218<br />

Replacement Parts<br />

MOTOR CONTROL CENTERS<br />

REPLACEMENT CAPABILITIES<br />

In addition to replacement units, a large number of replacement parts are available for each vintage.<br />

Examples:<br />

F2100 Horizontal Wireway Door<br />

F10 Handle Mechanism<br />

MCC Replacement Circuit Breakers<br />

Cutler-Hammer Motor Control Center<br />

Replacement Circuit Breakers are newly<br />

manufactured and tested to the latest<br />

applicable standards at the Cutler-Hammer<br />

<strong>molded</strong> <strong>case</strong> <strong>circuit</strong> breaker plant in Beaver,<br />

PA. This plant has a long and well<br />

recognized tradition of product safety,<br />

integrity and quality.<br />

All Motor Control Center Replacement<br />

Circuit Breakers are easily identified by the<br />

prefix ”RMC“ added to the out-of-production<br />

type <strong>circuit</strong> breaker catalog number<br />

they replace.<br />

9800 Unit Mounting Hardware Kit<br />

Freedom Unitrol Terminal Block Mounting Kit<br />

For information on these and additional parts, refer to RPD 8991.<br />

For parts not listed or shown in RPD 8991, contact your local Cutler-Hammer Field Sales Office.<br />

Out-of-Production<br />

Circuit Breaker<br />

F<br />

HF<br />

FA<br />

HFA<br />

MCC Replacement<br />

Circuit Breaker<br />

RMCF<br />

RMCHF<br />

RMCFA<br />

RMCHFA<br />

Type W Horizontal Bus Bar<br />

Series 2100 Bus Splice Kit<br />

Motor Control Center Replacement Breakers<br />

do not have the same physical dimensions<br />

or mounting holes as the <strong>breakers</strong><br />

they replace. Types RMCFA and RMCHFA<br />

are 6 inches in length and the <strong>breakers</strong> they<br />

replace, FA and HFA, are 6-1⁄ 2 inches in<br />

length. Types RMCF and RMCHF are<br />

6 inches in length and the <strong>breakers</strong> they<br />

replace, F and HF, are 9-1⁄8 inches in length.<br />

A mounting plate is provided with each<br />

breaker to resolve these differences, and<br />

must be installed to ensure a proper fit.<br />