PANELBOARDS<br />
General Information<br />
PRL3 PRL3a<br />
Originally a Westinghouse Product<br />
No Neutral<br />
Neutral Section<br />
Sub Chassis<br />
400 Amp Maximum<br />
Bus Rating<br />
1-Pole<br />
2-Pole<br />
1-Pole<br />
2-Pole<br />
2- and 3-Pole<br />
Main<br />
Breaker<br />
Section<br />
Main Lug<br />
Section<br />
Westinghouse PRL3<br />
1-Pole<br />
2-Pole<br />
3-Pole<br />
Horizontal<br />
Mounting<br />
Vertically<br />
Mounted<br />
Panel Layout<br />
2X 100-600A<br />
2X 100, 225A<br />
8X 400, 600A<br />
Poles<br />
10X-12<br />
13X-18<br />
15X-24<br />
17X-30<br />
19X-36<br />
21X-42<br />
1X<br />
BAB➊➋<br />
QBH➊<br />
GB➌➍<br />
GHB➌➍<br />
EHD (100A Max.)<br />
2X<br />
FDB<br />
FD<br />
HFD<br />
(150A Max.)<br />
3X FDC<br />
3X CA, CAH, HCA➎<br />
(225A Max.)<br />
2X 100, 225A<br />
7X 400, 600A<br />
(100A Max.)<br />
3X 2P EHD (100A Max.)➏<br />
3X 2P FDB, FD, HFD, FDC➏<br />
(150A Max.)<br />
4X 3P EHD (100A Max.)➏<br />
4X 3P FDB, FD, HFD, FDC<br />
(150A Max.)➏<br />
4X 2P & 3P CA, CAH, HCA➏<br />
(225A Max.)<br />
7X EHD (100A Max.)<br />
7X FDB, FD, HFD, FDC<br />
(150A Max.)<br />
9X CA, CAH<br />
(225A Max.)<br />
9X FCL, FB-P➐<br />
(100A Max.)<br />
14X JD, JDB, HJD, JDC<br />
(250A Max.)<br />
14X DK, KD, KDB, HKD,<br />
KDC (400A Max.)<br />
19X LC, HLC, LA<br />
(600A Max.)<br />
22X LCL➑, LA-P➒<br />
(400A Max.)<br />
Refer to RPD 31-490 for more information on the Westinghouse<br />
Pow-R-Line 3.<br />
➊ If panel contains only BAB or QBH branch <strong>breakers</strong>, use a PRL1 panelboard.<br />
➋ BAB and QBH <strong>breakers</strong> with shunt trips require one additional pole space,<br />
i.e.; 1-pole is 2-pole size, 2-pole is 3-pole size and 3-pole is 4-pole size.<br />
➌ GB, GHB <strong>breakers</strong> cannot be mixed on same subchassis as BAB, QBH.<br />
➍ If panel contains only GB or GHB branch <strong>breakers</strong>, use a PRL2 panelboard.<br />
➎ Not recommended for motor loads. Use JD <strong>circuit</strong> breaker.<br />
Main Lugs<br />
4.01" 4.01"<br />
Neutral<br />
2P<br />
10.00" 3.92"<br />
3P<br />
(1) – 1P<br />
(2) – 1P<br />
(1) – 1P<br />
(2) – 1P<br />
3.92"<br />
(3) – 1P (3) – 1P 3.92"<br />
(3) – 1P (1) – 3P<br />
(1) – 1P<br />
(1) – 2P<br />
(1) – 3P<br />
2P<br />
2P<br />
3P<br />
3P<br />
4.01"<br />
Split Bus<br />
Meter Loop<br />
ASCO<br />
920<br />
(Split Bus)<br />
Quicklag<br />
4.01"<br />
BAB – 5.70" BAB – 5.70"<br />
GHB – 5.68" GHB – 5.68"<br />
4.01"<br />
GHB<br />
Twin<br />
Subfeed<br />
Breaker<br />
Single Subfeed<br />
Breaker<br />
Through Feed<br />
Lugs<br />
4.01"<br />
Panel Layout<br />
Cutler-Hammer/<br />
Westinghouse PRL3a<br />
2X<br />
5X<br />
2X<br />
5X<br />
6X<br />
6X<br />
8X<br />
10X<br />
8X<br />
10X<br />
5X<br />
8X<br />
11X<br />
2X<br />
3X<br />
1X<br />
2X<br />
3X<br />
3X<br />
3X<br />
2X<br />
3X<br />
X<br />
12X<br />
19X<br />
16X<br />
3X<br />
5X<br />
8X<br />
10X<br />
20X<br />
X<br />
X<br />
100A Std #14-1/0<br />
100A Oversized #6-350MCM<br />
100A Subfeed (2) #14-1/0<br />
250A Std #6-350MCM<br />
250A Oversized 4/0-500MCM<br />
250A Subfeed (2) #6-350MCM<br />
400A Std (2) 4/0-500MCM<br />
400A Oversized (2) 3/0-750MCM<br />
600A Std (2) 4/0-500MCM<br />
600A Oversized (2) 3/0-750MCM<br />
Same Cable Size as MLO<br />
ED, EDH, EDC 225A Max.<br />
NOTE:<br />
Line Side May Be Either Left or<br />
Right. Distance From Load Side of<br />
Breaker To Box Will Always Be 3.92 in.<br />
EHD 100A Max.<br />
FD, HFD, FDC, FDB 150A Max.<br />
Same Cable Size as MLO<br />
Bus Connected ASCO 920 (30A-225A)<br />
Cable Connected 225A Max. For Lug Size See Main<br />
(Wireout)<br />
100A Max. Lug Size Chart.<br />
6 Ckt.<br />
12 Ckt.<br />
18 Ckt.<br />
24 Ckt.<br />
BAB, QBGF, QBHW, QBHGF 100A Max.<br />
or<br />
GB, GHB 100A Max.<br />
NOTE:<br />
May Have Multiple Sections<br />
Per Panel, Max. 24 Ckts. Per<br />
Section.<br />
JD, JDB, HJD, JDC, 250A Max.<br />
Size Per Main Breaker Layout<br />
Size Per MLO Size Chart<br />
Not Available With Subfeed Breaker<br />
Refer to RPD 31-490 for more information on the Cutler-Hammer/<br />
Westinghouse Pow-R-Line 3a.<br />
➏ Horizontally mounted 15 through 150 ampere main <strong>breakers</strong> EHD, FDB, FD,<br />
HFD, FDC, will be furnished as branch breaker construction. Branch <strong>breakers</strong><br />
1, 2 or 3 poles as required, may be located opposite these main <strong>breakers</strong>.<br />
➐ FBP and LAP top mounting only.<br />
➑ 100% rated breaker.<br />
➒ LCL main breaker requires 6-1/2-inch deep box.<br />
March 2001