Acceleration and Deceleration Characteristics<br />
Acceleration and Deceleration Characteristics<br />
Setting Acceleration and Deceleration Times<br />
The acceleration time indicates the time to increase the speed from 0% to 100% of the maximum speed set in<br />
E1-04. The deceleration time indicates the time to decrease the speed from 100% to 0% of E1-04.<br />
Four separate acceleration and deceleration times can be set. It can be switched over between them<br />
• using digital input signals<br />
• using the automatic accel./decel. time switch over function with a changeable switching speed level<br />
The display unit and the setting range for the times can be selected between 0.0 sec. or 0.00sec.<br />
•Related Parameters<br />
Parameter<br />
No.<br />
Name<br />
Factory<br />
Setting<br />
Change<br />
during<br />
Operation<br />
V/f<br />
Control Methods<br />
Open<br />
Loop<br />
Vector<br />
C1-01 Acceleration time 1<br />
Yes Q Q Q<br />
C1-02 Deceleration time 1 Yes Q Q Q<br />
C1-03 Acceleration time 2 Yes A A A<br />
C1-04 Deceleration time 2 Yes A A A<br />
1.5 sec<br />
C1-05 Acceleration time 3 No A A A<br />
C1-06 Deceleration time 3 No A A A<br />
C1-07 Acceleration time 4 No A A A<br />
C1-08 Deceleration time 4 No A A A<br />
C1-10 Acceleration/deceleration time setting unit 1 No A A A<br />
C1-11 Deceleration time switching frequency 0.0 Hz No Q Q Q<br />
S1-26 Dwell at start speed reference 0.0 Hz No A A A<br />
Closed<br />
Loop<br />
Vector<br />
5<br />
Multi-function Digital Inputs (H1-01 to H1-05)<br />
Set<br />
Value<br />
Function<br />
Control Methods<br />
Open Closed<br />
V/f Loop<br />
Vector<br />
Loop<br />
Vector<br />
7 Acceleration/Deceleration switch over 1 Yes Yes Yes<br />
1A Acceleration/Deceleration switch over 2 Yes Yes Yes<br />
•Setting Acceleration and Deceleration Time Units<br />
Set the acceleration/deceleration time units using C1-10. The factory setting is 1.<br />
Set value<br />
Details<br />
0 The acceleration/deceleration time setting range is 0.00 to 6000.0 in units of 0.01 s.<br />
1 The acceleration/deceleration time setting range is 0.00 to 600.00 in units of 0.1 s.<br />
5-17