Note: 1. When changing the display with the Increment / Decrement keys, the next display after the one for the last parameter number will be the one for the<br />

first parameter number and vice versa. For example, the next display after the one for U1-01 will be U1-55. This is indicated in the figures by the letters<br />

A and B and the numbers 1 to 6.<br />

2. The display for the first monitor parameter (frequency reference) will be displayed when power is turned ON. The monitor item displayed at startup<br />

can be set in o1-02 (Monitor Selection after Power Up).Operation cannot be started from the mode selection display.<br />

Quick Programming Mode<br />

In quick programming mode, the basic parameters required for the elevator operation like speeds, acceleration/deceleration<br />

times etc. can be monitored and set.<br />

The parameters can be changed from the setting displays. Use the Increment, Decrement, and Shift/RESET<br />

keys to change the frequency. The parameter will be written and the monitor display will be returned to when<br />

the DATA/ENTER key is pressed after changing the setting.<br />

Refer to Chapter 4, User Parameters for details on the parameters displayed in quick programming mode.<br />

•Example Operations<br />

Example key operations in quick programming mode are shown in the following figure.<br />

Mode Selection Display<br />

Monitor Display<br />

Setting Display<br />

MENU<br />

-DRIVE-<br />

** Main Menu **<br />

Operation<br />

MENU<br />

A<br />

B<br />

-QUICK-<br />

** Main Menu **<br />

Quick Setting<br />

ESC<br />

-QUICK-<br />

Control Method<br />

A1-02 = 0 *0*<br />

V/f Control<br />

"0"<br />

ESC<br />

-QUICK-<br />

Control Method<br />

A1-02 = 0 *0*<br />

V/f Control<br />

"0"<br />

MENU<br />

-ADV-<br />

** Main Menu **<br />

Programming<br />

-QUICK-<br />

Accel Time 1<br />

C1-01 = 1.50sec<br />

(0.00 ~ 600.00)<br />

"1.50"<br />

ESC<br />

-QUICK-<br />

Accel Time 1<br />

C1-01 =001.50sec<br />

(0.00 ~ 600.00)<br />

"1.50"<br />

MENU<br />

-VERIFY-<br />

** Main Menu **<br />

-QUICK-<br />

Decel Time 1<br />

C1-01 = 1.50sec<br />

(0.00 ~ 600.00)<br />

"1.50"<br />

ESC<br />

-QUICK-<br />

Decel Time 1<br />

C1-01 =001.50sec<br />

(0.00 ~ 600.00)<br />

"1.50"<br />

Modified Consts<br />

MENU<br />

-A.TUNE-<br />

** Main Menu **<br />

ESC<br />

-QUICK-<br />

Mtr Rated Power<br />

E2-11 = 4.00kW<br />

(0.00 ~ 650.00)<br />

"4.00kW"<br />

-QUICK-<br />

Mtr Rated Power<br />

E2-11 = 004.00kW<br />

(0.00 ~ 650.00)<br />

"4.00kW"<br />

Auto-Tuning<br />

-QUICK-<br />

MOL Fault Select<br />

L1-01=1 *1*<br />

Std Fan Cooled<br />

"1"<br />

ESC<br />

-QUICK-<br />

MOL Fault Select<br />

L1-01 = 1 *1*<br />

Std Fan Cooled<br />

"1"<br />

A<br />

B<br />

Fig 3.26 Operations in Quick Programming Mode<br />

3-8