200<br />

STARTERS (MEDIUM VOLTAGE)<br />

General Information<br />

GENERAL INFORMATION, Continued<br />

Old Catalog System – Contactors Only<br />

LF – Air Break<br />

SJ – Vacuum<br />

25 – 2500V<br />

33 – 3300V<br />

50 – 5000V<br />

72 – 7200V<br />

Current Catalog System – Contactors Only<br />

Vacuum<br />

Break<br />

A – Drawout Use<br />

O – OEM Design<br />

S – Slideout<br />

25 – 2500V<br />

50 – 5000V<br />

72 – 7200V<br />

Vacuum Break<br />

LF 25 H 4 3 0<br />

S J A 5 0 V W 4 3 0<br />

Old Catalog System – Starters (with Isolating Switch, Power Fuses, Contactor, etc.)<br />

10 – Manual<br />

11 – Magnetic<br />

13 – Wound Rotor<br />

14 – Synchronous<br />

17 – Air Conditioning<br />

2 – Full Voltage<br />

3 – Solid State<br />

4 – Resistor<br />

5 – Reactor<br />

6 – R.V. Auto-transformer<br />

7 – R.V. Part Winding<br />

8 – R.V. Wye-Delta<br />

9 – F.V. Multispeed<br />

0 – Non-Reversing<br />

1 – Reversing<br />

11 – 2 0 2 – 25 L 2<br />

Current Catalog System – Starters (with Isolating Switch, Power Fuses, Contactors, etc.)<br />

H – Air Break (Obsolete)<br />

V – Vacuum Break “Drawout”<br />

S – Vacuum Break “Slideout”<br />

Type of Starter<br />

202 – FV Non-Reversing<br />

212 – FV Reversing<br />

502 – Reactor<br />

602 – Autotransformer<br />

702 – Part Winding<br />

802 – Wye-Delta<br />

902 – Multispeed<br />

S 2 0 2 S 4 G<br />

Enclosure<br />

S – NEMA 1<br />

A – NEMA 1A<br />

J – NEMA 12<br />

R – NEMA 3<br />

Normally Closed Poles<br />

Normally Open Poles<br />

2 – 200A<br />

4 – 400A<br />

7 – 700A<br />

8 – 800A<br />

H – Air Break<br />

V – Vacuum<br />

J – Vacuum<br />

Normally<br />

Closed Poles<br />

Normally<br />

Opened Poles<br />

4 – 400A<br />

8 – 800A<br />

W – [ Bottle<br />

M – Metric Bottle<br />

(Obsolete)<br />

2 – 200A<br />

4 – 400A<br />

7 – 700A<br />

8 – 800A<br />

L – Air Break<br />

V – Vacuum<br />

J – Vacuum<br />

25 – 2500V<br />

33 – 3300V<br />

50 – 5000V<br />

72 – 7200V<br />

2 – Non-Load Break, Fused Switch<br />

1 – Non-Load Break, Non-Fused Switch<br />

Voltage Class<br />

E – 2400V, 60 Hz<br />

G – 4160V, 60 Hz<br />

K – 6900V, 60 Hz<br />

L – 3300V, 60 Hz<br />

Contactor Ampere Rating<br />

2 – 200A<br />

4 – 400A<br />

7 – 700A<br />

8 – 800A<br />

March 2001