User Parameter Tables<br />

Parameter<br />

Number<br />

F1-06<br />

F1-08<br />

F1-09<br />

F1-10<br />

F1-11<br />

F1-14<br />

Name<br />

Display<br />

PG division rate<br />

(PG pulse monitor)<br />

PG Output Ratio<br />

Sets the division ratio for the PG<br />

speed control card pulse output.<br />

Division ratio = (1+ n) /m<br />

(n=0 or 1 m=1 to 32)<br />

The first digit of the value of F1-<br />

06 stands for n, the second and<br />

the third stands for m.<br />

This parameter is effective only<br />

when a PG-B2 is used.<br />

The possible division ratio settings<br />

are: 1/32 ≤ F1-06<br />

≤ 1.<br />

1 to 132 1 No No No A 385H 5-66<br />

Overspeed detection<br />

Sets the overspeed detection<br />

level<br />

PG Overspd<br />

Level<br />

Overspeed detection<br />

delay time<br />

PG Overspd<br />

Time<br />

Excessive speed<br />

deviation detection<br />

level<br />

PG Deviate<br />

Level<br />

Excessive speed<br />

deviation detection<br />

delay time<br />

method.<br />

Motor speeds that continue to<br />

exceed the value set in F1-08<br />

(set as a percentage of the maximum<br />

output frequency) for the<br />

time set in F1-09 are detected as<br />

overspeed faults.<br />

Sets the speed deviation detection<br />

method.<br />

Any speed deviation above the<br />

F1-10 set level (set as a percentage<br />

of the maximum output frequency)<br />

that continues for the<br />

time set in F1-11 is detected as a<br />

speed deviation.<br />

The speed deviation is the difference<br />

between actual motor speed<br />

PG Deviate Time and the speed reference command.<br />

PG open-circuit<br />

detection delay<br />

time<br />

PGO Detect<br />

Time<br />

Description<br />

Used to set the PG disconnection<br />

detection time. PGO will be<br />

detected if the detection time<br />

exceeds the set time.<br />

Setting<br />

Range<br />

0 to 120 115% No No No A 387H 5-66<br />

0.0 to 2.0 0.0 s No No No A 388H 5-66<br />

0 to 50 10% No No No A 389H 5-67<br />

0.0 to<br />

10.0<br />

0.0 to<br />

10.0<br />

Factory<br />

Setting<br />

Control Methods<br />

V/f<br />

Open<br />

Loop<br />

Vector<br />

Closed<br />

Loop<br />

Vector<br />

Change<br />

during<br />

Operation<br />

MEMO-<br />

BUS<br />

Register<br />

Page<br />

0.5 s No No No A 38AH 5-67<br />

1.0 s No No No A 38DH 5-66<br />

4<br />

4-21