molded case circuit breakers - Eaton Canada
molded case circuit breakers - Eaton Canada
molded case circuit breakers - Eaton Canada
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
24<br />
Continuous<br />
Ampere<br />
Rating<br />
at 40°C<br />
Continuous<br />
Ampere<br />
Rating<br />
at 40°C<br />
250<br />
250<br />
250<br />
250<br />
250<br />
250<br />
Magnetic Trip Setting,<br />
Amperes (Set on High<br />
Side, Adjustable to<br />
Lower Limits)<br />
Low High<br />
2-Poles, 600 Volts AC, 250 Volts DC➌<br />
70<br />
90<br />
100<br />
125<br />
150<br />
175<br />
200<br />
225<br />
250<br />
350<br />
450<br />
500<br />
625<br />
750<br />
875<br />
1000<br />
1125<br />
1250<br />
3-Poles, 600 Volts AC Only<br />
70<br />
90<br />
100<br />
125<br />
150<br />
175<br />
200<br />
225<br />
250<br />
MOLDED CASE CIRCUIT BREAKERS<br />
Replacement Circuit Breakers<br />
REPLACEMENT CAPABILITIES, Continued<br />
Type JB 90-250 Amperes, 600 Volts AC, 250 Volts DC, 2- and 3 -Poles, Fixed Trip, Thermal Magnetic, Saf-T-Vue<br />
350<br />
450<br />
500<br />
625<br />
750<br />
875<br />
1000<br />
1125<br />
1250<br />
Magnetic Trip Setting,<br />
Amperes (Set on High<br />
Side, Adjustable to<br />
Lower Limits)<br />
Low High<br />
350<br />
625<br />
750<br />
875<br />
1125<br />
1250<br />
700<br />
900<br />
1000<br />
1250<br />
1500<br />
1750<br />
2000<br />
2250<br />
2500<br />
700<br />
900<br />
1000<br />
1250<br />
1500<br />
1750<br />
2000<br />
2250<br />
2500<br />
700<br />
1250<br />
1500<br />
1750<br />
2250<br />
2500<br />
Complete Breaker<br />
Includes Pressure Type<br />
Aluminum Terminals➊<br />
Standard Saf-T-Vue➋<br />
Catalog Numbers<br />
JB2070<br />
JB2090<br />
JB2100<br />
JB2125<br />
JB2150<br />
JB2175<br />
JB2200<br />
JB2225<br />
JB2250<br />
Breaker Only, No Terminals➍<br />
2-Poles➌<br />
Standard Saf-T-Vue<br />
Catalog Numbers<br />
JB2700MW<br />
JB21250MW<br />
JB21500MW<br />
JB21750MW<br />
JB22250MW<br />
JB22500MW<br />
JB2070S<br />
JB2090S<br />
JB2100S<br />
JB2125S<br />
JB2150S<br />
JB2175S<br />
JB2200S<br />
JB2225S<br />
JB2250S<br />
JB2700SMW<br />
JB21250SMW<br />
JB21500SMW<br />
JB21750SMW<br />
JB22250SMW<br />
JB22500SMW<br />
Breaker Without Terminals<br />
Standard Saf-T-Vue➋<br />
JB2070W<br />
JB2090W<br />
JB2100W<br />
JB2125W<br />
JB2150W<br />
JB2175W<br />
JB2200W<br />
JB2225W<br />
JB2250W<br />
3-Poles<br />
Standard Saf-T-Vue<br />
JB3700MW<br />
JB31250MW<br />
JB31500MW<br />
JB31750MW<br />
JB32250MW<br />
JB32500MW<br />
JB2070SW<br />
JB2090SW<br />
JB2100SW<br />
JB2125SW<br />
JB2150SW<br />
JB2175SW<br />
JB2200SW<br />
JB2225SW<br />
JB2250SW<br />
Approx. ship. wt. 12 lbs. Approx. ship. wt. 12 lbs.<br />
JB3070<br />
JB3090<br />
JB3100<br />
JB3125<br />
JB3150<br />
JB3175<br />
JB3200<br />
JB3225<br />
JB3250<br />
Magnetic Only Breakers, Front Adjustable ➋<br />
Accessories and Modifications<br />
Special Calibrations➋<br />
Special calibration price additions apply to<br />
ampere ratings not listed as standard or<br />
for ambients other than 40°C or 50°C. For<br />
frequencies other than 0-60 Hz AC, refer to<br />
Cutler-Hammer.<br />
50°C Calibration➋<br />
Add suffix “V” to catalog number for complete<br />
breaker when ordering <strong>breakers</strong> to<br />
be used in 50°C ambients. Same price as<br />
standard 40°C <strong>breakers</strong>.<br />
For CSA, see page 41.<br />
Type JB <strong>breakers</strong> meet requirements of<br />
Class 19a <strong>circuit</strong> <strong>breakers</strong> as defined by<br />
Federal Specification W-C-375b.<br />
JB3070S<br />
JB3090S<br />
JB3100S<br />
JB3125S<br />
JB3150S<br />
JB3175S<br />
JB3200S<br />
JB3225S<br />
JB3250S<br />
JB3070W<br />
JB3090W<br />
JB3100W<br />
JB3125W<br />
JB3150W<br />
JB3175W<br />
JB3200W<br />
JB3225W<br />
JB3250W<br />
JB3070SW<br />
JB3090SW<br />
JB3100SW<br />
JB3125SW<br />
JB3150SW<br />
JB3175SW<br />
JB3200SW<br />
JB3225SW<br />
JB3250SW<br />
Approx. ship. wt. 14 lbs. Approx. ship. wt. 12 lbs.<br />
JB3700SMW<br />
JB31250SMW<br />
JB31500SMW<br />
JB31750SMW<br />
JB32250SMW<br />
JB32500SMW<br />
Underwriters’ Laboratories, Inc. Listed<br />
Interrupting Ratings➎<br />
Max. Volts Amperes<br />
240 AC<br />
480 AC<br />
600 AC<br />
250 DC<br />
30,000 Asym., 25,000 Sym.<br />
25,000 Asym., 22,000 Sym.<br />
15,000 Asym., 14,000 Sym.<br />
10,000<br />
For all 3-phase Delta, grounded B phase<br />
applications, contact your local Cutler-<br />
Hammer Field Sales Office.<br />
Terminals➊<br />
Two terminals are required per pole.<br />
Terminals are Underwriters’ Laboratories,<br />
Inc. listed for wire type and range listed<br />
right. When used with aluminum conduc-<br />
➊ Terminals are shipped separately from breaker frame.<br />
➋ Not listed with Underwriters’ Laboratories, Inc.<br />
➌ 2-pole <strong>breakers</strong> are supplied in 3-pole frames with current carrying parts omitted from center pole.<br />
➍ Select desired terminal from table and order as separate item.<br />
➎ Ratings above 10,000 amperes not UL listed.<br />
tors, use joint compound. To order<br />
optional copper only terminals, add suffix<br />
“C” to complete breaker catalog number.<br />
Max.<br />
Amps<br />
JB: 600 Volts AC;<br />
250 Volts DC<br />
Catalog<br />
Number<br />
No. of Cables,<br />
Wire Range, Type<br />
Standard Al/Cu Pressure Terminals<br />
250 TA250KB (1) #4-350 MCM Al/Cu<br />
Optional Pressure Terminals<br />
250 T250KB (1) #4-350 MCM Cu<br />
Magnetic Only Breakers<br />
For description, refer to Application Data<br />
29-160.<br />
Additional Accessories and Modifications<br />
Refer to pages 58-68.<br />
March 2001