06.03.2013 Views

molded case circuit breakers - Eaton Canada

molded case circuit breakers - Eaton Canada

molded case circuit breakers - Eaton Canada

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

FUNCTION<br />

Electronic Device IMPACC System Selection Chart<br />

METERING AND<br />

MONITORING<br />

OVERCURRENT<br />

PROTECTION<br />

MOTOR<br />

PROTECTION<br />

OTHER<br />

DEVICES<br />

LOCAL DISPLAY UNITS<br />

IMPACC COMMUNICATIONS<br />

March 2001<br />

Device Name Descriptive<br />

Bulletin<br />

Electrical Parameters<br />

Volts<br />

Volt-Demand<br />

Amperes<br />

Amperes-Demand<br />

Watts<br />

Watt-Demand<br />

Watt-Hours<br />

Vars<br />

Var-Demand<br />

Var-Hours<br />

VA<br />

VA-Demand<br />

VA-Hours<br />

Power Factor<br />

Hertz<br />

Total Harmonic Distortion<br />

Harmonic Distortion<br />

Factors<br />

Min/Max Values<br />

Runtime Event<br />

Count<br />

Cause/Magnitude<br />

of Trip<br />

Starter/Breaker<br />

Contact Status<br />

143<br />

IQ Analyzer 8179 M<br />

⁄C M ⁄C M ⁄C M ⁄C M ⁄C M ⁄C M ⁄C M ⁄C M ⁄C M ⁄C M ⁄C M ⁄C M ⁄C M ⁄C M ⁄C M ⁄C M M M M M ⁄C 1, 4, 5<br />

IQ DP-4000 8170 M<br />

⁄C M M M M M M M M M M M M M M<br />

M<br />

⁄C 1, 4<br />

IQ Data Plus II (< 14.4 kV) 8176 M<br />

⁄C M M M M M M M<br />

IQ Data Plus II HV (> 14.4 kV) 8176<br />

M<br />

⁄C M M M M M M M<br />

IQ Data 8171 M M<br />

IQ Generator 8172 M M M<br />

IQ Energy Sentinel 8178 M M M 3<br />

Digitrip MV 33-750 P<br />

⁄M M M M M ⁄C 1, 2, 3<br />

Digitrip RMS 810 P<br />

⁄M M M M M M M M M ⁄ C 3<br />

Digitrip RMS 910 M P<br />

⁄M M M M M M M M M M ⁄ C 3<br />

Digitrip OPTIM 750 P<br />

⁄M M M M M ⁄ T 1, 2, 3<br />

Digitrip OPTIM 1050 M P<br />

⁄M M M M M M M M M M M M M M ⁄ T 1, 2, 3<br />

IQ 1000 II 8173 M<br />

⁄C<br />

P<br />

⁄M M M M ⁄C<br />

IQ 500 8177<br />

P<br />

⁄M M M M ⁄ T<br />

ADVANTAGE Starter<br />

P<br />

⁄M M M M ⁄ C<br />

AFD Device Panel M M<br />

M<br />

⁄C M M M ⁄ C<br />

M<br />

⁄C<br />

IQ Transfer M<br />

⁄C M M<br />

⁄C M M ⁄C M ⁄C<br />

Addressable Relay II M M M ⁄ C 3<br />

RTD Module M<br />

Central Energy Display II - CED II<br />

(IQ Energy Sentinel)<br />

CENTRAL MONITORING UNIT - CMU<br />

(ADVANTAGE STARTER)<br />

Assemblies Electronic Monitor - AEM II<br />

(Digitrip RMS)<br />

OPTIM Breaker Interface Module - BIM<br />

(Digitrip OPTIM and Digitrip RMS 810<br />

and 910, IQ Energy Sentinel)<br />

IMPACC SYSTEMS<br />

SOFTWARE<br />

HARDWARE<br />

COMMUNICATIONS SYSTEMS (IMPACC)<br />

For New and Existing Electrical Equipment<br />

GENERAL INFORMATION, Continued<br />

8178 D D D<br />

8226 D D D D<br />

8175 D D D D D D D D D<br />

D D D D D D D D D D D D D D D<br />

Standard Software Status/Control/Data Logging Software<br />

Graphic Software Single Line/Equipment Graphic Software<br />

Power Distribution System<br />

Power Analysis Software<br />

Power Quality, System Coordination Software<br />

Network Diagnostic System Operation Diagnostic Software<br />

PONI Transmits Device Data Over Communication Network<br />

CONI Interfaces Network Communication to Personal Computer<br />

MINT Translates Network Communication to RS-232 Protocol<br />

PLC Interface Card Translates Network Communication to PLC Interface<br />

Mod Bus Gateway Translates Network Communication to Mod Bus Protocol<br />

Ethernet Interface Bridge Translates Network Communication to Ethernet Protocol<br />

IQ DC Power Supply Used for IQ Devices That Do Not Directly Accept DC Power<br />

Legend: M = Monitor<br />

C = Contact for Control/Alarm<br />

P = Protection<br />

D = Display Only, Parameters<br />

Monitored by Other Devices<br />

T = Trip Only<br />

Refer to Page 130 of this document.<br />

External I/O<br />

Special<br />

Functions<br />

Special Functions:<br />

1. Download setpoints<br />

2. Enhanced curve shaping<br />

3. Built-in communication<br />

capability<br />

4. Min./Max.<br />

5. CBEMA (2)<br />

I

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!