REPLACEMENT CAPABILITIES, Continued<br />
Special Breakers➊<br />
Type FB, Magnetic Only, Front Adjustable<br />
(Includes Line and Load Terminals)<br />
Continuous<br />
Ampere<br />
Rating<br />
3<br />
5<br />
10<br />
25<br />
25<br />
30<br />
30<br />
50<br />
50<br />
70<br />
100<br />
100<br />
150<br />
Accessories and Modifications<br />
Collar<br />
Conductor<br />
March 2001<br />
Magnetic<br />
Trip Range<br />
Amperes<br />
7 - 22<br />
15 - 45<br />
35 - 110<br />
32 - 80<br />
66 - 190<br />
50 - 150<br />
90 - 270<br />
66 - 190<br />
160 - 480<br />
100 - 270<br />
150 - 480<br />
450 - 1550<br />
575 - 1800<br />
Collar<br />
Nut<br />
Washer<br />
Conductor<br />
Screw<br />
MOLDED CASE CIRCUIT BREAKERS<br />
Replacement Circuit Breakers<br />
2-Pole➊➋,<br />
600 Volts AC 3-Pole, 600 Volts AC<br />
Standard MARK 75 Standard Saf-T-Vue MARK 75<br />
Catalog/Style Numbers<br />
FB2022MRL<br />
FB2045MRL<br />
FB2110MRL<br />
2610D53G12<br />
FB2190MRL<br />
1268C14G05<br />
FB2270MRL<br />
1268C14G01<br />
FB2480MRL<br />
2610D53G13<br />
1268C14G03<br />
FB21550MRL<br />
FB21800MRL<br />
Terminals<br />
Breakers include load terminals only➌➍.<br />
Terminals are Underwriters’ Laboratories,<br />
Inc. listed as suitable for wire type and<br />
size. When used with aluminum conductors,<br />
use joint compound. When line<br />
terminals are required, order by style<br />
number from table at no charge with the<br />
breaker.<br />
Style 624B100G02<br />
Insert collar enclosing<br />
conductor as shown.<br />
Locate nut on top of<br />
conductor and tighten<br />
securely with screw and<br />
washer. Caution: Collar<br />
must surround conductor.<br />
Style 624B100G10<br />
Assemble collar on<br />
top of conductor as<br />
shown. Tighten securely<br />
with screw and washer.<br />
LFB Current Limiter Attachment➐<br />
The LFB Current Limiter is an attachment<br />
that bolts to the load end of a standard FB<br />
thermal magnetic or magnetic only breaker,<br />
providing 200,000 Amperes Interrupting<br />
Capacity (AIC) at up to 600 volts AC.<br />
Limiters for thermal magnetic <strong>breakers</strong> are<br />
listed with Underwriters’ Laboratories, Inc.<br />
Current limiters must be applied as indicated<br />
in the table.<br />
Standard LFB terminals are suitable for<br />
Cu/AI cable. Ratings thru 70 amperes<br />
accept (1) #14-#2, and 100 and 150<br />
amperes accept (1) #1-4/0. ➑<br />
Max.<br />
Amperes<br />
Collar<br />
Washer<br />
Conductor<br />
Screw Extrusion<br />
HFB2022ML<br />
HFB2045ML<br />
HFB2110ML<br />
4994D96G12<br />
HFB2190ML<br />
. . . . . . . . . .<br />
HFB2270ML<br />
. . . . . . . . . .<br />
HFB2480ML<br />
4994D96G13<br />
. . . . . . . . . .<br />
HFB21550ML<br />
HFB21800ML<br />
Wire<br />
Type<br />
Style 624B100G17<br />
Clip<br />
Insert collar enclosing<br />
conductor and center on<br />
extrusion on collar. Install<br />
clip with legs on top of<br />
conductor and snap end<br />
around bottom of collar.<br />
Wire<br />
Range<br />
Standard Pressure Type Terminals<br />
20 (EB, EHB)<br />
100<br />
150<br />
Al/Cu<br />
Al/Cu<br />
Al/Cu<br />
#14-#10<br />
#14-1/0<br />
# 4-4/0<br />
Optional Al/Cu Pressure Terminals<br />
50<br />
100<br />
Breaker Rating,<br />
Amperes<br />
Al/Cu<br />
Al/Cu<br />
#14-#4<br />
# 4-4/0<br />
Conductor<br />
FB3022MRL<br />
FB3045MRL<br />
FB3110MRL<br />
2610D53G30<br />
