det 2 Time<br />
See L6-01 to L6-03 for a description.<br />
0 to<br />
300<br />
0.0 to<br />
10.0<br />
150% No A A A 4A5H 5-34<br />
0.1 s No A A A 4A6H 5-34<br />
4-33