292<br />

Current System Selection Guide<br />

Literature Number Description<br />

SA-151<br />

SA-231<br />

SA-234<br />

SA-106<br />

SA-247<br />

EXCITATION CONTROL EQUIPMENT<br />

Voltage Regulators and Static Excitation Systems<br />

GENERAL INFORMATION<br />

Application selection for various field current requirements. Consult the factory for quotation.<br />

Equipment<br />

Type<br />

MGR<br />

PRX-302<br />

PRX-302➊<br />

PRX-302X5➊<br />

PRX-400B<br />

WTA-300B<br />

Brushless<br />

PRX-300<br />

WTA-300B<br />

WDR-2000<br />

Portable<br />

excitation<br />

systems<br />

REPLACEMENT CAPABILITIES<br />

Renewal Parts<br />

Application Features<br />

AVR SEVR General Specific Excitation<br />

● ●<br />

●<br />

●<br />

●<br />

FURTHER INFORMATION<br />

●<br />

●<br />

● ●<br />

● ●<br />

• New generators<br />

• Existing generators<br />

• New installations<br />

- Combustion turbines<br />

- Steam turbines<br />

- Prime movers (i.e., diesel engines)<br />

Renewal Parts<br />

Cutler-Hammer offers a complete line of<br />

spare parts for current systems as well<br />

as parts for some systems not currently<br />

manufactured. The table to the right lists<br />

systems that have spare parts available.<br />

For those systems that do not have spare<br />

parts available, the recommended<br />

replacement system is listed.<br />

TRA Voltage Regulator<br />

Sales Aid for MGR Excitation Systems<br />

Sales Aid for WDR Digital Regulator<br />

Sales Aid for WDRT Digital Test Kit<br />

Sales Aid for Potentiometer Replacement<br />

Sales Aid for Voltage Regulation Is Our Business<br />

Supplies excitation to single field exciters or<br />

generator fields up to 600 amperes<br />

Service Information<br />

For service information contact your local Cutler-Hammer Field Sales Office or<br />

Westinghouse Engineering Services.<br />

Supplies excitation for brushless exciters for generators<br />

up to 100 MVA<br />

Renewal Parts Available<br />

Product Parts Not<br />

Available<br />

BJ-30 ●<br />

WMA ●<br />

WMA BR➋<br />

●<br />

WR-20<br />

Turbograph<br />

●<br />

SRA/SRD<br />

TRA/TRD/<br />

TRX<br />

XASV<br />

XMC<br />

WTA<br />

WTA-300<br />

SEVR<br />

PRX-300<br />

PRX-302<br />

PRX-400<br />

MGR<br />

WDR-2000<br />

• Multi-function logic modularity<br />

• Front access only cubicle<br />

• Fixed power rectifiers<br />

• Modular logic<br />

• Provisions for redundancy<br />

• Front access only design<br />

Retrofit applications Retrofit for WMA and WR-20 regulators • Modular logic<br />

• Provisions for redundancy<br />

• New steam turbine<br />

installations > 100 MVA<br />

• Retrofit applications<br />

• New generators<br />

• Existing generators<br />

• New generators<br />

• Existing generators<br />

• New generation<br />

• Existing generators<br />

• Portable standby<br />

excitation systems<br />

AVR = Automatic voltage regulator (supplies excitation to exciter field)<br />

SEVR = Static exciter voltage regulator (supplies excitation to generator field)<br />

Supplies excitation for generators 100 MVA and up<br />

Primary retrofit for WMA brushless systems<br />

• Modular logic<br />

• Provisions for redundancy<br />

• Draw-out power rectifiers<br />

• Draw-out AC disconnect<br />

Supplies excitation for generator fields up to 400 amperes • Modular logic<br />

• Provisions for redundancy<br />

• Fixed power rectifiers<br />

Supplies excitation for generator fields 500 amperes and up • Modular logic<br />

• Provisions for redundancy<br />

• Draw-out power rectifiers<br />

• Draw-out AC disconnect<br />

Supplies excitation to exciter field or directly to the<br />

generator field<br />

• Digital Logic<br />

• Provisions for redundancy<br />

• Draw-out power rectifiers<br />

• Draw-out AC disconnect<br />

Supplies excitation for systems 6000 amperes and up • Supplied in outdoor enclosure<br />

• Multi-generator design<br />

• Utilizes WTA-300B system<br />

• Trailer or skid mounted<br />

●<br />

Parts<br />

Available<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

Current<br />

Replacement<br />

MGR<br />

PRX-400<br />

WTA-300<br />

PRX-400<br />

TRA-TRD<br />

XMC<br />

PRICING INFORMATION<br />

WTA-300B<br />

Call the Cutler-Hammer Asheville Plant<br />

for pricing.<br />

➊ PRX302 = 420 Hz PMG (permanent magnet<br />

generator) supply, PRX302X = 60 Hz XMFR<br />

supply, PRX302X5 = 50 Hz XMFR supply.<br />

➋ WMA brushless.<br />

March 2001