100<br />

PANELBOARDS<br />

General Information<br />

ORIGINAL WESTINGHOUSE PANELBOARD BREAKER REPLACEMENT CHART<br />

Westinghouse<br />

Existing Branch Circuit Breaker REPLACEMENT SOLUTIONS<br />

Panelboard Type<br />

New Panelboard<br />

Type<br />

Panelboards Manufactured Between 1937 and 1988<br />

ABH➋<br />

E<br />

PRL3a<br />

—<br />

A2B➋<br />

E<br />

PRL3a<br />

—<br />

B10B➋<br />

BA<br />

PRL1a<br />

BAB<br />

B10B-LX➋<br />

BA<br />

PRL1aLX<br />

BAB<br />

B10B-LXX➋<br />

BA<br />

PRL1aLX<br />

BAB<br />

B65B➋<br />

HBA<br />

PRL1a<br />

—<br />

CDP/HCDP➋<br />

E, EA, EH<br />

PRL4B<br />

—<br />

F, FA<br />

—<br />

CDP/HCDP➌<br />

EB, EHB, EHD, FB,<br />

PRL4B EHD<br />

HFB, FDB, FD, HFD, FDC<br />

FDB, FD, HFD, FDC<br />

FB-P TRI-PAC<br />

JB, KB, HKB, JDB,<br />

JD, HJD, JDC<br />

CA, CAH, HCA<br />

DA, LB, LBB, HLB➍<br />

JA, KA, HKA, DK,<br />

KD, HKD, KDC<br />

LA, LAB, HLA (400A)<br />

LA-P TRI-PAC<br />

LA, LC, HLA (600A)<br />

MA, HMA, MC, HMC<br />

LCL<br />

NB, HNB, NC, HNC<br />

NB-P TRI-PAC<br />

New Breaker Panelboard<br />

Replacement Breaker➊<br />

FB-P TRI-PAC<br />

JDB<br />

JD, HJD, JDC<br />

ED, EDH, EDC<br />

➍<br />

DK,<br />

KD, HKD, KDC<br />

LD, HLD<br />

LA-P TRI-PAC<br />

LD, HLD, LDC<br />

MDS<br />

LCL<br />

ND, HND<br />

NB-P TRI-PAC<br />

RE<br />

RE<br />

—<br />

—<br />

—<br />

HBAW, HBAX<br />

RE, REA, REH<br />

RF, RFA<br />

Contact your local<br />

Cutler-Hammer<br />

Field Sales Office.<br />

FDP Fusible Switches PRL4F Fusible Switches<br />

H10P➋<br />

HQP<br />

PRL2a<br />

HQP<br />

H10B➋<br />

BA<br />

PRL2a<br />

BAB<br />

NAB➋<br />

E<br />

PRL3a<br />

RE<br />

NAIB➋<br />

E<br />

PRL3a<br />

RE<br />

NDP➋<br />

E, EA, EAH<br />

PRL3a<br />

RE, REA, REH<br />

NEB➋<br />

EA<br />

PRL3a<br />

REA<br />

NHDP➋<br />

EH<br />

PRL3a<br />

REH<br />

NHEB➋<br />

EH, FA<br />

PRL3a<br />

REH, RFA<br />

NHIB➋<br />

E-277<br />

PRL2a<br />

RE<br />

NLAB➋<br />

QC<br />

PRL1a<br />

—<br />

NLAB-LX➋<br />

QC<br />

PRL1aLX<br />

—<br />

NLAB-AB➋<br />

QC<br />

PRL3a<br />

—<br />

NLAB-ABH➋<br />

QC<br />

PRL3a<br />

—<br />

NPLAB➋<br />

QP<br />

PRL1a<br />

HQP<br />

NPLAPQ➋<br />

QP<br />

PRL1a<br />

HQP<br />

NQC➋<br />

QC<br />

PRL1a<br />

—<br />

➊ Not Rated for 100% rated <strong>breakers</strong>.<br />

➋ Connectors not available.<br />

➌ Only <strong>breakers</strong> of the same frame size can be installed across from each other (i.e. in the same horizontal plane).<br />

For other configurations, call 1-800-556-4569.<br />