06.03.2013 Views

molded case circuit breakers - Eaton Canada

molded case circuit breakers - Eaton Canada

molded case circuit breakers - Eaton Canada

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

March 2001<br />

CONTACTORS AND STARTERS<br />

Definite Purpose<br />

PRODUCT HISTORY TIMELINE FOR DEFINITE PURPOSE, BULLETIN 9560, 9584 AND 9586➊<br />

163<br />

Originally a Cutler-Hammer Product<br />

Poles Amperes 1955 1960 1965 1970 1975 1980 1985 1990 1995 1997<br />

9560 Contactors<br />

2P, 3P, 4P 25, 30, 40A<br />

2P, 3P<br />

Contact Kits for Types 9560, 9584, 9586<br />

Description Contact Kit Part Number<br />

Contactor or Starter Size, Amperes<br />

12 Inductive 25, 30 Inductive 40 Inductive<br />

15 Resistive 30, 40 Resistive 50 Resistive<br />

Auxiliary Contact (1 NO – 1 NC) . . . . . . . . . . . . . . . . . . . . . . . . . . .<br />

Auxiliary Contact (1 NO – 1 NO) . . . . . . . . . . . . . . . . . . . . . . . . . . .<br />

2-pole<br />

➋<br />

6-331-10<br />

6-331-11<br />

2-pole w/Quick Connect Terminals . . . . . . . . . 6-331-9<br />

. . . . . . . . .<br />

3-pole<br />

➋<br />

6-331-15<br />

6-331-16<br />

3-pole w/Quick Connect Terminals . . . . . . . . . 6-331-14<br />

. . . . . . . . .<br />

4-pole<br />

➋<br />

6-331-20<br />

6-331-21<br />

4-pole w/Quick Connect Terminals . . . . . . . . . 6-331-19<br />

. . . . . . . . .<br />

Magnetic Coils for Types 9560, 9584, 9586<br />

Coil<br />

Suffix<br />

-7<br />

-47<br />

-49<br />

-50<br />

-69<br />

-72<br />

-74<br />

Coil Voltage Coil Part Number<br />

Ampere Rating<br />

60 Hz 50 Hz 12, 25 and 30 Inductive<br />

15, 30 and 40 Resistive<br />

. . . .<br />

277<br />

104 – 120<br />

208 – 240<br />

24<br />

480<br />

600<br />

380<br />

. . . .<br />

104 – 120<br />

208 – 240<br />

24<br />

480<br />

600<br />

➋<br />

➋<br />

➋<br />

➋<br />

➋<br />

➋<br />

➋<br />

40 Inductive<br />

50 Resistive<br />

➋<br />

➋<br />

9-1814-21<br />

9-1814-8<br />

9-1814-1<br />

Type A25 C25 C32 B25<br />

9560 Contactors<br />

. . . . . . . . . 15 Thru 90A 120 Thru 350A . . . . . . . . .<br />

9584 Starters<br />

9586 Starters<br />

50, 60A<br />

2P, 3P 75, 90A<br />

9584 Starters<br />

1P 30A<br />

40A<br />

50A<br />

60A<br />

9586 Starters<br />

1P 30A<br />

40A<br />

50A<br />

60A<br />

REPLACEMENT CAPABILITIES<br />

TECHNOLOGY UPGRADES<br />

. . . . . . . . .<br />

25 Thru 60A<br />

➊ Use for ampere rated starters/contactors only.<br />

➋ Obsolete.<br />

. . . . . . . . .<br />

. . . . . . . . .<br />

. . . . . . . . .<br />

. . . . . . . . .<br />

➋<br />

➋<br />

25 Thru 40A<br />

. . . . . . . . .<br />

50, 60 Inductive<br />

60, 75 Resistive<br />

10-3654<br />

10-3654-5<br />

6-331-38<br />

. . . . . . . . .<br />

6-331-39<br />

. . . . . . . . .<br />

. . . . . . . . .<br />

. . . . . . . . .<br />

75 Inductive<br />

90 Resistive<br />

10-3654<br />

10-3654-5<br />

6-331-13<br />

. . . . . . . . .<br />

6-331-18<br />

. . . . . . . . .<br />

. . . . . . . . .<br />

. . . . . . . . .<br />

50, 60, 75 and 90 Inductive<br />

60, 75, 90 and 120 Resistive<br />

➋<br />

➋<br />

9-1518-22<br />

➋<br />

➋<br />

➋<br />

➋<br />

90 Inductive<br />

120 Resistive<br />

10-3654<br />

10-3654-5<br />

6-331-24<br />

. . . . . . . . .<br />

6-331-25<br />

. . . . . . . . .<br />

. . . . . . . . .<br />

. . . . . . . . .<br />

K

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!