HIGH RESISTANCE PULSING GROUND SYSTEM<br />

(LOW VOLTAGE)<br />

Type C-HRG<br />

CUSTOMER REQUIRED INFORMATION<br />

Description<br />

Sales Notes for C-HRG<br />

Price List for C-HRG<br />

Technical Data for C-HRG<br />

Sales Aid for High Resistance Grounding Systems<br />

Instruction Booklet for High Resistance<br />

Grounding System<br />

Cutler-Hammer Quick Selector Catalog<br />

Cutler-Hammer Consulting Application Guide<br />

CAT.71.01.T.E<br />

PRICING INFORMATION<br />

Contact your Local Cutler-Hammer Distributor.<br />

233<br />

Selection Table<br />

A C-HRG High-Resistance Grounding Assembly can be completely described and priced by a nine or ten digit catalog number using the<br />

option codes from column #4.<br />

Catalog Digit Feature Feature Description Option Code Option Description<br />

1 Enclosure<br />

Type<br />

2 Distribution<br />

System<br />

Voltage<br />

3 System<br />

Neutral<br />

Point<br />

4 Distribution<br />

System<br />

Fault<br />

Current<br />

5 Fault<br />

Sensing<br />

6 Audible<br />

Alarm<br />

7 Loss of<br />

Control<br />

Power Alarm<br />

8 Indicating<br />

Lights<br />

9 Wire<br />

Markers<br />

10 Wire<br />

Harness<br />

Length (No<br />

Enclosure<br />

model only)<br />

Free-standing enclosures provide for mounting the grounding<br />

resistors internally. A wall-mounted enclosure requires a<br />

separately-mounted grounding resistor. The “no enclosure”<br />

option includes a door-mounted panel, a control panel and<br />

a separately-mounted resistor assembly. (See Catalog Digit<br />

10 to specify wire harness length.<br />

Voltage of the distribution system.<br />

Choose Wye when the neutral point of the power source is<br />

accessible for direct connection to the grounding resistor.<br />

Choose Delta when there is no neutral, or when the neutral is<br />

not conveniently accessed. See page 2 for complete description.<br />

The distribution system voltage and fault current will<br />

determine the grounding transformer’s primary breaker<br />

for Zig-Zag or Wye-Broken Delta systems. A Wye system<br />

does not require this additional breaker.<br />

Current-sensing.<br />

Voltage-sensing.<br />

Alarm contacts are standard in all assemblies.<br />

A relay is connected across the output of the control<br />

power transformer for customer use.<br />

Standard lights are industrial, oil-tight, full-voltage type.<br />

Optional are the same type lights except with a push-to-test<br />

feature and/or transformer with 6.3V lamp.<br />

Marks all internal wiring for ease of maintenance<br />

Wiring from the door panel plugs to the left edge of the<br />

control panel. Choose a harness length that will allow<br />

for a hinge loop at the edge of the door.<br />

F<br />

S<br />

R<br />

W<br />

N<br />

6<br />

4<br />

3<br />

2<br />

W<br />

Z<br />

D<br />

6<br />

1<br />

2<br />

N<br />

C<br />

D<br />

N<br />

R<br />

N<br />

L<br />

S<br />

L<br />

P<br />

D<br />

T<br />

X<br />

F<br />

H<br />

4<br />

6<br />

8<br />

0<br />

2<br />

Free-standing NEMA 1<br />

Free-standing NEMA 1 with screened vents<br />

Free-standing NEMA 3R<br />

Wall-Mounted NEMA 1<br />

No Enclosure<br />

600V, 60 Hz<br />

480V, 60 Hz<br />

380V, 50 Hz<br />

208-240V, 60 Hz<br />

Wye<br />

Delta (Zig-Zag grounding transformers)<br />

Delta (Wye-Broken Delta grounding<br />

transformers)<br />

Requires <strong>circuit</strong> breaker. See Catalog Digit 4<br />

600V 480V 240V<br />

25kA 65kA 100kA<br />

. . . . 150kA 200kA<br />

200kA 200kA 200kA<br />

Not Applicable (Note: Wye system is rated<br />

for 200kA)<br />

Overcurrent relay<br />

Double-setpoint voltmeter relay<br />

No Audible Alarm<br />

Alarm Horn with Re-Alarm Timer<br />

No Relay<br />

Alarm Relay with 1-NO and 1-NC contact<br />

wired to a terminal block<br />

Standard, incandescent lamps<br />

Standard, LED lamps<br />

Push-to-test, incandescent lamps<br />

Push-to-test, LED lamps<br />

Transformer-type, incandescent lamp<br />

Push-to-test transformer type<br />

Standard nylon flag-type<br />

Heat-shrink sleeve-type<br />

4 foot harness<br />

6 foot harness<br />

8 foot harness<br />

10 foot harness<br />

12 foot harness<br />

Example: F4WNCRNSF<br />

Defines a free-standing NEMA 1 enclosure, 480/60 Hz Wye-connected system, current-sensing control scheme, alarm horn with re-alarm timer,<br />

standard-type incandescent lights, flag-type wire markers.<br />

Accessory: Portable Clamp on Detector with Case (1/2/5/10/20 Ampere Scales with Shorting Switch) [ Option Add Item]<br />