GENERAL INFORMATION<br />

Modifications<br />

Modification<br />

Enclosures<br />

March 2001<br />

List Price<br />

Addition<br />

a. NEMA 1, with gasketed door ............................................................................... $ 340<br />

b. NEMA 3, weather-resisting..................................................................................... 2740<br />

c. NEMA 12, dust-tight ................................................................................................ 2500<br />

Omit Enclosure (Floor Mounted) ➊ ................................................................... Deduct 375<br />

Space Heater .......................................................................................................................... 140<br />

Thermostat for Space Heater................................................................................................ 100<br />

Voltmeter DC — Panel Type ................................................................................................. 480<br />

Voltmeter DC — Switchboard Type ..................................................................................... 680<br />

Ammeter DC — Switchboard Type (In lieu of Panel Type) ................................................ 200<br />

DC voltage failure protection — Shuts down motor if field voltage<br />

is lost while motor is running............................................................................................ 740<br />

Adjustable potential voltage static exciter<br />

Contact your local Cutler-Hammer Field Sales Office.<br />

For additional modifications, refer to PL 8810.<br />

SYNCHRONOUS MOTOR CONTROL<br />

Brush Type Relay Slipsyn<br />

Class 14-100 Field Application Panel<br />

REPLACEMENT CAPABILITIES — TYPICAL RELAY COMPONENTS<br />

ASR Synchronous Relay<br />

Low Resolution Photo<br />

PO Pull-Out Relay<br />

DP Damper Protective Relay<br />

Typical Relay Components used in Relay Slipsyn — Refer to RPD 8855S for renewal parts for<br />

synchronous control<br />

➊ If enclosure is omitted, starting and discharge resistor and DC ammeter will be supplied loose and unmounted.<br />

List Price<br />

Relay Slipsyn Field Panel With and<br />

Without Static Exciter<br />

NEMA 1 Enclosure<br />

Max.<br />

Field<br />

Amps<br />

DC<br />

45<br />

90<br />

135<br />

160<br />

200<br />

270<br />

Field<br />

Panel<br />

Only<br />

Without<br />

Exciter<br />

$ 9454<br />

10515<br />

11575<br />

12065<br />

13285<br />

14955<br />

185<br />

With Constant Potential Exciter<br />

Primary Volts<br />

Low Voltage Medium Voltage<br />

230/460 3PH, 2300/4160, 3PH,<br />

60 Hz<br />

60 Hz<br />

DC Field Volts DC Field Volts<br />

125 250 125 250<br />

$17725<br />

18825<br />

19970<br />

21030<br />

23150<br />

26410<br />

$19480<br />

20700<br />

22005<br />

23100<br />

25430<br />

29015<br />

$21350<br />

22740<br />

24045<br />

25430<br />

28040<br />

31900<br />

DIMENSIONS IN INCHES<br />

Approximate only<br />

Field Panel Only — Open Panel<br />

CUSTOMER REQUIRED<br />

INFORMATION<br />

PRICING INFORMATION<br />

1. Enter order on AMP<br />

2. Discount Symbol: SYNCH<br />

$24530<br />

26080<br />

27630<br />

29260<br />

32200<br />

36650<br />

135 Amps. Max. Over 135 Amps.<br />

Height Width Depth<br />

24 24 12 Contact your local<br />

Cutler-Hammer<br />

Field Sales Office<br />

Field Panel with Static Exciter 13 kW Max.<br />

Open Cell Floor Mounted — NEMA 1<br />

Height Width Depth Height Width Depth<br />

45 36 30 90 36 30<br />

1. Complete motor data: HP, volts,<br />

amperes, rpm, phase, power factor,<br />

Hz, locked rotor amperes, full load DC<br />

amperes, excitation volts, induced<br />

field amperes at zero speed, induced<br />

field amperes at 95% and 0% speed,<br />

recommended discharge resistor ohms,<br />

maximum locked time at zero speed.<br />

2. Excitation control.<br />

For exciter field rheostat or motor field<br />

resistor to adjust motor excitation,<br />

refer to Cutler-Hammer.<br />

3. Application data (including any<br />

unusual service conditions) and 100%<br />

synchronous motor data MUST<br />

accompany each other.<br />

M

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!