142<br />
COMMUNICATIONS SYSTEMS (IMPACC)<br />
For New and Existing Electrical Equipment<br />
GENERAL INFORMATION, Continued<br />
Electronic Device IMPACC System Selection Chart<br />
Device Name Descrip- Assembly Applications<br />
tive<br />
Bulletin<br />
Medium Voltage (Above 600V) Low Voltage (600V and Below)<br />
FUNCTION<br />
METERING AND<br />
MONITORING<br />
OVERCURRENT<br />
PROTECTION<br />
MOTOR<br />
PROTECTION<br />
OTHER<br />
DEVICES<br />
LOCAL DISPLAY UNITS<br />
IMPACC COMMUNICATIONS<br />
Substation<br />
Breakers<br />
Metal-Clad<br />
Switchgear<br />
(VacClad)<br />
Metal-Enclosed<br />
Switchgear<br />
(WVB)<br />
Fused Metal-<br />
Enclosed Switchgear<br />
(WLI)<br />
Motor Starter<br />
(Ampgard)<br />
Substation/Unit<br />
Sub Transformer<br />
Metal-Enclosed<br />
Switchgear<br />
(Type DS)<br />
Low-Voltage<br />
Switchboard<br />
(Pow-R-Line C)<br />
Low-Voltage<br />
Panelboard<br />
(Pow-R-Line C)<br />
Motor Control<br />
(Series 2100)<br />
Adjustable<br />
Frequency<br />
Drives<br />
Busway Plugs<br />
IQ Analyzer 8179 RI/RF RI/OF RI/OF RI/OF RI RI RI O<br />
IQ DP-4000 8170 RF RF RF RIF OI OI OI O<br />
IQ Data Plus II (< 14.4 kV) 8176 RF RF RF RF OI OI OI O<br />
IQ Data Plus II HV (> 14.4 kV) 8176 RF RF RF RF<br />
IQ Data 8171 OI OI OI<br />
IQ Generator 8172 OI<br />
IQ Energy Sentinel 1 8178 RF RF RF RF<br />
Digitrip MV 33-750 R R R<br />
Digitrip RMS 810 R RI<br />
Digitrip RMS 910 O OI<br />
Digitrip OPTIM 750 O R R OF O<br />
Digitrip OPTIM 1050 O O O OF O<br />
IQ 1000 II 8173 RF RF OF<br />
IQ 500 8177 OF OF<br />
ADVANTAGE Starter RF<br />
AFD Device Panel R<br />
IQ Transfer O O R<br />
Addressable Relay II O O O R R O O O O<br />
RTD Module R R O<br />
Central Energy Display II - CED II<br />
(IQ Energy Sentinel)<br />
Central Monitoring Unit - CMU<br />
(ADVANTAGE Starter)<br />
Assemblies Electronic Monitor - AEM II<br />
(Digitrip RMS)<br />
OPTIM Breaker Interface Module - BIM<br />
(Digitrip OPTIM and Digitrip RMS 810<br />
and 910)<br />
IMPACC SYSTEMS<br />
SOFTWARE<br />
HARDWARE<br />
8178 R R R<br />
8226 R<br />
8175 R R<br />
R R R<br />
Standard Software Presents System Data in Spreadsheet Format<br />
Graphic Software Depicts System and Equipment Information Graphically<br />
Power Distribution System<br />
Power Analysis Software<br />
Utilizes Device Transmitted Data in Application Specific Software Packages<br />
Network Diagnostic System Start-up and Troubleshooting Information<br />
PONI Mounted on Rear of Applicable IQ Products<br />
CONI IBM Compatible Computer Bus Card<br />
MINT Device Normally Located at PC or Interface Point<br />
PLC Interface Card Mounted in Cutler-Hammer 500 Series PLC<br />
Mod Bus Gateway Device Normally Located at Interface Point<br />
Ethernet Interface Bridge Device Normally Located at Interface Point<br />
IQ DC Power Supply Used for IQ Devices That Do Not Directly Accept DC Power<br />
Legend: R = Recommended Application<br />
O = Optional Application<br />
I = Incoming Main Line<br />
F = Feeder<br />
Refer to Page 130 of this document.<br />
Automatic<br />
Transfer<br />
Switches<br />
March 2001