SWITCHGEAR (MEDIUM VOLTAGE)<br />

DHP Switchgear Assemblies,<br />

Power Circuit Breakers, and Renewal Parts<br />

PRODUCT HISTORY<br />

March 2001<br />

Low Resolution Photo<br />

Type DHP Drawout Air Magnetic Power Circuit<br />

Breaker (Front Interphase Barrier Removed)<br />

REPLACEMENT CAPABILITIES<br />

150DHP-VR500 1200 Ampere Vacuum Replacement<br />

Breaker for DHP Switchgear<br />

Westinghouse DHP medium voltage<br />

porcel-line metal-clad switchgear with<br />

type DHP air magnetic power <strong>circuit</strong><br />

<strong>breakers</strong> was introduced in 1963. DHP<br />

<strong>breakers</strong> and switchgear were similar to,<br />

but not interchangeable with, the older<br />

DH product. DHP was provided with<br />

porcelain insulation on all live parts to<br />

ground in the switchgear and on the<br />

breaker element. DHP switchgear was<br />

available in indoor and in sheltered aisle<br />

and aisle-less outdoor enclosures.<br />

DHP air magnetic <strong>breakers</strong> were subject to<br />

three major design changes that were<br />

phased in during their manufacturing life.<br />

The first DHP <strong>breakers</strong> were furnished<br />

with solenoid operated mechanisms with<br />

cast parts and monolithic pole units. From<br />

1964 to 1968, the stored energy spring<br />

mechanism gradually phased out the<br />

solenoid operator. After 1968, cast mechanisms<br />

were phased out by fabricated<br />

mechanisms. After 1970, monolithic pole<br />

Cutler-Hammer offers an extensive<br />

amount of products to support DHP<br />

switchgear.<br />

DHP Match and Lineup Cubicles<br />

New manufactured DHP switchgear structures<br />

to match and line up to existing<br />

Westinghouse DHP switchgear are available<br />

in indoor and in outdoor sheltered<br />

aisle and aisle-less enclosure construction.<br />

DHP-VR Vacuum Replacement Breakers<br />

The DHP-VR is a brand new direct roll-in<br />

replacement vacuum breaker for DHP air<br />

magnetic and DVP vacuum <strong>breakers</strong>. The<br />

DHP-VR breaker permits DHP switchgear<br />

modernization by using state-of-the-art<br />

Cutler-Hammer VCP-W vacuum breaker<br />

technology. The DHP-VR is factory<br />

designed and manufactured with complete<br />

factory and ANSI design testing.<br />

New DHP Air Magnetic Breakers<br />

Completely new factory manufactured<br />

DHP air magnetic power <strong>circuit</strong> <strong>breakers</strong><br />

are still available in ratings from<br />

50DHP250 1200 ampere to 150DHP1000<br />

3000 ampere.<br />

Remanufactured DHP Breakers and<br />

Factory Repair Service<br />

Factory remanufacturing of DHP <strong>breakers</strong><br />

and factory repair service for DHP <strong>breakers</strong><br />

are available.<br />

Renewal Parts<br />

Cutler-Hammer offers an extensive inventory<br />

of newly manufactured renewal parts<br />

for DHP switchgear structures and <strong>breakers</strong>.<br />

277<br />

units were phased out by the postinsulator<br />

pole unit (PIP) design.<br />

DVP vacuum <strong>breakers</strong> were introduced in<br />

1978. DVP <strong>breakers</strong> were first generation<br />

vacuum <strong>breakers</strong> that were interchangeable<br />

in DHP switchgear with DHP air<br />

magnetic <strong>breakers</strong> of the same ratings.<br />

Ratings<br />

DHP Breakers: 5 kV (75, 250 and<br />

350 MVA)<br />

7.5 kV (500 MVA)<br />

15 kV (500, 750 and<br />

1000 MVA)<br />

DVP Breakers: 7.5 kV (500 MVA) and<br />

15 kV (500 and 750 MVA)<br />

Chronology<br />

DHP switchgear was introduced in<br />

1963 and was actively manufactured by<br />

Westinghouse in complete switchgear<br />

assemblies until 1984.<br />