TECHNOLOGY UPGRADES, Continued<br />

LF Starter Retrofit Kits<br />

Front View<br />

400A Air to Vacuum Contactor Retrofit Kit<br />

This kit is for retrofitting an existing 400A<br />

LF air contactor with the directly interchangeable<br />

400A SJA contactor.<br />

Refer to RPD 8855V for further<br />

information.<br />

Complete contactor 2300/120V, 750VA<br />

transformer.<br />

Style No. 2147A45G01<br />

Complete contactor 2300/120V, 2 kVA<br />

transformer.<br />

Style No. 2147A45G02<br />

Complete contactor 4160/120V, 600VA<br />

transformer.<br />

Style No. 2147A45G03<br />

Complete contactor 4160/120V, 2 kVA<br />

transformer.<br />

Style No. 2147A45G04<br />

March 2001<br />

STARTERS (MEDIUM VOLTAGE)<br />

LF Air AMPGARD Assemblies,<br />

Retrofit Kits and Renewal Parts<br />

Drawout Design<br />

400A Air to Vacuum Starter Retrofit Kit<br />

Complete full voltage, non-reversing,<br />

induction, vacuum AMPGARD motor<br />

starter, 400A, 7200V max., for mounting in<br />

existing 36-inch wide enclosure. Includes<br />

main contactor, isolation switch, three<br />

power fuses, IQ 1000 II motor protection<br />

without RTD module, (3) current<br />

transformers, vertical bus, high and low<br />

voltage doors, and welded cell assembly<br />

for mounting in existing 36-inch wide<br />

enclosure.<br />

Refer to RPD 8855C for more details.<br />

Style No. 2147A95G01 (Slideout)<br />

Style No. 2147A95G02 (Rollout)<br />

Picture<br />

not<br />

Available<br />

Low Resolution Photo<br />

Picture<br />

not<br />

Available<br />

205<br />

700A Air to Vacuum Conversion Kit<br />

This kit will convert an existing fullvoltage<br />

non-reversing 700A air break<br />

starter to vacuum rated, either 450A maximum<br />

full-load current or 720A maximum<br />

full-load current.<br />

Refer to RPD 8855C for more details.<br />

Style No. 2147A95G31 450-630A max.<br />

Style No. 2147A95G32 720A max.<br />

50L2 Air-to-Vacuum Retrofit Kit<br />

This kit replaces the out-of-production<br />

5000 volt, 200 ampere air break contactor<br />

with an SJ vacuum contactor, for starters<br />

built after 1974 with Iso-Switch shutter<br />

mechanism mounted in the cell. The customer<br />

keeps the existing starter cell and<br />

isolation switch and modifies the cell to<br />

accept the SJ contactor which is mechanically<br />

interlocked with the isolation switch.<br />

The rating remains 200 ampere.<br />

Refer to RPD 8855C for more details.<br />

Style No. 2147A95G30 200A max.<br />

Contact your local Cutler-Hammer Field<br />

Sales Office for 320 ampere design and<br />

pre-1974 50L2 retrofit kits.<br />

N