Control Sequence<br />

Speed Reference Source Selection<br />

•Speed Reference Source Selection<br />

The speed reference source can be selected using parameter b1-01.<br />

Related Parameters<br />

Parameter<br />

No.<br />

Name<br />

Factory<br />

Setting<br />

Change<br />

during<br />

Operation<br />

V/f<br />

Control Methods<br />

Open<br />

Loop<br />

Vector<br />

b1-01 Frequency reference source selection 0 No Q Q Q<br />

Closed<br />

Loop<br />

Vector<br />

Input the Speed Reference from the Digital Inputs (b1-01=0)<br />

When b1-01 is set to 0 the speed reference can be selected from preset speeds using the digital inputs of the<br />

inverter. Refer to page 5-6, Speed Selection Sequence Using Digital Inputs for details.<br />

Input the Speed Reference Using a Voltage Signal (b1-01=1)<br />

When b1-01 is set to 1 and H3-15 (Input function for A1) is set to 0 (Frequency reference) the speed reference<br />

can be input by the terminal A1 as a 0 to +10V signal. If an analog option card AI-14B is installed, the A1 signal<br />

is replaced by the Channel 1 input of the AI card.<br />

The analog reference signal can be used as well as 1st speed if multispeed operation is selected (Refer to page<br />

5-6, Speed Selection Sequence Using Digital Inputs for details)<br />

5<br />

Input the Speed Reference Using Memobus Communications (b1-01=2)<br />

When b1-01 is set to 2 the speed reference can be input using Memobus communications.<br />

Input the Speed Reference Using an Input Option Card (b1-01=3)<br />

When b1-01 is set to 2 the speed reference can be input using an input option card, for example a field bus<br />

communications card.<br />

5-5