HIGH RESISTANCE PULSING GROUND SYSTEM<br />
(LOW VOLTAGE)<br />
Type C-HRG<br />
CUSTOMER REQUIRED INFORMATION<br />
Description<br />
Sales Notes for C-HRG<br />
Price List for C-HRG<br />
Technical Data for C-HRG<br />
Sales Aid for High Resistance Grounding Systems<br />
Instruction Booklet for High Resistance<br />
Grounding System<br />
Cutler-Hammer Quick Selector Catalog<br />
Cutler-Hammer Consulting Application Guide<br />
CAT.71.01.T.E<br />
PRICING INFORMATION<br />
Contact your Local Cutler-Hammer Distributor.<br />
233<br />
Selection Table<br />
A C-HRG High-Resistance Grounding Assembly can be completely described and priced by a nine or ten digit catalog number using the<br />
option codes from column #4.<br />
Catalog Digit Feature Feature Description Option Code Option Description<br />
1 Enclosure<br />
Type<br />
2 Distribution<br />
System<br />
Voltage<br />
3 System<br />
Neutral<br />
Point<br />
4 Distribution<br />
System<br />
Fault<br />
Current<br />
5 Fault<br />
Sensing<br />
6 Audible<br />
Alarm<br />
7 Loss of<br />
Control<br />
Power Alarm<br />
8 Indicating<br />
Lights<br />
9 Wire<br />
Markers<br />
10 Wire<br />
Harness<br />
Length (No<br />
Enclosure<br />
model only)<br />
Free-standing enclosures provide for mounting the grounding<br />
resistors internally. A wall-mounted enclosure requires a<br />
separately-mounted grounding resistor. The “no enclosure”<br />
option includes a door-mounted panel, a control panel and<br />
a separately-mounted resistor assembly. (See Catalog Digit<br />
10 to specify wire harness length.<br />
Voltage of the distribution system.<br />
Choose Wye when the neutral point of the power source is<br />
accessible for direct connection to the grounding resistor.<br />
Choose Delta when there is no neutral, or when the neutral is<br />
not conveniently accessed. See page 2 for complete description.<br />
The distribution system voltage and fault current will<br />
determine the grounding transformer’s primary breaker<br />
for Zig-Zag or Wye-Broken Delta systems. A Wye system<br />
does not require this additional breaker.<br />
Current-sensing.<br />
Voltage-sensing.<br />
Alarm contacts are standard in all assemblies.<br />
A relay is connected across the output of the control<br />
power transformer for customer use.<br />
Standard lights are industrial, oil-tight, full-voltage type.<br />
Optional are the same type lights except with a push-to-test<br />
feature and/or transformer with 6.3V lamp.<br />
Marks all internal wiring for ease of maintenance<br />
Wiring from the door panel plugs to the left edge of the<br />
control panel. Choose a harness length that will allow<br />
for a hinge loop at the edge of the door.<br />
F<br />
S<br />
R<br />
W<br />
N<br />
6<br />
4<br />
3<br />
2<br />
W<br />
Z<br />
D<br />
6<br />
1<br />
2<br />
N<br />
C<br />
D<br />
N<br />
R<br />
N<br />
L<br />
S<br />
L<br />
P<br />
D<br />
T<br />
X<br />
F<br />
H<br />
4<br />
6<br />
8<br />
0<br />
2<br />
Free-standing NEMA 1<br />
Free-standing NEMA 1 with screened vents<br />
Free-standing NEMA 3R<br />
Wall-Mounted NEMA 1<br />
No Enclosure<br />
600V, 60 Hz<br />
480V, 60 Hz<br />
380V, 50 Hz<br />
208-240V, 60 Hz<br />
Wye<br />
Delta (Zig-Zag grounding transformers)<br />
Delta (Wye-Broken Delta grounding<br />
transformers)<br />
Requires <strong>circuit</strong> breaker. See Catalog Digit 4<br />
600V 480V 240V<br />
25kA 65kA 100kA<br />
. . . . 150kA 200kA<br />
200kA 200kA 200kA<br />
Not Applicable (Note: Wye system is rated<br />
for 200kA)<br />
Overcurrent relay<br />
Double-setpoint voltmeter relay<br />
No Audible Alarm<br />
Alarm Horn with Re-Alarm Timer<br />
No Relay<br />
Alarm Relay with 1-NO and 1-NC contact<br />
wired to a terminal block<br />
Standard, incandescent lamps<br />
Standard, LED lamps<br />
Push-to-test, incandescent lamps<br />
Push-to-test, LED lamps<br />
Transformer-type, incandescent lamp<br />
Push-to-test transformer type<br />
Standard nylon flag-type<br />
Heat-shrink sleeve-type<br />
4 foot harness<br />
6 foot harness<br />
8 foot harness<br />
10 foot harness<br />
12 foot harness<br />
Example: F4WNCRNSF<br />
Defines a free-standing NEMA 1 enclosure, 480/60 Hz Wye-connected system, current-sensing control scheme, alarm horn with re-alarm timer,<br />
standard-type incandescent lights, flag-type wire markers.<br />
Accessory: Portable Clamp on Detector with Case (1/2/5/10/20 Ampere Scales with Shorting Switch) [ Option Add Item]<br />