molded case circuit breakers - Eaton Canada
molded case circuit breakers - Eaton Canada
molded case circuit breakers - Eaton Canada
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
FUNCTION<br />
Electronic Device IMPACC System Selection Chart<br />
METERING AND<br />
MONITORING<br />
OVERCURRENT<br />
PROTECTION<br />
MOTOR<br />
PROTECTION<br />
OTHER<br />
DEVICES<br />
LOCAL DISPLAY UNITS<br />
IMPACC COMMUNICATIONS<br />
March 2001<br />
Device Name Descriptive<br />
Bulletin<br />
Electrical Parameters<br />
Volts<br />
Volt-Demand<br />
Amperes<br />
Amperes-Demand<br />
Watts<br />
Watt-Demand<br />
Watt-Hours<br />
Vars<br />
Var-Demand<br />
Var-Hours<br />
VA<br />
VA-Demand<br />
VA-Hours<br />
Power Factor<br />
Hertz<br />
Total Harmonic Distortion<br />
Harmonic Distortion<br />
Factors<br />
Min/Max Values<br />
Runtime Event<br />
Count<br />
Cause/Magnitude<br />
of Trip<br />
Starter/Breaker<br />
Contact Status<br />
143<br />
IQ Analyzer 8179 M<br />
⁄C M ⁄C M ⁄C M ⁄C M ⁄C M ⁄C M ⁄C M ⁄C M ⁄C M ⁄C M ⁄C M ⁄C M ⁄C M ⁄C M ⁄C M ⁄C M M M M M ⁄C 1, 4, 5<br />
IQ DP-4000 8170 M<br />
⁄C M M M M M M M M M M M M M M<br />
M<br />
⁄C 1, 4<br />
IQ Data Plus II (< 14.4 kV) 8176 M<br />
⁄C M M M M M M M<br />
IQ Data Plus II HV (> 14.4 kV) 8176<br />
M<br />
⁄C M M M M M M M<br />
IQ Data 8171 M M<br />
IQ Generator 8172 M M M<br />
IQ Energy Sentinel 8178 M M M 3<br />
Digitrip MV 33-750 P<br />
⁄M M M M M ⁄C 1, 2, 3<br />
Digitrip RMS 810 P<br />
⁄M M M M M M M M M ⁄ C 3<br />
Digitrip RMS 910 M P<br />
⁄M M M M M M M M M M ⁄ C 3<br />
Digitrip OPTIM 750 P<br />
⁄M M M M M ⁄ T 1, 2, 3<br />
Digitrip OPTIM 1050 M P<br />
⁄M M M M M M M M M M M M M M ⁄ T 1, 2, 3<br />
IQ 1000 II 8173 M<br />
⁄C<br />
P<br />
⁄M M M M ⁄C<br />
IQ 500 8177<br />
P<br />
⁄M M M M ⁄ T<br />
ADVANTAGE Starter<br />
P<br />
⁄M M M M ⁄ C<br />
AFD Device Panel M M<br />
M<br />
⁄C M M M ⁄ C<br />
M<br />
⁄C<br />
IQ Transfer M<br />
⁄C M M<br />
⁄C M M ⁄C M ⁄C<br />
Addressable Relay II M M M ⁄ C 3<br />
RTD Module M<br />
Central Energy Display II - CED II<br />
(IQ Energy Sentinel)<br />
CENTRAL MONITORING UNIT - CMU<br />
(ADVANTAGE STARTER)<br />
Assemblies Electronic Monitor - AEM II<br />
(Digitrip RMS)<br />
OPTIM Breaker Interface Module - BIM<br />
(Digitrip OPTIM and Digitrip RMS 810<br />
and 910, IQ Energy Sentinel)<br />
IMPACC SYSTEMS<br />
SOFTWARE<br />
HARDWARE<br />
COMMUNICATIONS SYSTEMS (IMPACC)<br />
For New and Existing Electrical Equipment<br />
GENERAL INFORMATION, Continued<br />
8178 D D D<br />
8226 D D D D<br />
8175 D D D D D D D D D<br />
D D D D D D D D D D D D D D D<br />
Standard Software Status/Control/Data Logging Software<br />
Graphic Software Single Line/Equipment Graphic Software<br />
Power Distribution System<br />
Power Analysis Software<br />
Power Quality, System Coordination Software<br />
Network Diagnostic System Operation Diagnostic Software<br />
PONI Transmits Device Data Over Communication Network<br />
CONI Interfaces Network Communication to Personal Computer<br />
MINT Translates Network Communication to RS-232 Protocol<br />
PLC Interface Card Translates Network Communication to PLC Interface<br />
Mod Bus Gateway Translates Network Communication to Mod Bus Protocol<br />
Ethernet Interface Bridge Translates Network Communication to Ethernet Protocol<br />
IQ DC Power Supply Used for IQ Devices That Do Not Directly Accept DC Power<br />
Legend: M = Monitor<br />
C = Contact for Control/Alarm<br />
P = Protection<br />
D = Display Only, Parameters<br />
Monitored by Other Devices<br />
T = Trip Only<br />
Refer to Page 130 of this document.<br />
External I/O<br />
Special<br />
Functions<br />
Special Functions:<br />
1. Download setpoints<br />
2. Enhanced curve shaping<br />
3. Built-in communication<br />
capability<br />
4. Min./Max.<br />
5. CBEMA (2)<br />
I