Carrier Frequency Derating and Current Limitation<br />

Current limitation level at low speeds<br />

Varispeed L7 limits the output current at low frequencies. This current limitation does not change with the<br />

carrier frequency selection. The current limitation in the low frequency is as follows.<br />

150%<br />

140% 200V Class 15kW<br />

400V Class 30kW<br />

130%<br />

120%<br />

110%<br />

200V Class11kW<br />

200V Class 3.7, 18, 30kW<br />

400V Class 18, 22kW<br />

200V Class 5.5kW<br />

400V Class 3.7, 5.5, 7.5, 11, 55kW<br />

0<br />

200V Class 7.5, 22 , 37, 45, 55kW<br />

400V Class 4.0, 15, 37, 45kW<br />

1.5Hz<br />

3Hz<br />

4.5Hz<br />

6Hz<br />

Output<br />

Frequency<br />

IMPORTANT<br />

Fig 5.31 Low frequency current limitation<br />

• If the torque at low frequencies is too low, check whether the current runs into the limitation explained<br />

above. If so, check the motor data settings (E2-) and the V/f pattern (E1-).<br />

• If the current still runs into the limit it might be necessary to install a one size bigger inverter.<br />

• When selecting an inverter please consider the low frequency current limit as described above and<br />

select an inverter with an appropriate current margin.<br />