FB3190MRL<br />
1268C14G06<br />
FB3270MRL<br />
1268C14G02<br />
FB3480MRL<br />
2610D53G31<br />
1268C14G04<br />
FB31550MRL<br />
FB31800MRL<br />
Package of<br />
Three Line<br />
Terminals➎<br />
Style Number<br />
624B100G14<br />
624B100G02<br />
624B100G17<br />
624B100G10<br />
624B100G17<br />
Screw<br />
Wire Clamp<br />
Style 624B100G14<br />
Assemble wire clamp to<br />
bottom of conductor as<br />
shown.<br />
Limiter<br />
For Thermal Magnetic Breakers➑<br />
15-70<br />
80-150<br />
For Magnetic Only Breakers➑<br />
3<br />
5<br />
10<br />
25<br />
30<br />
50<br />
70<br />
100<br />
150<br />
Catalog Number<br />
LFB3070R<br />
LFB3150R<br />
LFB3003MR<br />
LFB3005MR<br />
LFB3010MR<br />
LFB3025MR<br />
LFB3030MR<br />
LFB3050MR<br />
LFB3070MR<br />
LFB3100MR<br />
LFB3150MR<br />
FB3022SMRL<br />
FB3045SMRL<br />
FB3110SMRL<br />
4998D89G30<br />
FB3190SMRL<br />
. . . . . . . . . . . . .<br />
FB3270SMRL<br />
. . . . . . . . . . . . .<br />
FB3480SMRL<br />
2610D58G31<br />
81E4647<br />
FB31550SMRL<br />
FB31800SMRL<br />
➊ 2-pole magnetic only <strong>breakers</strong> supplied in 3-pole frame with current carrying parts omitted from center pole.<br />
➋ Magnetic only <strong>breakers</strong> for DC applications require special calibration. Order by description.<br />
➌ Magnetic only <strong>breakers</strong> include both line and load terminals.<br />
➍ Suffix “L” on catalog number indicates line and load terminals included. If factory installation is required, specify on order.<br />
➎ Style listed is for package of three terminals.<br />
➏ Not listed with Underwriters‘ Laboratories, Inc.<br />
➐ Cannot be used with plug-in adapters.<br />
➑ Ratings thru 70 amperes can be supplied with terminals for Cu cable only (#14-#2). Order by description.<br />
HFB3022ML<br />
HFB3045ML<br />
HFB3110ML<br />
4994D96G30<br />
HFB3190ML<br />
. . . . . . . . . .<br />
HFB3270ML<br />
. . . . . . . . . .<br />
HFB3480ML<br />
4994D96G31<br />
65E4667<br />
HFB31550ML<br />
HFB31800ML<br />
23<br />
Special Calibrations➏<br />
Special calibration price additions apply to<br />
ampere ratings not listed as standard or<br />
for ambients other than 40°C or 50°C. For<br />
frequencies other than 0-60 Hz AC, refer to<br />
Cutler-Hammer. See Application Data 29-<br />
160 for information regarding special conditions.<br />
Maximum calibration for 400 Hz is<br />
135 amperes.<br />
50°C Calibration➏<br />
Add suffix “V” to catalog number for complete<br />
breaker, listed above, when ordering<br />
<strong>breakers</strong> to be used in 50°C ambients.<br />
Ambient Compensating Breakers➏<br />
To order, add suffix letter “A” to standard<br />
thermal magnetic breaker catalog number.<br />
Available in all standard ratings of EB,<br />
EHB, FB and HFB <strong>breakers</strong> up to ratings of<br />
100 amperes. Factory adder 20%.<br />
Federal Specification Classifications<br />
EB, EHB, FB and HFB <strong>breakers</strong> meet<br />
requirements of Federal Specification<br />
W-C-375b as follows:<br />
EB: 1-pole, Class 11a; 2-, 3-poles, Classes<br />
10b, 11b, 12b<br />
EHB: 1-pole, Class 13a; 2-, 3-poles,<br />
Class 13b;<br />
FB: 2-, 3-poles, Class 18a;<br />
HFB: 1-pole, Class 13a; 2-, 3-poles,<br />
Class 22a<br />
For all 3-phase Delta, grounded B phase<br />
applications, contact your local Cutler-<br />
Hammer Field Sales Office.<br />
A