User Constants<br />

Table 9.7 User Constants<br />

No.<br />

Name<br />

Factory<br />

Setting<br />

S1-05 DC injection braking time at stop 0.60<br />

Setting<br />

S1-06 Brake release delay time 0.20<br />

S1-07 Brake close delay time 0.10<br />

S1-14 SE2 detection delay time 200ms<br />

S1-15 SE3 detection delay time 200ms<br />

S1-16 Run delay time 0.10sec<br />

S1-17 DC injection current gain at regenerative operation 100%<br />

S1-18 DC injection current gain at motoring operation 20%<br />

S1-19 Output contactor open delay time 0.10sec<br />

S1-20 Zero servo gain 5<br />

S1-21 Zero servo completion width 10<br />

S1-22 Starting torque compensation increase time 500ms<br />

S1-23 Torque compensation gain during lowering 1.000<br />

S1-24 Torque compensation bias during raising 0.0%<br />

S1-25 Torque compensation bias during lowering 0.0%<br />

9<br />

S1-26 Dwell speed at start reference 0.0Hz<br />

S1-27 Door zone speed level 0.0Hz<br />

S2-01 Motor rated speed 1380 rpm<br />

S2-02 Slip compensation gain in motoring mode 0.7<br />

S2-03 Slip compensation gain in regenerative mode 1.0<br />

S2-07 Slip compensation delay time 200ms<br />

S3-01 Short floor operation selection 0<br />

T1-01 Autotuning mode selection 0<br />

T1-02 Motor output power *1<br />

T1-03 Motor rated voltage *1<br />

T1-04 Motor rated current *1<br />

T1-05 Motor base frequency 60.0 Hz<br />

T1-06 Number of motor poles 4 poles<br />

T1-07 Motor base speed 1450 r/min<br />

T1-08 Number of PG pulses 1024<br />

T1-09 Motor no-load current E2-03 value<br />

* The factory setting depends on the inverter model and the control method.<br />