06.03.2013 Views

molded case circuit breakers - Eaton Canada

molded case circuit breakers - Eaton Canada

molded case circuit breakers - Eaton Canada

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

142<br />

COMMUNICATIONS SYSTEMS (IMPACC)<br />

For New and Existing Electrical Equipment<br />

GENERAL INFORMATION, Continued<br />

Electronic Device IMPACC System Selection Chart<br />

Device Name Descrip- Assembly Applications<br />

tive<br />

Bulletin<br />

Medium Voltage (Above 600V) Low Voltage (600V and Below)<br />

FUNCTION<br />

METERING AND<br />

MONITORING<br />

OVERCURRENT<br />

PROTECTION<br />

MOTOR<br />

PROTECTION<br />

OTHER<br />

DEVICES<br />

LOCAL DISPLAY UNITS<br />

IMPACC COMMUNICATIONS<br />

Substation<br />

Breakers<br />

Metal-Clad<br />

Switchgear<br />

(VacClad)<br />

Metal-Enclosed<br />

Switchgear<br />

(WVB)<br />

Fused Metal-<br />

Enclosed Switchgear<br />

(WLI)<br />

Motor Starter<br />

(Ampgard)<br />

Substation/Unit<br />

Sub Transformer<br />

Metal-Enclosed<br />

Switchgear<br />

(Type DS)<br />

Low-Voltage<br />

Switchboard<br />

(Pow-R-Line C)<br />

Low-Voltage<br />

Panelboard<br />

(Pow-R-Line C)<br />

Motor Control<br />

(Series 2100)<br />

Adjustable<br />

Frequency<br />

Drives<br />

Busway Plugs<br />

IQ Analyzer 8179 RI/RF RI/OF RI/OF RI/OF RI RI RI O<br />

IQ DP-4000 8170 RF RF RF RIF OI OI OI O<br />

IQ Data Plus II (< 14.4 kV) 8176 RF RF RF RF OI OI OI O<br />

IQ Data Plus II HV (> 14.4 kV) 8176 RF RF RF RF<br />

IQ Data 8171 OI OI OI<br />

IQ Generator 8172 OI<br />

IQ Energy Sentinel 1 8178 RF RF RF RF<br />

Digitrip MV 33-750 R R R<br />

Digitrip RMS 810 R RI<br />

Digitrip RMS 910 O OI<br />

Digitrip OPTIM 750 O R R OF O<br />

Digitrip OPTIM 1050 O O O OF O<br />

IQ 1000 II 8173 RF RF OF<br />

IQ 500 8177 OF OF<br />

ADVANTAGE Starter RF<br />

AFD Device Panel R<br />

IQ Transfer O O R<br />

Addressable Relay II O O O R R O O O O<br />

RTD Module R R O<br />

Central Energy Display II - CED II<br />

(IQ Energy Sentinel)<br />

Central Monitoring Unit - CMU<br />

(ADVANTAGE Starter)<br />

Assemblies Electronic Monitor - AEM II<br />

(Digitrip RMS)<br />

OPTIM Breaker Interface Module - BIM<br />

(Digitrip OPTIM and Digitrip RMS 810<br />

and 910)<br />

IMPACC SYSTEMS<br />

SOFTWARE<br />

HARDWARE<br />

8178 R R R<br />

8226 R<br />

8175 R R<br />

R R R<br />

Standard Software Presents System Data in Spreadsheet Format<br />

Graphic Software Depicts System and Equipment Information Graphically<br />

Power Distribution System<br />

Power Analysis Software<br />

Utilizes Device Transmitted Data in Application Specific Software Packages<br />

Network Diagnostic System Start-up and Troubleshooting Information<br />

PONI Mounted on Rear of Applicable IQ Products<br />

CONI IBM Compatible Computer Bus Card<br />

MINT Device Normally Located at PC or Interface Point<br />

PLC Interface Card Mounted in Cutler-Hammer 500 Series PLC<br />

Mod Bus Gateway Device Normally Located at Interface Point<br />

Ethernet Interface Bridge Device Normally Located at Interface Point<br />

IQ DC Power Supply Used for IQ Devices That Do Not Directly Accept DC Power<br />

Legend: R = Recommended Application<br />

O = Optional Application<br />

I = Incoming Main Line<br />

F = Feeder<br />

Refer to Page 130 of this document.<br />

Automatic<br />

Transfer<br />

Switches<br />

March 2001