24<br />

Continuous<br />

Ampere<br />

Rating<br />

at 40°C<br />

Continuous<br />

Ampere<br />

Rating<br />

at 40°C<br />

250<br />

250<br />

250<br />

250<br />

250<br />

250<br />

Magnetic Trip Setting,<br />

Amperes (Set on High<br />

Side, Adjustable to<br />

Lower Limits)<br />

Low High<br />

2-Poles, 600 Volts AC, 250 Volts DC➌<br />

70<br />

90<br />

100<br />

125<br />

150<br />

175<br />

200<br />

225<br />

250<br />

350<br />

450<br />

500<br />

625<br />

750<br />

875<br />

1000<br />

1125<br />

1250<br />

3-Poles, 600 Volts AC Only<br />

70<br />

90<br />

100<br />

125<br />

150<br />

175<br />

200<br />

225<br />

250<br />

MOLDED CASE CIRCUIT BREAKERS<br />

Replacement Circuit Breakers<br />

REPLACEMENT CAPABILITIES, Continued<br />

Type JB 90-250 Amperes, 600 Volts AC, 250 Volts DC, 2- and 3 -Poles, Fixed Trip, Thermal Magnetic, Saf-T-Vue<br />

350<br />

450<br />

500<br />

625<br />

750<br />

875<br />

1000<br />

1125<br />

1250<br />

Magnetic Trip Setting,<br />

Amperes (Set on High<br />

Side, Adjustable to<br />

Lower Limits)<br />

Low High<br />

350<br />

625<br />

750<br />

875<br />

1125<br />

1250<br />

700<br />

900<br />

1000<br />

1250<br />

1500<br />

1750<br />

2000<br />

2250<br />

2500<br />

700<br />

900<br />

1000<br />

1250<br />

1500<br />

1750<br />

2000<br />

2250<br />

2500<br />

700<br />

1250<br />

1500<br />

1750<br />

2250<br />

2500<br />

Complete Breaker<br />

Includes Pressure Type<br />

Aluminum Terminals➊<br />

Standard Saf-T-Vue➋<br />

Catalog Numbers<br />

JB2070<br />

JB2090<br />

JB2100<br />

JB2125<br />

JB2150<br />

JB2175<br />

JB2200<br />

JB2225<br />

JB2250<br />

Breaker Only, No Terminals➍<br />

2-Poles➌<br />

Standard Saf-T-Vue<br />

Catalog Numbers<br />

JB2700MW<br />

JB21250MW<br />

JB21500MW<br />

JB21750MW<br />

JB22250MW<br />

JB22500MW<br />

JB2070S<br />

JB2090S<br />

JB2100S<br />

JB2125S<br />

JB2150S<br />

JB2175S<br />

JB2200S<br />

JB2225S<br />

JB2250S<br />

JB2700SMW<br />

JB21250SMW<br />

JB21500SMW<br />

JB21750SMW<br />

JB22250SMW<br />

JB22500SMW<br />

Breaker Without Terminals<br />

Standard Saf-T-Vue➋<br />

JB2070W<br />

JB2090W<br />

JB2100W<br />

JB2125W<br />

JB2150W<br />

JB2175W<br />

JB2200W<br />

JB2225W<br />

JB2250W<br />

3-Poles<br />

Standard Saf-T-Vue<br />

JB3700MW<br />

JB31250MW<br />

JB31500MW<br />

JB31750MW<br />

JB32250MW<br />

JB32500MW<br />

JB2070SW<br />

JB2090SW<br />

JB2100SW<br />

JB2125SW<br />

JB2150SW<br />

JB2175SW<br />

JB2200SW<br />

JB2225SW<br />

JB2250SW<br />

Approx. ship. wt. 12 lbs. Approx. ship. wt. 12 lbs.<br />

JB3070<br />

JB3090<br />

JB3100<br />

JB3125<br />

JB3150<br />

JB3175<br />

JB3200<br />

JB3225<br />

JB3250<br />

Magnetic Only Breakers, Front Adjustable ➋<br />

Accessories and Modifications<br />

Special Calibrations➋<br />

Special calibration price additions apply to<br />

ampere ratings not listed as standard or<br />

for ambients other than 40°C or 50°C. For<br />

frequencies other than 0-60 Hz AC, refer to<br />

Cutler-Hammer.<br />

50°C Calibration➋<br />

Add suffix “V” to catalog number for complete<br />

breaker when ordering <strong>breakers</strong> to<br />

be used in 50°C ambients. Same price as<br />

standard 40°C <strong>breakers</strong>.<br />

For CSA, see page 41.<br />

Type JB <strong>breakers</strong> meet requirements of<br />

Class 19a <strong>circuit</strong> <strong>breakers</strong> as defined by<br />

Federal Specification W-C-375b.<br />

JB3070S<br />

JB3090S<br />

JB3100S<br />

JB3125S<br />

JB3150S<br />

JB3175S<br />

JB3200S<br />

JB3225S<br />

JB3250S<br />

JB3070W<br />

JB3090W<br />

JB3100W<br />

JB3125W<br />

JB3150W<br />

JB3175W<br />

JB3200W<br />

JB3225W<br />

JB3250W<br />

JB3070SW<br />

JB3090SW<br />

JB3100SW<br />

JB3125SW<br />

JB3150SW<br />

JB3175SW<br />

JB3200SW<br />

JB3225SW<br />

JB3250SW<br />

Approx. ship. wt. 14 lbs. Approx. ship. wt. 12 lbs.<br />

JB3700SMW<br />

JB31250SMW<br />

JB31500SMW<br />

JB31750SMW<br />

JB32250SMW<br />

JB32500SMW<br />

Underwriters’ Laboratories, Inc. Listed<br />

Interrupting Ratings➎<br />

Max. Volts Amperes<br />

240 AC<br />

480 AC<br />

600 AC<br />

250 DC<br />

30,000 Asym., 25,000 Sym.<br />

25,000 Asym., 22,000 Sym.<br />

15,000 Asym., 14,000 Sym.<br />

10,000<br />

For all 3-phase Delta, grounded B phase<br />

applications, contact your local Cutler-<br />

Hammer Field Sales Office.<br />

Terminals➊<br />

Two terminals are required per pole.<br />

Terminals are Underwriters’ Laboratories,<br />

Inc. listed for wire type and range listed<br />

right. When used with aluminum conduc-<br />

➊ Terminals are shipped separately from breaker frame.<br />

➋ Not listed with Underwriters’ Laboratories, Inc.<br />

➌ 2-pole <strong>breakers</strong> are supplied in 3-pole frames with current carrying parts omitted from center pole.<br />

➍ Select desired terminal from table and order as separate item.<br />

➎ Ratings above 10,000 amperes not UL listed.<br />

tors, use joint compound. To order<br />

optional copper only terminals, add suffix<br />

“C” to complete breaker catalog number.<br />

Max.<br />

Amps<br />

JB: 600 Volts AC;<br />

250 Volts DC<br />

Catalog<br />

Number<br />

No. of Cables,<br />

Wire Range, Type<br />

Standard Al/Cu Pressure Terminals<br />

250 TA250KB (1) #4-350 MCM Al/Cu<br />

Optional Pressure Terminals<br />

250 T250KB (1) #4-350 MCM Cu<br />

Magnetic Only Breakers<br />

For description, refer to Application Data<br />

29-160.<br />

Additional Accessories and Modifications<br />

Refer to pages 58-68.<br />

March 2001