188<br />

Typical Schematic<br />

CW<br />

P2<br />

TO<br />

QA2<br />

KA2<br />

CA2<br />

VPF<br />

AV1<br />

SYNCHRONOUS MOTOR CONTROL<br />

Brush Type Mark V Solid-State Slipsyn<br />

Class 14-200 Low-Voltage Motor Starters<br />

PRODUCTION DESCRIPTION<br />

Application<br />

Slipsyn magnetic starters provide reliable,<br />

automatic starting of synchronous motors.<br />

Automatic synchronization is provided by<br />

the Mark V Solid-State Field Panel which<br />

assures application of the field at proper<br />

motor speed, and at a favorable angular<br />

position of stator and rotor poles. As a<br />

result, line disturbance resulting from<br />

synchronization is reduced and effective<br />

motor pull-in torque is increased. Application<br />

of DC power to motor field windings<br />

is accomplished without mechanically<br />

moving parts, and the device features a<br />

”soft-turn on“ <strong>circuit</strong> when applying DC<br />

voltage to the motor field.<br />

The solid-state Mark V Slipsyn controller<br />

will provide the following protective<br />

functions:<br />

A. Locked rotor protection<br />

B. Incomplete sequence<br />

C. Failure to synchronize<br />

D. Fuse failure (Mark V)<br />

E. Pull out protection<br />

F. DC current failure protection<br />

The cabinet will contain the following:<br />

1 – Primary starter full voltage or reduced<br />

voltage<br />

1 – Ammeter shunt (when required)<br />

TO<br />

QB2<br />

KB2<br />

CB2<br />

TO<br />

QC2<br />

KC2<br />

CC2<br />

TO<br />

QA1<br />

KA1<br />

CA1<br />

TO<br />

QB1<br />

KB1<br />

CB1<br />

TO<br />

QC1<br />

KC1<br />

CC1<br />

TO<br />

Q4<br />

CQ4<br />

KQ4<br />

(WB)<br />

CB<br />

SYNCHRONIZING AND CONTROL CIRCUIT<br />

AV2<br />

PSC<br />

RLY 1 RLY 3<br />

VR<br />

TO<br />

D1<br />

115<br />

IN-<br />

IN+<br />

ST1<br />

ST2<br />

SQ1<br />

TO 120V CONTROL CIRCUIT<br />

SQ2<br />

1 – Auxiliary relay for main line contactor<br />

(when required) (MX)<br />

1 – Starting and field discharge resistor<br />

(IRES)<br />

1 – Current transformer for AC ammeter<br />

through NEMA Size 4; Sizes 5 and<br />

larger use three current transformers<br />

for overload relays and AC ammeter<br />

1 – Set control <strong>circuit</strong> terminal blocks<br />

3 – Type AN manual reset thermal overload<br />

relay and three heater elements (OL)<br />

1 – Step down exciter transformer –<br />

3 phase (TX)<br />

3 – Primary fuses (3 PRI)<br />

AC<br />

SUPPLY<br />

MX<br />

*<br />

* START<br />

1 1A STOP 2 3<br />

M<br />

M2 M3<br />

L3<br />

L2<br />

L1<br />

PRI FUSE<br />

3 AMP<br />

FLA<br />

L N<br />

3<br />

A<br />

MX F<br />

CB<br />

115<br />

C<br />

B<br />

M<br />

M<br />

M<br />

H1 H2<br />

VA<br />

CPT<br />

X1 X2<br />

M<br />

1L1<br />

1L2<br />

1L3<br />

FLA<br />

11 14<br />

FLT<br />

TDO<br />

WX K<br />

ST1 RLY1K1<br />

ST2<br />

SYTR<br />

TDO<br />

TO<br />

3 PRI<br />

FUSE<br />

OL<br />

OL<br />

OL<br />

SQ1 RLY3<br />

OL<br />

SQ2 K2<br />

ON DELAY<br />

.1-30 SEC<br />

(SET 2 SEC LONGER THAN<br />

FLT<br />

ACCELERATION TIME)<br />

ON DELAY<br />

.1-30 SEC<br />

SY<br />

TR SET @ .5 SEC<br />

3 – Secondary fuses (3 SEC)<br />

1 – SCR power supply panel<br />

1 – Synchronous control board (CB)<br />

3 – MOV for surge protection (MOV)<br />

1 – Starting and field discharge resistor<br />

(when size permits; otherwise provided<br />

for separate mounting)<br />

1 – AC ammeter, panel type (AM)<br />

1 – DC ammeter, panel type (DC AMM)<br />

1 – Exciter field potentiometer (P2)<br />

1 – Field failure relay (FLA)<br />

1 – Incomplete SEQ Timer (FLT)<br />

1 – Start Timer (SYTR)<br />

12<br />

RES<br />

STARTING/DISCHARGE<br />

D1<br />

R1<br />

RESISTOR<br />

1RES<br />

R3<br />

Q4<br />

(-)<br />

VR<br />

SH<br />

DC<br />

AMM FLA<br />

TO CB<br />

(+)<br />

QC1<br />

TO CB TO CB<br />

TO CB<br />

QC1<br />

P<br />

T3<br />

T2<br />

T1<br />

TO CB<br />

QB1<br />

KB1<br />

CB1<br />

TO CB<br />

QA1<br />

KA1<br />

CA1<br />

KC1<br />

CC1<br />

3SEC<br />

FUSE<br />

MOTOR<br />

FIELD<br />

F1 F2<br />

1L31 1L32 1L33<br />

1L21 1L22 1L23<br />

AMPS<br />

1X1 1X3 1X21X4 2X12X3 2X22X4 3X1 3X3 3X2 3X4<br />

TX<br />

1H1 1H2 2H1 2H2 3H1 3H2<br />

1L11<br />

3PRI<br />

FUSE<br />

1L12 1L13<br />

AMPS<br />

1L1 1L2 1L3<br />

TO AC SUPPLY<br />

KC2<br />

CC2<br />

TO CB<br />

QB1<br />

KB2<br />

CB2<br />

TO CB<br />

QA2<br />

Typical Schematic Full Voltage Starter, Class 14-200 Non-Combination Type * Remote Device<br />

KA2<br />

CA2<br />

N<br />

March 2001