CATALOG NUMBER<br />

Trip Unit Type<br />

5 510 Basic➊<br />

March 2001<br />

SWITCHGEAR (TRIP UNIT RETROFIT KITS)<br />

Digitrip RMS Retrofit Kits for Westinghouse<br />

SPB Breakers<br />

Protection<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

LI<br />

LSI<br />

LS<br />

LIG➋<br />

LSG➋<br />

LSIG➋<br />

T Digitrip 510<br />

N Standard Kit<br />

W 5 8 5 6 6 8 8 N S - T N N N<br />

N Standard Kit<br />

N Standard Kit<br />

N No Sensors<br />

RP No Rating Plug<br />

N<br />

6<br />

No Rating Plug<br />

50/60 Hz Plug<br />

Cat.<br />

Code<br />

Current Rating<br />

Tap Plug<br />

21 200 100<br />

22 200 200<br />

Code Breaker Frame Description Breaker Frame Rating and Sensor Tap<br />

32<br />

3Q<br />

300<br />

300<br />

200<br />

250<br />

W34 SPB-50-400 400<br />

33 300 300<br />

W38 SPB-50-800 800<br />

42 400 200<br />

W4T<br />

W4C<br />

SPB-65-1200<br />

SPB-65-1600<br />

1200<br />

1600<br />

4Q<br />

43<br />

44<br />

400<br />

400<br />

400<br />

250<br />

300<br />

400<br />

W4E SPB-65-2000 Compact 2000C<br />

63 600 300<br />

W54<br />

W58<br />

SPB-100-400<br />

SPB-100-800<br />

400<br />

800<br />

64<br />

66<br />

600<br />

600<br />

400<br />

600<br />

W5T<br />

W5C<br />

SPB-100-1200<br />

SPB-100-1600<br />

1200<br />

1600<br />

84<br />

86<br />

88<br />

800<br />

800<br />

800<br />

400<br />

600<br />

800<br />

W5D SPB-100-2000 2000<br />

T6 1200 600<br />

W5E SPB-100-2000 Compact 2000C<br />

T8 1200 800<br />

W5P<br />

W5H<br />

W5K<br />

SPB-100-2500<br />

SPB-100-3000<br />

SPB-100-4000<br />

2500<br />

3000<br />

4000<br />

TA<br />

TT<br />

C8<br />

CA<br />

1200<br />

1200<br />

1600<br />

1600<br />

1000<br />

1200<br />

800<br />

1000<br />

W5L SPB-100-5000 5000<br />

CT 1600 1200<br />

W64 SPB-150-400 400<br />

CC 1600 1600<br />

W68<br />

W6T<br />

SPB-150-800<br />

SPB-150-1200<br />

800<br />

1200<br />

DA<br />

DT<br />

DC<br />

2000<br />

2000<br />

2000<br />

1000<br />

1200<br />

1600<br />

W6C SPB-150-1600 1600<br />

DD 2000 2000<br />

W6D SPB-150-2000 2000<br />

EA 2000C 1000<br />

W6E<br />

W6P<br />

SPB-150-2000 Compact<br />

SPB-150-2500<br />

2000C<br />

2500<br />

ET<br />

EC<br />

EE<br />

2000C<br />

2000C<br />

2000C<br />

1200<br />

1600<br />

2000<br />

W6H SPB-150-3000 3000<br />

PC 2500 1600<br />

W6K SPB-150-4000 4000<br />

PD 2500 2000<br />

W6L SPB-150-5000 5000<br />

PP 2500 2500<br />

HC 3000 1600<br />

This information is subject to change.<br />

Updated pricing and availability information<br />

resides on Fred II. (412-937-6400)<br />

NOTE: At the time of this publication,<br />

the standard trip units for Low<br />

Voltage Digitrip Retrofit Kits<br />

HD<br />

HP<br />

HH<br />

KD<br />

3000<br />

3000<br />

3000<br />

4000<br />

2000<br />

2500<br />

3000<br />

2000<br />

are the RMS 510/610/810/910.<br />

KP 4000 2500<br />

KH 4000 3000<br />

KJ 4000 3200<br />

KK 4000 4000<br />

LH 5000 3000<br />

LJ 5000 3200<br />

LK 5000 4000<br />

LL 5000 5000<br />

➊ Digitrip 610, 810, and 910 are not available for SPB Breaker Retrofit Kits. A factory upgrade program is available.<br />

Call factory for more information at 1-800-222-9773.<br />

➋ SPB Breakers supplied from factory without ground fault (G) cannot be retrofitted in the field to include ground fault.<br />

261<br />

S

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!