106<br />

PANELBOARDS<br />

General Information<br />

PRL3 PRL3a<br />

Originally a Westinghouse Product<br />

No Neutral<br />

Neutral Section<br />

Sub Chassis<br />

400 Amp Maximum<br />

Bus Rating<br />

1-Pole<br />

2-Pole<br />

1-Pole<br />

2-Pole<br />

2- and 3-Pole<br />

Main<br />

Breaker<br />

Section<br />

Main Lug<br />

Section<br />

Westinghouse PRL3<br />

1-Pole<br />

2-Pole<br />

3-Pole<br />

Horizontal<br />

Mounting<br />

Vertically<br />

Mounted<br />

Panel Layout<br />

2X 100-600A<br />

2X 100, 225A<br />

8X 400, 600A<br />

Poles<br />

10X-12<br />

13X-18<br />

15X-24<br />

17X-30<br />

19X-36<br />

21X-42<br />

1X<br />

BAB➊➋<br />

QBH➊<br />

GB➌➍<br />

GHB➌➍<br />

EHD (100A Max.)<br />

2X<br />

FDB<br />

FD<br />

HFD<br />

(150A Max.)<br />

3X FDC<br />

3X CA, CAH, HCA➎<br />

(225A Max.)<br />

2X 100, 225A<br />

7X 400, 600A<br />

(100A Max.)<br />

3X 2P EHD (100A Max.)➏<br />

3X 2P FDB, FD, HFD, FDC➏<br />

(150A Max.)<br />

4X 3P EHD (100A Max.)➏<br />

4X 3P FDB, FD, HFD, FDC<br />

(150A Max.)➏<br />

4X 2P & 3P CA, CAH, HCA➏<br />

(225A Max.)<br />

7X EHD (100A Max.)<br />

7X FDB, FD, HFD, FDC<br />

(150A Max.)<br />

9X CA, CAH<br />

(225A Max.)<br />

9X FCL, FB-P➐<br />

(100A Max.)<br />

14X JD, JDB, HJD, JDC<br />

(250A Max.)<br />

14X DK, KD, KDB, HKD,<br />

KDC (400A Max.)<br />

19X LC, HLC, LA<br />

(600A Max.)<br />

22X LCL➑, LA-P➒<br />

(400A Max.)<br />

Refer to RPD 31-490 for more information on the Westinghouse<br />

Pow-R-Line 3.<br />

➊ If panel contains only BAB or QBH branch <strong>breakers</strong>, use a PRL1 panelboard.<br />

➋ BAB and QBH <strong>breakers</strong> with shunt trips require one additional pole space,<br />

i.e.; 1-pole is 2-pole size, 2-pole is 3-pole size and 3-pole is 4-pole size.<br />

➌ GB, GHB <strong>breakers</strong> cannot be mixed on same subchassis as BAB, QBH.<br />

➍ If panel contains only GB or GHB branch <strong>breakers</strong>, use a PRL2 panelboard.<br />

➎ Not recommended for motor loads. Use JD <strong>circuit</strong> breaker.<br />

Main Lugs<br />

4.01" 4.01"<br />

Neutral<br />

2P<br />

10.00" 3.92"<br />

3P<br />

(1) – 1P<br />

(2) – 1P<br />

(1) – 1P<br />

(2) – 1P<br />

3.92"<br />

(3) – 1P (3) – 1P 3.92"<br />

(3) – 1P (1) – 3P<br />

(1) – 1P<br />

(1) – 2P<br />

(1) – 3P<br />

2P<br />

2P<br />

3P<br />

3P<br />

4.01"<br />

Split Bus<br />

Meter Loop<br />

ASCO<br />

920<br />

(Split Bus)<br />

Quicklag<br />

4.01"<br />

BAB – 5.70" BAB – 5.70"<br />

GHB – 5.68" GHB – 5.68"<br />

4.01"<br />

GHB<br />

Twin<br />

Subfeed<br />

Breaker<br />

Single Subfeed<br />

Breaker<br />

Through Feed<br />

Lugs<br />

4.01"<br />

Panel Layout<br />

Cutler-Hammer/<br />

Westinghouse PRL3a<br />

2X<br />

5X<br />

2X<br />

5X<br />

6X<br />

6X<br />

8X<br />

10X<br />

8X<br />

10X<br />

5X<br />

8X<br />

11X<br />

2X<br />

3X<br />

1X<br />

2X<br />

3X<br />

3X<br />

3X<br />

2X<br />

3X<br />

X<br />

12X<br />

19X<br />

16X<br />

3X<br />

5X<br />

8X<br />

10X<br />

20X<br />

X<br />

X<br />

100A Std #14-1/0<br />

100A Oversized #6-350MCM<br />

100A Subfeed (2) #14-1/0<br />

250A Std #6-350MCM<br />

250A Oversized 4/0-500MCM<br />

250A Subfeed (2) #6-350MCM<br />

400A Std (2) 4/0-500MCM<br />

400A Oversized (2) 3/0-750MCM<br />

600A Std (2) 4/0-500MCM<br />

600A Oversized (2) 3/0-750MCM<br />

Same Cable Size as MLO<br />

ED, EDH, EDC 225A Max.<br />

NOTE:<br />

Line Side May Be Either Left or<br />

Right. Distance From Load Side of<br />

Breaker To Box Will Always Be 3.92 in.<br />

EHD 100A Max.<br />

FD, HFD, FDC, FDB 150A Max.<br />

Same Cable Size as MLO<br />

Bus Connected ASCO 920 (30A-225A)<br />

Cable Connected 225A Max. For Lug Size See Main<br />

(Wireout)<br />

100A Max. Lug Size Chart.<br />

6 Ckt.<br />

12 Ckt.<br />

18 Ckt.<br />

24 Ckt.<br />

BAB, QBGF, QBHW, QBHGF 100A Max.<br />

or<br />

GB, GHB 100A Max.<br />

NOTE:<br />

May Have Multiple Sections<br />

Per Panel, Max. 24 Ckts. Per<br />

Section.<br />

JD, JDB, HJD, JDC, 250A Max.<br />

Size Per Main Breaker Layout<br />

Size Per MLO Size Chart<br />

Not Available With Subfeed Breaker<br />

Refer to RPD 31-490 for more information on the Cutler-Hammer/<br />

Westinghouse Pow-R-Line 3a.<br />

➏ Horizontally mounted 15 through 150 ampere main <strong>breakers</strong> EHD, FDB, FD,<br />

HFD, FDC, will be furnished as branch breaker construction. Branch <strong>breakers</strong><br />

1, 2 or 3 poles as required, may be located opposite these main <strong>breakers</strong>.<br />

➐ FBP and LAP top mounting only.<br />

➑ 100% rated breaker.<br />

➒ LCL main breaker requires 6-1/2-inch deep box.<br />

March 2001