126<br />

BUSWAY (LOW VOLTAGE)<br />

Plug-in Units – Used With CP2,<br />

CP3 or CP4 Safetybus Busway<br />

REPLACEMENT CAPABILITIES, Continued<br />

Originally a Cutler-Hammer Product<br />

Fusible Switch Plug-in Units<br />

Class R Fuse Clip Included<br />

Ampere<br />

Max. HP<br />

Catalog<br />

Max. HP<br />

Catalog<br />

Rating<br />

Rating➊<br />

Number<br />

Rating➊➋<br />

Number<br />

240V, 3-Phase, 3-Wire 120-208V, 3-Phase, 4-Wire<br />

30<br />

7<br />

60<br />

100<br />

1 ⁄2<br />

CP4HD321<br />

5<br />

CP4HD421<br />

15<br />

CP4HD322<br />

10<br />

CP4HD422<br />

30<br />

CP4HD323<br />

25<br />

CP4HD423<br />

200<br />

400<br />

600➌<br />

60<br />

100<br />

100<br />

CP4HD324<br />

CP4HD325<br />

CP4HD326<br />

60<br />

250<br />

400<br />

CP4HD424<br />

CP4HD425<br />

CP4HD426<br />

600V, 3-Phase, 3-Wire 277-480V, 3-Phase, 4-Wire<br />

30<br />

60<br />

100<br />

200<br />

400<br />

600➌<br />

20<br />

50<br />

75<br />

100<br />

350<br />

500<br />

CP4HD361<br />

CP4HD362<br />

CP4HD363<br />

CP4HD364<br />

CP4HD365<br />

CP4HD366<br />

15<br />

30<br />

60<br />

100<br />

250<br />

400<br />

CP4HD461<br />

CP4HD462<br />

CP4HD463<br />

CP4HD464<br />

CP4HD465<br />

CP4HD466<br />

NOTE: We have replaced the 3-Phase, 3-Wire plugs with 3-Phase, 4-Wire plugs.<br />

➊ Maximum HP ratings apply when time delay fuses are used.<br />

➋ 120-208V HP ratings are based on 200V motor usage.<br />

➌ Requires two adjacent plug-in outlets that do not span a busway joint.<br />

➍ For ground stab to engage internal ground bus, add suffix “G” to Catalog Number.<br />

➎ Requires two adjacent plug outlets that do not span a busway joint.<br />

➏ Also accepts (2) #1 – 300 kcmil Al/Cu.<br />

Plug-in Cable Tap Boxes<br />

Plug into CP2, CP3 or CP4 Busway➍ – 600A and 800A Size Also Have Bolt-on Clips<br />

Volts Ampere Catalog Approximate Dimensions In Inches Load Lugs Each Phase<br />

Rating Number<br />

Wide High Deep Mounting Clearance Conduit Sizes<br />

Top Front<br />

3-Phase, 3-Wire 225 CP2SB34 15.5 8.1 6.9 6.3 10.5<br />

1<br />

600V<br />

400 CP2SB35 22.3 8.1 7.9 7.0 11.3<br />

Maximum 600 CP2SB36➎ 37.2 15.8 11.7 12.5 16.8<br />

800 CP2SB37➎ 37.2 15.8 11.7 12.5 16.8<br />

1 ⁄2, 2, 21 ⁄2, 3 (1) #6 – 300 kcmil Al/Cu<br />

. . . . . . . . . . . (1) #1/0 – 750 kcmil Al/Cu➏<br />

. . . . . . . . . . . (2) #2 – 600 kcmil Al/Cu<br />

. . . . . . . . . . . (3) #2 – 600 kcmil Al/Cu<br />

3-Phase, 4-Wire 225 CP2SB44 15.5 8.1 6.9 6.3 10.5<br />

1<br />

120/208V 400 CP2SB45 22.3 8.1 7.9 7.0 11.3<br />

or 277/480V 600 CP2SB46➎ 37.2 15.8 11.7 12.5 16.8<br />

100% Neutral 800 CP2SB47➎ 37.2 15.8 11.7 12.5 16.8<br />

1 ⁄2, 2, 21 ⁄2, 3 (1) #6 – 300 kcmil Al/Cu<br />

. . . . . . . . . . . (1) #1/0 – 750 kcmil Al/Cu➏<br />

. . . . . . . . . . . (2) #2 – 600 kcmil Al/Cu<br />

. . . . . . . . . . . (3) #2 – 600 kcmil Al/Cu<br />