ACCESSORIES, Continued<br />

Motor Operators➊<br />

Motor operators provide complete remote<br />

control by means of a pushbutton or similar<br />

pilot device➋.<br />

Positive switching action<br />

is accomplished by use of an operating<br />

arm engaging the breaker handle. The unit<br />

is energized momentarily to actuate the<br />

lever arm moving it to either the “ON” or<br />

“OFF” position. The control is broken by<br />

an internal cutoff switch. Means for emergency<br />

manual operations is provided.<br />

Motor operations are available with<br />

motors rated 120 volts AC, 208 volts AC,<br />

and 240 volts AC. ➌<br />

The 480 volt operators utilize a 120 volt AC<br />

motor in conjunction with a 480/240 to 120<br />

volt dual voltage transformer. (On LA and<br />

larger operators, the transformer is supplied<br />

for separate mounting by the customer.)<br />

NOTE: The motor operator is intended<br />

only for infrequent operation in line with<br />

Underwriters’ Laboratories, Inc. endurance<br />

standards for AB <strong>molded</strong> <strong>case</strong> <strong>breakers</strong>.<br />

Minimum 1 kVA transformer is required<br />

for use with all motor operations.<br />

Back Mounting Plates<br />

Type<br />

Breaker<br />

EB, EHB, FB, HFB<br />

DA, JA, KA, LB<br />

JB, KB, HKB<br />

Motor Operator Selection<br />

Type<br />

Breaker<br />

EB, EHB, FB, HFB<br />

DA, JA, KA, HKA<br />

LB, LBB, HLB<br />

JB, KB, HKB<br />

LAB, LA, HLA, LC, HLC<br />

MA, HMA, MC, HMC<br />

NB, HNB, NC, HNC<br />

PB, PC, PCC<br />

Motor Data<br />

Type<br />

Breaker<br />

EB, EHB, FB, HFB<br />

DA, JA, KA, JB, KB, LB,<br />

LBB, HKB, HLB<br />

LAB, LA, HLA<br />

MA, HMA, NB, HNB<br />

PB<br />

March 2001<br />

MOLDED CASE CIRCUIT BREAKERS<br />

Replacement Circuit Breaker Accessories<br />

120, 208, 240, 480 Volts AC<br />

Style Number<br />

503C707G01<br />

503C981G01<br />

1250C26G01<br />

For LAB, LA, HLA<br />

Breakers<br />

For MA, HMA, NB,<br />

HNB Breakers<br />

AC Voltage DC Voltage<br />

120 208 240 480 125 24<br />

Style Number Style Number Style Number Style Number Style Number Style Number<br />

656D148G11<br />

657D819G23<br />

657D819G25<br />

2600D28G07<br />

2607D97G37<br />

5664D54G75<br />

1494D60G31<br />

5661D52G01<br />

656D148G04<br />

657D819G10<br />

657D819G16<br />

2600D28G04<br />

2607D97G40<br />

5664D54G78<br />

1494D60G32<br />

5661D52G04<br />

Motor Inrush Current,<br />

Ampere (Peak)<br />

Type HP 120<br />

Volts<br />

Split Phase<br />

Split Phase<br />

Reversing<br />

Reversing<br />

Reversing<br />

1/75<br />

1/50<br />

. . . .<br />

. . . .<br />

. . . .<br />

10<br />

14<br />

8<br />

11<br />

20<br />

208<br />

Volts<br />

4<br />

6<br />

5<br />

7<br />

12<br />

For EB, EHB, FB and HFB<br />

240<br />

Volts<br />

5<br />

7<br />

4<br />

6<br />

11<br />

656D148G02<br />

657D819G08<br />

657D819G14<br />

2600D28G02<br />

2607D97G38<br />

5664D54G76<br />

1494D60G33<br />

5661D52G02<br />

Continuous<br />

Current (RMS)<br />

120<br />

Volts<br />

2.3<br />

3.5<br />

. . .<br />

. . .<br />

. . .<br />

208<br />

Volts<br />

1.17<br />

1.6<br />

. . . .<br />

. . . .<br />

. . . .<br />

656D148G13<br />

657D819G24<br />

657D819G26<br />

2600D28G08<br />

2607D97G39<br />

5664D54G77<br />

1494D60G34<br />

5661D52G03<br />

Operating<br />

Time, Open<br />

or Close<br />

For DA, JA, KA, JB, LB, LBB, HKA,<br />

HKB and HLB Breakers<br />

. . . . . . . . . . .<br />

. . . . . . . . . . .<br />

. . . . . . . . . . .<br />

. . . . . . . . . . .<br />

2607D97G51<br />

5664D54G96<br />

1494D60G35<br />

5661D52G17<br />

. . . . . . . . . . .<br />

. . . . . . . . . . .<br />

. . . . . . . . . . .<br />

. . . . . . . . . . .<br />

2607D97G42<br />

5664D54G81<br />

1494D60G36<br />

. . . . . . . . . . .<br />

➊ AC voltage rated operators are UL listed as recognized components.<br />

➋ The pilot device must be maintained contact type for EB, EHB, FB, HFB, DA, JA, KA, JB, KB, HKB and LB mechanisms, momentary contact type for all others.<br />

➌ LA and larger available for 125 volts DC.<br />

240<br />

Volts<br />

1.65<br />

1.75<br />

. . . .<br />

. . . .<br />

. . . .<br />

1.5 Seconds<br />

1.5 Seconds<br />

12 Cycles<br />

12 Cycles<br />

10 Cycles<br />

For PB Breakers<br />

67<br />

Dimensions: Dimension Sheet 29-170<br />

Low Resolution Photo<br />

A