CATALOG NUMBER<br />

Trip Unit Type<br />

5<br />

Z<br />

6<br />

8<br />

9<br />

March 2001<br />

510 Basic<br />

510 Zone Int.<br />

610<br />

810<br />

910<br />

SWITCHGEAR (TRIP UNIT RETROFIT KITS)<br />

Digitrip RMS Retrofit Kits for Westinghouse<br />

DS Breakers<br />

Protection<br />

D R 6 8 6 6 4 Q 4 4 - T N N N<br />

Sample shown is a Digitrip Retrofit Kit for<br />

a DS-206, with an RMS 810 trip unit, with<br />

LSIG protection, with a 60 Hz Plug, rated<br />

at 250A for a sensor tap of 400A, four sensors<br />

(for a 4-wire ground system) that<br />

have a sensor tap of 400A, and there are<br />

no other features so this is a standard<br />

original kit.<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

LI<br />

LSI<br />

LS<br />

LIG<br />

LSG<br />

LSIG<br />

T Digitrip 510, 610, 810, 910<br />

N<br />

C<br />

No CPT Supplied<br />

Breaker-mounted CPT<br />

N<br />

S<br />

R<br />

Standard Kit<br />

Simplified Cell Harness<br />

Cell Harness Removed<br />

N<br />

U<br />

B<br />

259<br />

Standard Kit<br />

Upgrade Kit from Factory<br />

Modular Mounting➊<br />

Upgrade Kit from Factory Box<br />

Mounting➊<br />

N No Sensors<br />

RP No Rating Plug<br />

N<br />

6<br />

No Rating Plug<br />

50/60 Hz Plug<br />

3<br />

4<br />

Three Sensors<br />

Four Sensors<br />

Cat.<br />

Code<br />

Current Rating<br />

Tap Plug<br />

21 200 100<br />

22 200 200<br />

Code Breaker Frame Description Sensor<br />

Code<br />

Current Rating of Sensor<br />

and Available Taps<br />

32<br />

3Q<br />

33<br />

300<br />

300<br />

300<br />

200<br />

250<br />

300<br />

ALL FRAMES S NO SENSORS PROVIDED 42 400 200<br />

DR6 DS(L)-206 8<br />

6<br />

800<br />

600<br />

4Q<br />

43<br />

44<br />

400<br />

400<br />

400<br />

250<br />

300<br />

400<br />

4 400<br />

63 600 300<br />

3 300<br />

64 600 400<br />

2 200<br />

66 600 600<br />

DRC DS(L)-416 C 1600<br />

84<br />

86<br />

800<br />

800<br />

400<br />

600<br />

T 1200<br />

88 800 800<br />

8 800<br />

T6 1200 600<br />

6<br />

4<br />

600<br />

400<br />

T8<br />

TA<br />

TT<br />

1200<br />

1200<br />

1200<br />

800<br />

1000<br />

1200<br />

3 300<br />

C8 1600 800<br />

DRD DS-420<br />

2<br />

D<br />

200<br />

2000<br />

CA<br />

CT<br />

CC<br />

1600<br />

1600<br />

1600<br />

1000<br />

1200<br />

1600<br />

C 1600<br />

DA 2000 1000<br />

T<br />

8<br />

1200<br />

800<br />

DT<br />

DC<br />

DD<br />

2000<br />

2000<br />

2000<br />

1200<br />

1600<br />

2000<br />

6 600<br />

FC 2400 1600<br />

4 400<br />

FD 2400 2000<br />

3 300<br />

FF 2400 2400<br />

2 200<br />

JC<br />

JD<br />

3200<br />

3200<br />

1600<br />

2000<br />

DRJ DS-632 (Must replace Amptector Sensors) J 3200<br />

JF 3200 2400<br />

F 2400<br />

JJ 3200 3200<br />

DRK DS-840➋ K<br />

J<br />

4000<br />

3200<br />

KD<br />

KP<br />

KJ<br />

4000<br />

4000<br />

4000<br />

2000<br />

2400<br />

3200<br />

KK 4000 4000<br />

This information is subject to change.<br />

Updated pricing and availability information<br />

resides on Fred II. (412-937-6400)<br />

NOTE: At the time of this publication,<br />

the standard trip units for Low<br />

Voltage Digitrip Retrofit Kits<br />

are the RMS 510/610/810/910.<br />

➊ If breaker has been previously retrofitted, call the Digitrip Retrofit Kit Technical Service Center at 1-800-937-5487.<br />

S

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!