Parameter<br />

Number<br />

U1-44<br />

U1-45<br />

Name<br />

Display<br />

ASR output without<br />

filter<br />

ASR Output w Fil<br />

Feed forward<br />

control output<br />

FF Cout Output<br />

Description<br />

Monitors the output from the<br />

speed control loop (i.e., the primary<br />

filter input value). 100% is<br />

displayed for rated secondary current<br />

of the motor.<br />

Monitors the output from feed forward<br />

control. 100% is displayed<br />

for rated secondary current of the<br />

motor.<br />

Output Signal Level During<br />

Multi-Function Analog<br />

Output<br />

10 V: Rated secondary current<br />

of motor<br />

(-10 V to 10 V)<br />

10 V: Rated secondary current<br />

of motor<br />

(-10 V to 10 V)<br />

Min.<br />

Unit<br />

Control Methods<br />

V/f<br />

Open<br />

Loop<br />

Vector<br />

Closed<br />

Loop<br />

Vector<br />

MEMO-<br />

BUS<br />

Register<br />

0.01% No No A 6BH<br />

0.01% No No A 6CH<br />

U1-50<br />

Slip compensation<br />

value<br />

Slip comp value<br />

Monitors the slip compensation<br />

value.100% is displayed<br />

for rated slip<br />

10 V: Rated slip of motor<br />

( -10 V to 10 V)<br />

0.01% A A A 71H<br />

U1-51<br />

Max Current during<br />

acceleration<br />

Max Amp<br />

at accel<br />

Monitors the maximum currnet<br />

during acceleration.<br />

10 V: Rated current of motor<br />

(0 V to 10 V)<br />

0.1 A A A A 72H<br />

U1-52<br />

Max Current during<br />

deceleration<br />

Max Amp<br />

at decel<br />

Monitors the maximum currnet<br />

during deceleration.<br />

10 V: Rated current of motor<br />

(0 V to 10 V)<br />

0.1 A A A A 73H<br />

U1-53<br />

Max Current during<br />

Top speed<br />

Max Amp<br />

at top speed<br />

Monitors the maximum currnet at<br />

top speed.<br />

10 V: Rated current of motor<br />

(0 V to 10 V)<br />

0.1 A A A A 74H<br />

U1-54<br />

Max Current during<br />

leveling speed<br />

Monitors the maximum currnet at<br />

Vl speed.<br />

Max Amp<br />

at Vl sped<br />

10 V: Rated current of motor<br />

(0 V to 10 V)<br />

0.1 A A A A 75H<br />

U1-55<br />

Operation counter Monitors the lift operation<br />

Operation Cnt coumter .<br />

O2-15 can clear this counter.<br />

(Cannot be output.) times A A A 76H<br />