REPLACEMENT CAPABILITIES, Continued<br />

Special Breakers➊<br />

Type FB, Magnetic Only, Front Adjustable<br />

(Includes Line and Load Terminals)<br />

Continuous<br />

Ampere<br />

Rating<br />

3<br />

5<br />

10<br />

25<br />

25<br />

30<br />

30<br />

50<br />

50<br />

70<br />

100<br />

100<br />

150<br />

Accessories and Modifications<br />

Collar<br />

Conductor<br />

March 2001<br />

Magnetic<br />

Trip Range<br />

Amperes<br />

7 - 22<br />

15 - 45<br />

35 - 110<br />

32 - 80<br />

66 - 190<br />

50 - 150<br />

90 - 270<br />

66 - 190<br />

160 - 480<br />

100 - 270<br />

150 - 480<br />

450 - 1550<br />

575 - 1800<br />

Collar<br />

Nut<br />

Washer<br />

Conductor<br />

Screw<br />

MOLDED CASE CIRCUIT BREAKERS<br />

Replacement Circuit Breakers<br />

2-Pole➊➋,<br />

600 Volts AC 3-Pole, 600 Volts AC<br />

Standard MARK 75 Standard Saf-T-Vue MARK 75<br />

Catalog/Style Numbers<br />

FB2022MRL<br />

FB2045MRL<br />

FB2110MRL<br />

2610D53G12<br />

FB2190MRL<br />

1268C14G05<br />

FB2270MRL<br />

1268C14G01<br />

FB2480MRL<br />

2610D53G13<br />

1268C14G03<br />

FB21550MRL<br />

FB21800MRL<br />

Terminals<br />

Breakers include load terminals only➌➍.<br />

Terminals are Underwriters’ Laboratories,<br />

Inc. listed as suitable for wire type and<br />

size. When used with aluminum conductors,<br />

use joint compound. When line<br />

terminals are required, order by style<br />

number from table at no charge with the<br />

breaker.<br />

Style 624B100G02<br />

Insert collar enclosing<br />

conductor as shown.<br />

Locate nut on top of<br />

conductor and tighten<br />

securely with screw and<br />

washer. Caution: Collar<br />

must surround conductor.<br />

Style 624B100G10<br />

Assemble collar on<br />

top of conductor as<br />

shown. Tighten securely<br />

with screw and washer.<br />

LFB Current Limiter Attachment➐<br />

The LFB Current Limiter is an attachment<br />

that bolts to the load end of a standard FB<br />

thermal magnetic or magnetic only breaker,<br />

providing 200,000 Amperes Interrupting<br />

Capacity (AIC) at up to 600 volts AC.<br />

Limiters for thermal magnetic <strong>breakers</strong> are<br />

listed with Underwriters’ Laboratories, Inc.<br />

Current limiters must be applied as indicated<br />

in the table.<br />

Standard LFB terminals are suitable for<br />

Cu/AI cable. Ratings thru 70 amperes<br />

accept (1) #14-#2, and 100 and 150<br />

amperes accept (1) #1-4/0. ➑<br />

Max.<br />

Amperes<br />

Collar<br />

Washer<br />

Conductor<br />

Screw Extrusion<br />

HFB2022ML<br />

HFB2045ML<br />

HFB2110ML<br />

4994D96G12<br />

HFB2190ML<br />

. . . . . . . . . .<br />

HFB2270ML<br />

. . . . . . . . . .<br />

HFB2480ML<br />

4994D96G13<br />

. . . . . . . . . .<br />

HFB21550ML<br />

HFB21800ML<br />

Wire<br />

Type<br />

Style 624B100G17<br />

Clip<br />

Insert collar enclosing<br />

conductor and center on<br />

extrusion on collar. Install<br />

clip with legs on top of<br />

conductor and snap end<br />

around bottom of collar.<br />

Wire<br />

Range<br />

Standard Pressure Type Terminals<br />

20 (EB, EHB)<br />

100<br />

150<br />

Al/Cu<br />

Al/Cu<br />

Al/Cu<br />

#14-#10<br />

#14-1/0<br />

# 4-4/0<br />

Optional Al/Cu Pressure Terminals<br />

50<br />

100<br />

Breaker Rating,<br />

Amperes<br />

Al/Cu<br />

Al/Cu<br />

#14-#4<br />

# 4-4/0<br />

Conductor<br />

FB3022MRL<br />

FB3045MRL<br />

