206<br />

STARTERS (MEDIUM VOLTAGE)<br />

SJ Vacuum AMPGARD Assemblies, Retrofit Kits<br />

and Renewal Parts<br />

PRODUCT DESCRIPTION<br />

Originally a Westinghouse Product<br />

The SJ Vacuum Contactor was designed<br />

and engineered specifically for use in<br />

AMPGARD starters. The contactor is a<br />

low-chop design that permits application<br />

matching of the starter to the motor for<br />

2200V - 7200V and ratings of 400A and<br />

800A. The 400A contactor is available in<br />

both slide-out and roll-out configurations.<br />

The 800A contactor is available in the rollout<br />

design only. The SJ AMPGARD is a<br />

horsepower specific starter design that<br />

uses the component-to-component <strong>circuit</strong>ry<br />

concept. The full-voltage 400A rating<br />

in a NEMA 1 enclosure is 36 inches<br />

wide x 30 inches deep x 90 inches high.<br />

These 400A starters are mounted one or<br />

two high per structure. The 800A rating in<br />

an enclosure is 40 inches wide x 30 inches<br />

REPLACEMENT CAPABILITIES<br />

Renewal and Replacement Parts for<br />

SJ Design Starters<br />

Refer to RPD 8855V or RP.48J.01.T.E for<br />

identifying the parts needed. Refer to Price<br />

List/Style Number Index 8855 for prices by<br />

style number and old style number-to-new<br />

style number cross-reference information.<br />

deep x 90 inches high in a one-high<br />

construction for a full voltage starter.<br />

Ratings (max.)<br />

400A, 800A<br />

3000 HP @ 2500V; 5500 HP @ 5000V;<br />

8000 HP @ 7200V<br />

Chronology<br />

The SJ vacuum design AMPGARD starter<br />

was introduced in 1982 with the 400A<br />

rating. The 800A rating followed in 1987.<br />

With the introduction of the vacuum<br />

contactor, the air break starter has been<br />

gradually phased out and is rarely specified<br />

in an assembly. The starters are built<br />

in Asheville, NC.<br />

Synchronous Control Retrofit Using<br />

Mark V Solid-State Control<br />

Replace existing relay type synchronous<br />

control with state-of-the-art solid-state<br />

Mark V control. Refer to pages 186-189,<br />

192 of this publication for synchronous<br />

motor field control panels.<br />

TECHNOLOGY UPGRADES<br />

Vacuum Starter Retrofits IQ Retrofit Kits<br />

400A Vacuum Starter Retrofit Kit<br />

IQ 1000 II and Data Plus II Retrofit Kit<br />

Complete full-voltage, non-reversing, This kit includes parts necessary to retrofit<br />

induction, vacuum AMPGARD motor starter, IQ products into AMPGARD starters very<br />

400A, 7200V max., for mounting in exist- easily. The IQ devices are included and are<br />

ing 36-inch wide enclosure. Includes main pre-wired to terminal blocks on the<br />

contactor, isolation switch three power drawout panel.<br />

fuses, IQ 1000 II motor protection without<br />

RTD module, three current transformers,<br />

vertical bus, high- and low-voltage doors,<br />

and welded cell assembly for mounting in<br />

existing 36-inch wide customer enclosure.<br />

Refer to RPD 8855C for more details.<br />

Included: Typical starter schematics, 400A<br />

Low-voltage door with three<br />

device panels<br />

Works-in-a-drawer panel with<br />

terminal blocks<br />

IQ 1000 II (without RTD)<br />

Style No. 2147A95G01 (Slideout)<br />

IQ Data Plus II (with MWH<br />

Style No. 2147A95G02 (Rollout)<br />

counter)<br />

Style No. 2147A95G37<br />

Low Resolution Photo<br />

Current Transformer Shorting<br />

Terminal Blocks (When Specified)<br />

Routing of Control Wire in Wire Channel<br />

Interposing Control Relay<br />

DIN – Rail Mounted<br />

Wiring is Protected Between Low Voltage<br />

Panel and Hinged Low Voltage Door<br />

Low Voltage Panel Completely Extended<br />

IQ 1000 II/Data Plus II Retrofit<br />

Add-on Vacuum Starter Structures<br />

New add-on vacuum structures as an<br />

extension to the SJ type structure may be<br />

connected directly to the main bus without<br />

a transition section. Contact your local<br />

Cutler-Hammer Field Sales Office.<br />

Replacement Vacuum Contactors<br />

New replacement vacuum break contactors<br />

are available for all SJ model ratings.<br />

IQ Surface Mounted Enclosure<br />

For mounting IQ family products. Includes<br />

drilling for one IQ device and three 30mm<br />

devices. Supplied with or without IQ and<br />

PB devices. Refer to RPD 8855C for more<br />

details.<br />

IQ Floor Mounted Enclosure<br />

For mounting IQ family products. Includes<br />

standard AMPGARD structure construction<br />

to be used as a line-up extension. Each<br />

12-inch wide x 90-inch high x 30-inch deep<br />

section comes with two doors, each with a<br />

works-in-a-drawer drawout panel. Each<br />

door has three standard IQ cutouts with<br />

device panels. Supplied with or without IQ<br />

and PB devices. Refer to RPD 8855C for<br />

more details.<br />

Rear of 1/4 Turn Fastener<br />

Predrilled Holes for<br />

Additional Control Devices<br />

IQ-1000 Rear View<br />

Indicating Lights and<br />

Pushbuttons Rear View<br />

Blank Device Panel<br />

NOTE: Low Voltage Door is<br />

Hinged to Slide Out Control Panel<br />

March 2001