Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Parameter<br />
Number<br />
U1-44<br />
U1-45<br />
Name<br />
Display<br />
ASR output without<br />
filter<br />
ASR Output w Fil<br />
Feed forward<br />
control output<br />
FF Cout Output<br />
Description<br />
Monitors the output from the<br />
speed control loop (i.e., the primary<br />
filter input value). 100% is<br />
displayed for rated secondary current<br />
of the motor.<br />
Monitors the output from feed forward<br />
control. 100% is displayed<br />
for rated secondary current of the<br />
motor.<br />
Output Signal Level During<br />
Multi-Function Analog<br />
Output<br />
10 V: Rated secondary current<br />
of motor<br />
(-10 V to 10 V)<br />
10 V: Rated secondary current<br />
of motor<br />
(-10 V to 10 V)<br />
Min.<br />
Unit<br />
Control Methods<br />
V/f<br />
Open<br />
Loop<br />
Vector<br />
Closed<br />
Loop<br />
Vector<br />
MEMO-<br />
BUS<br />
Register<br />
0.01% No No A 6BH<br />
0.01% No No A 6CH<br />
U1-50<br />
Slip compensation<br />
value<br />
Slip comp value<br />
Monitors the slip compensation<br />
value.100% is displayed<br />
for rated slip<br />
10 V: Rated slip of motor<br />
( -10 V to 10 V)<br />
0.01% A A A 71H<br />
U1-51<br />
Max Current during<br />
acceleration<br />
Max Amp<br />
at accel<br />
Monitors the maximum currnet<br />
during acceleration.<br />
10 V: Rated current of motor<br />
(0 V to 10 V)<br />
0.1 A A A A 72H<br />
U1-52<br />
Max Current during<br />
deceleration<br />
Max Amp<br />
at decel<br />
Monitors the maximum currnet<br />
during deceleration.<br />
10 V: Rated current of motor<br />
(0 V to 10 V)<br />
0.1 A A A A 73H<br />
U1-53<br />
Max Current during<br />
Top speed<br />
Max Amp<br />
at top speed<br />
Monitors the maximum currnet at<br />
top speed.<br />
10 V: Rated current of motor<br />
(0 V to 10 V)<br />
0.1 A A A A 74H<br />
U1-54<br />
Max Current during<br />
leveling speed<br />
Monitors the maximum currnet at<br />
Vl speed.<br />
Max Amp<br />
at Vl sped<br />
10 V: Rated current of motor<br />
(0 V to 10 V)<br />
0.1 A A A A 75H<br />
U1-55<br />
Operation counter Monitors the lift operation<br />
Operation Cnt coumter .<br />
O2-15 can clear this counter.<br />
(Cannot be output.) times A A A 76H<br />
4-48