9–14 Chapter 9: Assembler Assignments<br />

ENABLE_OCT_DONE<br />

ENABLE_OCT_DONE<br />

Type<br />

This option controls whether the INIT_DONE signal is gated by the OCT_DONE signal<br />

which indicates the Power-Up OCT calibration is completed. If this option is turned<br />

off, the INIT_DONE signal is not gated by the OCT_DONE signal.<br />

Boolean<br />

Device Support<br />

This setting can be used in projects targeting the following device families:<br />

■ Arria <strong>II</strong> GX<br />

■ Arria V<br />

■ Cyclone <strong>II</strong>I<br />

■ Cyclone <strong>II</strong>I LS<br />

■ Cyclone IV E<br />

■ Cyclone IV GX<br />

■ Cyclone V<br />

■ Stratix V<br />

Notes<br />

This assignment is included in the Fitter report.<br />

Syntax<br />

set_global_assignment -name ENABLE_OCT_DONE <br />

Default Value<br />

Off<br />

<strong>Quartus</strong> <strong>Settings</strong> <strong>File</strong> June 2012 <strong>Altera</strong> Corporation<br />