6–26 Chapter 6: Fitter Assignments<br />

AUTO_TURBO_BIT<br />

AUTO_TURBO_BIT<br />

Type<br />

Controls the speed versus power usage trade-off for a macrocell. If you set the Turbo<br />

Bit option to on, the speed of the macrocell increases; if you set this option to Off, its<br />

power consumption decreases; if you choose the Auto setting, the Compiler chooses<br />

the most appropriate setting for the design.<br />

Enumeration<br />

■ Auto<br />

■ Off<br />

■ On<br />

Device Support<br />

This setting can be used in projects targeting the following device families:<br />

■ MAX3000A<br />

■ MAX7000A<br />

■ MAX7000AE<br />

■ MAX7000B<br />

■ MAX7000S<br />

Notes<br />

This assignment is included in the Analysis & Synthesis report.<br />

Syntax<br />

set_global_assignment -name AUTO_TURBO_BIT <br />

set_global_assignment -name AUTO_TURBO_BIT -entity <br />

set_instance_assignment -name AUTO_TURBO_BIT -to -entity <br />

Default Value<br />

On<br />

<strong>Quartus</strong> <strong>Settings</strong> <strong>File</strong> June 2012 <strong>Altera</strong> Corporation<br />

<strong>Reference</strong> <strong>Manual</strong>