20.09.2015 Views

Contents

Contents

Contents

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Digital Operator Copy Function Faults<br />

These faults can occur during the digital operator COPY function. When a fault occurs, the fault content is displayed<br />

on the operator. A fault does not activate the fault contact output or alarm output.<br />

Table 6.25 Digital Operator/Monitor Copy Function Faults<br />

Function<br />

Digital Operator/Monitor<br />

Display<br />

Probable Causes<br />

Corrective Actions<br />

PRE<br />

READ IMPOSSIBLE<br />

o3-01 was set to 1 to write parameter into the Digital<br />

Operator/Monitor when the Operator was<br />

write-protected (o3-02 = 0).<br />

Set o3-02 to enable writing parameters into the<br />

Operator’s memory.<br />

READ<br />

Function<br />

IFE<br />

READ DATA ERROR<br />

The data file read from the Inverter was of the<br />

wrong size indicating corrupted data.<br />

Retry the READ command (o3-01 = 1).<br />

Check the Digital Operator/Monitor’s cable.<br />

Replace the Digital Operator/Monitor.<br />

RDE<br />

DATA ERROR<br />

An attempted writing of the Inverter data to the<br />

Digital Operator/Monitor’s EEPROM failed.<br />

A low Inverter voltage has been detected.<br />

Retry the READ command (o3-01 = 1).<br />

Replace the Digital Operator/Monitor.<br />

CPE<br />

ID UNMATCHED<br />

The Inverter type or software number was different<br />

from the stored data in the digital operator<br />

Use stored data of the same product (L7) and software<br />

number (U1-14) only.<br />

VAE<br />

INV. KVA UNMATCH<br />

The capacity of the Inverter and the capacity of<br />

the stored data in the Digital Operator/Monitor are<br />

different.<br />

Use stored data for the same Inverter capacity<br />

only (o2-04).<br />

COPY<br />

Function<br />

CRE<br />

CONTROL<br />

UNMATCHED<br />

The control method of the Inverter and the control<br />

method of the stored data in the Digital Operator/<br />

Monitor are different.<br />

Use stored data for the same control<br />

method (A1-02).<br />

CYE<br />

COPY ERROR<br />

A parameter setting written to the Inverter was<br />

different from the setting stored in the Digital<br />

Operator/Monitor.<br />

Retry the COPY function (o3-01 = 2)<br />

CSE<br />

SUM CHECK ERROR<br />

Upon completion of the COPY function, the<br />

Inverter’s data checksum was different than the<br />

digital operator’s data checksum.<br />

Retry the COPY function (o3-01 = 2)<br />

Verify<br />

Function<br />

VYE<br />

VERIFY ERROR<br />

The set value of the digital operator and the<br />

Inverter do not match<br />

Retry the Verify function (o3-01 = 3)<br />

6-14