FB3110MRL<br />

2610D53G30<br />

FB3190MRL<br />

1268C14G06<br />

FB3270MRL<br />

1268C14G02<br />

FB3480MRL<br />

2610D53G31<br />

1268C14G04<br />

FB31550MRL<br />

FB31800MRL<br />

Package of<br />

Three Line<br />

Terminals➎<br />

Style Number<br />

624B100G14<br />

624B100G02<br />

624B100G17<br />

624B100G10<br />

624B100G17<br />

Screw<br />

Wire Clamp<br />

Style 624B100G14<br />

Assemble wire clamp to<br />

bottom of conductor as<br />

shown.<br />

Limiter<br />

For Thermal Magnetic Breakers➑<br />

15-70<br />

80-150<br />

For Magnetic Only Breakers➑<br />

3<br />

5<br />

10<br />

25<br />

30<br />

50<br />

70<br />

100<br />

150<br />

Catalog Number<br />

LFB3070R<br />

LFB3150R<br />

LFB3003MR<br />

LFB3005MR<br />

LFB3010MR<br />

LFB3025MR<br />

LFB3030MR<br />

LFB3050MR<br />

LFB3070MR<br />

LFB3100MR<br />

LFB3150MR<br />

FB3022SMRL<br />

FB3045SMRL<br />

FB3110SMRL<br />

4998D89G30<br />

FB3190SMRL<br />

. . . . . . . . . . . . .<br />

FB3270SMRL<br />

. . . . . . . . . . . . .<br />

FB3480SMRL<br />

2610D58G31<br />

81E4647<br />

FB31550SMRL<br />

FB31800SMRL<br />

➊ 2-pole magnetic only <strong>breakers</strong> supplied in 3-pole frame with current carrying parts omitted from center pole.<br />

➋ Magnetic only <strong>breakers</strong> for DC applications require special calibration. Order by description.<br />

➌ Magnetic only <strong>breakers</strong> include both line and load terminals.<br />

➍ Suffix “L” on catalog number indicates line and load terminals included. If factory installation is required, specify on order.<br />

➎ Style listed is for package of three terminals.<br />

➏ Not listed with Underwriters‘ Laboratories, Inc.<br />

➐ Cannot be used with plug-in adapters.<br />

➑ Ratings thru 70 amperes can be supplied with terminals for Cu cable only (#14-#2). Order by description.<br />

HFB3022ML<br />

HFB3045ML<br />

HFB3110ML<br />

4994D96G30<br />

HFB3190ML<br />

. . . . . . . . . .<br />

HFB3270ML<br />

. . . . . . . . . .<br />

HFB3480ML<br />

4994D96G31<br />

65E4667<br />

HFB31550ML<br />

HFB31800ML<br />

23<br />

Special Calibrations➏<br />

Special calibration price additions apply to<br />

ampere ratings not listed as standard or<br />

for ambients other than 40°C or 50°C. For<br />

frequencies other than 0-60 Hz AC, refer to<br />

Cutler-Hammer. See Application Data 29-<br />

160 for information regarding special conditions.<br />

Maximum calibration for 400 Hz is<br />

135 amperes.<br />

50°C Calibration➏<br />

Add suffix “V” to catalog number for complete<br />

breaker, listed above, when ordering<br />

<strong>breakers</strong> to be used in 50°C ambients.<br />

Ambient Compensating Breakers➏<br />

To order, add suffix letter “A” to standard<br />

thermal magnetic breaker catalog number.<br />

Available in all standard ratings of EB,<br />

EHB, FB and HFB <strong>breakers</strong> up to ratings of<br />

100 amperes. Factory adder 20%.<br />

Federal Specification Classifications<br />

EB, EHB, FB and HFB <strong>breakers</strong> meet<br />

requirements of Federal Specification<br />

W-C-375b as follows:<br />

EB: 1-pole, Class 11a; 2-, 3-poles, Classes<br />

10b, 11b, 12b<br />

EHB: 1-pole, Class 13a; 2-, 3-poles,<br />

Class 13b;<br />

FB: 2-, 3-poles, Class 18a;<br />

HFB: 1-pole, Class 13a; 2-, 3-poles,<br />

Class 22a<br />

For all 3-phase Delta, grounded B phase<br />

applications, contact your local Cutler-<br />

Hammer Field Sales Office.<br />