BUSWAY (LOW VOLTAGE)<br />
Standard and Low Impedance<br />
Plug-in Busway – Fusible Units<br />
REPLACEMENT CAPABILITIES, Continued<br />
Originally a Westinghouse Product<br />
Fusible Plug-in Units<br />
For Standard Plug-in and Low Impedance<br />
Plug-in Busway (Not for use on<br />
Pow-R-Way Busway)<br />
Fusible TAP<br />
Fusible Switch Horsepower Ratings<br />
Ampere<br />
Rating<br />
240 Volts 480 Volts 600 Volts<br />
NEC<br />
Std.<br />
Time<br />
Delay<br />
NEC<br />
Std.<br />
Time<br />
Delay<br />
Fuses not included, mechanical lugs only.<br />
Plug-in unit, neutral, and ground ordered separately and shipped unassembled.<br />
Ampere<br />
Rating<br />
30<br />
60<br />
100<br />
200<br />
400<br />
600<br />
800<br />
30<br />
60<br />
100<br />
200<br />
400<br />
600<br />
3<br />
1 7 ⁄ 2<br />
1 7 ⁄ 2 15<br />
15 30<br />
25 60<br />
50 100<br />
75 100<br />
5<br />
15<br />
25<br />
50<br />
100<br />
200<br />
600 Volts 240 Volts Neutral (If Required) Ground (If Required) Class R Fuse Clips (If Required)<br />
Standard Plug-in Low Impedance 600 Volts 240 Volts<br />
Catalog Number<br />
TAP361<br />
TAP362<br />
TAP363<br />
TAP364<br />
TAP365<br />
TAP366<br />
➍<br />
TAP321<br />
TAP322<br />
TAP323<br />
TAP324<br />
TAP325<br />
TAP326<br />
➍<br />
N110<br />
N110<br />
N110<br />
N250KB<br />
N400<br />
N400➋<br />
ZN110<br />
ZN110<br />
ZN110<br />
ZN250KB<br />
ZN400<br />
➌<br />
15<br />
30<br />
60<br />
125<br />
250<br />
400<br />
NEC<br />
Std.<br />
1 7 ⁄ 2<br />
15<br />
30<br />
60<br />
125<br />
200<br />
Special Industry Fusible Plug-in Units<br />
Special industry plugs are I2t<br />
rated. Knockouts are not provided.<br />
Grounding lug included on 200A and above. Lugs ordered and shipped separately. Fuses are not included.<br />
If neutral or ground assembly required, refer to Cutler-Hammer/Westinghouse Busway.<br />
3-Wire, 600 Volt Plug-in Unit Neutral<br />
(If Required)<br />
Ampere<br />
Rating<br />
30<br />
60<br />
100<br />
200<br />
400<br />
600<br />
Ground<br />
(If Required)<br />
Catalog Number Catalog<br />
Number<br />
TAP361H<br />
TAP362H<br />
TAP363H<br />
TAP364H<br />
TAP365H<br />
TAP366H<br />
➌<br />
➌<br />
➌<br />
➌<br />
➌<br />
➌<br />
Ground Detector and Neutralizer Plug<br />
3-Wire<br />
Catalog Number Maximum Volts<br />
GND36 600<br />
Normally available from stock.<br />
➌<br />
➌<br />
➌<br />
➌<br />
➌<br />
➌<br />
Time<br />
Delay<br />
20<br />
50<br />
75<br />
150<br />
350<br />
500<br />
GS104➊<br />
GS104➊<br />
GS104➊<br />
GS104➊<br />
GS104➊<br />
➌<br />
RFK161<br />
RFK262<br />
RFK464<br />
RFK464<br />
RFK666<br />
RFK666<br />
Terminal Kits for Industry Fusible Plug-in Units<br />
Mechanical Lugs Compression Lugs<br />
MTK30SC<br />
MTK160SC<br />
MTK160SC<br />
MTK200SC<br />
MTK400DPW<br />
MTK600DFW<br />
Lugs Per<br />
Phase<br />
1<br />
1<br />
1<br />
1<br />
2<br />
2<br />
Wire Size Catalog<br />
Number<br />
#14 to #4<br />
#14 to 1/0<br />
#14 to 1/0<br />
#6-350MCM<br />
#2 to 4/0<br />
500 MCM<br />
➊ Not available for low impedance busduct.<br />
➋ Only half neutral available. For full neutral use a TAP366BO or TAP326BO unit.<br />
➌ Must be factory assembled. Order by description.<br />
➍ For units mounting on all feeder type ducts, see the Busway section of the Quick Selector Catalog 25-000.<br />
CTK30SC<br />
CTK60SC<br />
CTK100SC<br />
CTK200BSC<br />
CTK400SPW<br />
CTK600DPM<br />
Lugs Per<br />
Phase<br />
1<br />
1<br />
1<br />
1<br />
1<br />
2<br />
RFK121<br />
RFK222<br />
RFK464<br />
RFK464<br />
RFK666<br />
RFK666<br />
Wire Size<br />
#12 to #10<br />
#8<br />
#4<br />
2/0<br />
750 MCM<br />
500 MCM<br />
March 2001