Switchgear Kits and Renewal Parts<br />

March 2001<br />

SWITCHGEAR (LOW VOLTAGE)<br />

DS Assemblies, Power Circuit Breakers<br />

and Renewal Parts<br />

REPLACEMENT CAPABILITIES, Continued<br />

Neutral Sensors<br />

The sensor kit includes a fourth current<br />

sensor and mounting hardware for four<br />

wire ground fault protection. Additional<br />

wiring needs to be done to the DS <strong>circuit</strong><br />

breaker. (If there is no ground fault protection<br />

on the existing DS <strong>circuit</strong> breaker, the<br />

trip unit also needs to be changed).<br />

Kit contains one neutral sensor, mounting<br />

plate, and hardware.<br />

Sensor Rating<br />

Amperes<br />

50<br />

100<br />

150<br />

200<br />

300<br />

400<br />

600<br />

800<br />

1200<br />

1600<br />

2000<br />

CTD-2 CTD-10<br />

Sensor Style<br />

Number<br />

3A73101G01<br />

3A73101G02<br />

3A73101G03<br />

3A73101G04<br />

3A73101G05<br />

3A73101G06<br />

3A73101G07<br />

3A73101G08<br />

3A73101G09<br />

3A73101G10<br />

3A73101G11<br />

Capacitor Trip Device<br />

120 Vac<br />

DS Switchgear<br />

Style Number CTD-1 (330 Microfarad)<br />

Style Number CTD-2 (1500 Microfarad)<br />

DSII<br />

Switchgear<br />

Style Number CTD-10 (330 Microfarad)<br />

Order Entry Point – LVP<br />

DS Breaker Cell Switch<br />

3-NO, 3-NC<br />

Style Number 2A89010G01<br />

6-NO, 6-NC<br />

Style Number 2A89010G02<br />

Three-Phase Current Transformer<br />

Below is a three-phase current transformer<br />

that takes the guess work out of wiring<br />

along with a new glass polyester barrier<br />

and required hardware. This can be used<br />

instead of the individual current transformers<br />

for metering and instrumentation<br />

only. Only applicable for DS206, DS206H,<br />

DS206S, DSL206, DS416, DS416S, DS416H,<br />

DSL416 and DS420 <strong>circuit</strong> <strong>breakers</strong>.<br />

Ratio Style Number<br />

250:5<br />

300:5<br />

400:5<br />

500:5<br />

600:5<br />

750:5<br />

800:5<br />

1000:5<br />

1200:5<br />

1500:5<br />

1600:5<br />

2000:5<br />

3A73102G01<br />

3A73102G02<br />

3A73102G03<br />

3A73102G04<br />

3A73102G05<br />

3A73102G06<br />

3A73102G07<br />

3A73102G08<br />

3A73102G09<br />

3A73102G10<br />

3A73102G11<br />

3A73102G12<br />

Key Interlock Provisions<br />

The key interlock provision kit includes all<br />

of the necessary hardware to complete a<br />

provision for all DS <strong>circuit</strong> <strong>breakers</strong>. The<br />

kit includes a new divider panel and blank<br />

plates to accept a key interlock. (two<br />

cylinders max.)<br />

Key Interlock Provision for DS-206,<br />

DS-206S, DS-206H, DSL-206, DS-416,<br />

DS-416S, DS-416H, DSL-416, and DS-420<br />

Style Number 3A73116G01<br />

Key Interlock Provision for DS-632 and DSL-632.<br />

Style Number 3A73116G02<br />

Key Interlock Provision for DS-840 and DSL-840<br />

Style Number 3A73116G03<br />

241<br />

Current Transformers<br />

The current transformers shown below<br />

are for metering and instrumentation<br />

only. Do not use these current transformers<br />

for relaying. Kit contains three current<br />

transformers and required hardware.<br />

Current Transformer Type<br />

DSM-16 DSM-32 DSM-40<br />

DS206, S, H<br />

DS416, S, H<br />

DS420<br />

DSL206<br />

DSL416<br />

DS632<br />

DSL632<br />

DS840<br />

DSL840<br />

Type Ratio Style Number<br />

DSM-16<br />

DSM-16<br />

DSM-16<br />

DSM-16<br />

DSM-16<br />

DSM-16<br />

DSM-16<br />

DSM-16<br />

DSM-16<br />

DSM-16<br />

DSM-16<br />

DSM-16<br />

DSM-16<br />

DSM-16<br />

DSM-16<br />

DSM-16<br />

DSM-32<br />

DSM-32<br />

DSM-32<br />

DSM-32<br />

DSM-32<br />

DSM-40<br />

DSM-40<br />

DSM-40<br />

100:5<br />

150:5<br />

200:5<br />

250:5<br />

300:5<br />

400:5<br />

500:5<br />

600:5<br />

800:5<br />

1000:5<br />

1200:5<br />

1500:5<br />

1600:5<br />

2000:5<br />

2500:5<br />

3000:5<br />

2400:5<br />

2500:5<br />

3000:5<br />

3200:5<br />

4000:5<br />

4000:5<br />

5000:5<br />

6000:5<br />

Secondary Contact (Eight Point)<br />

Style Number 590C808G01<br />

3A73103G01<br />

3A73103G02<br />

3A73103G03<br />

3A73103G04<br />

3A73103G05<br />

3A73103G06<br />

3A73103G07<br />

3A73103G08<br />

3A73103G09<br />

3A73103G10<br />

3A73103G11<br />

3A73103G12<br />

3A73103G13<br />

3A73103G14<br />

3A73103G15<br />

3A73103G16<br />

3A73103G17<br />

3A73103G18<br />

3A73103G19<br />

3A73103G20<br />

3A73103G21<br />

3A73103G22<br />

3A73103G23<br />

3A73103G24<br />

R