GENERAL INFORMATION<br />

Accessories and Modifications<br />

All accessories and modifications available<br />

for Type FB and HFB <strong>molded</strong> <strong>case</strong><br />

<strong>circuit</strong> <strong>breakers</strong> are also available for Motor<br />

Control Center replacement <strong>breakers</strong><br />

types RMCFA, RMCHFA, RMCF, and<br />

RMCHF.<br />

Terminal<br />

Breakers include both line and load<br />

terminals. See Terminal Data for<br />

replacement breaker type FB.<br />

50˚C Calibration<br />

Add suffix ”V“ to catalog number for complete<br />

breaker, listed above, when ordering<br />

listed ampere ratings for <strong>breakers</strong> to be<br />

used in 50˚C ambients. Same price as<br />

standard 40˚C <strong>breakers</strong>.<br />

Special Breakers<br />

Magnetic only, front adjustable (includes<br />

line and load terminals). Available for<br />

15-150 ampere ratings for 2- and 3-pole<br />

RMCF, RMCHF, RMCFA and RMCHFA.<br />

Handle Mechanism — Slide Plate Type<br />

The same type of handle mechanism<br />

as was originally used in Westinghouse<br />

Type W and 11-300 Motor Control Centers<br />

continues to be available from<br />

Cutler-Hammer today.<br />

The ”Slide Plate“ handle mechanism was<br />

originally used on the Westinghouse<br />

11-300 Motor Control Center manufactured<br />

from 1935 to 1965. This handle is<br />

still used on replacement units today and<br />

is also vailable as a component.<br />

The MC handle mechanism was used on<br />

the Westinghouse Type W and Cutler-<br />

Hammer 9800 Motor Control Centers<br />

manufactured from 1965 to 1975.<br />

This handle mechanism was also used by<br />

many other OEM‘s such as ITE and Federal<br />

Pacific. The MC handle is also still used on<br />

replacement units today and is available<br />

as a component.<br />

➊ Check VISTA for order entry procedures.<br />

March 2001<br />

MOLDED CASE CIRCUIT BREAKERS<br />

Motor Control Center Replacement<br />

Circuit Breakers<br />

79<br />

Slide Plate Handle Mechanism Selection Charts➊<br />

Enclosure Cover Hinged on Right Vertical Mounting<br />

Padlocks in Padlocks in ON Padlocks in<br />

OFF Position or OFF Position OFF Position<br />

Style Numbers Style Numbers Style Numbers<br />

Circuit Breakers<br />

KL and HKL Frame<br />

MA, HMA, MC and HMC Breaker<br />

LA, HLA, LC and HLC Breaker<br />

JA, KA, HKA, DA, LB, LBB and HLB Breaker<br />

NB, HNB, NC and HNC Breaker<br />

JB, KB and HKB Breaker<br />

LCL Breaker<br />

EH Breaker 2P with long handle<br />

EH Breaker 3P with long handle<br />

F Frame 2P<br />

F and HF Frame 3P<br />

Type AQB and NQB 100A Frames and<br />

Type PF 15-100A Frame<br />

EH Standard 2P<br />

314C386G01 314C386G08 314C386G04<br />

314C386G02 314C386G09 314C386G05<br />

EH Std. 3P and FA magnetic only 2 and 3P<br />

FA 2 and 3P Thermal Magnetic<br />

314C386G03 314C386G10 314C386G06<br />

EB, EHB, FB, HFB 3P<br />

MCP HMCP (0-4)<br />

FCL Breaker<br />

2P<br />

PB, TRI-PAC PB, PC, PCC 505C294G03<br />

Series C Circuit Breakers<br />

F-Frame Series C 314C386G03 314C386G10 314C386G06<br />

J-Frame Series C<br />

K-Frame Series C<br />

314C386G02 314C386G09 314C386G05<br />

L-Frame Series C 314C386G18 314C386G08 314C386G04<br />

R-Frame<br />

Tri-Pac Switches<br />

225A TRI-PAC Type K<br />

505C294G03<br />

400A TRI-PAC Type KL<br />

LA TRI-PAC<br />

NB TRI-PAC<br />

314C386G01 314C386G08 314C386G04<br />

100A TRI-PAC 314C386G02 314C386G09 314C386G05<br />

FB TRI-PAC<br />

Visi-Flex Switches (Model T)<br />

314C386G03 314C386G10 314C386G06<br />

60-100A Visi-Flex 314C386G01 314C386G08 314C386G04<br />

30A and Special 60A Visi-Flex<br />

De-ion Switches and Disconnect Switches<br />

30-60A (long handle) De-ion<br />

314C386G02 314C386G09 314C386G05<br />

100A (long handle) De-ion<br />

200A Disconnect Switch<br />

200 DS Switch<br />

314C386G01 314C386G08 314C386G04<br />

30-60A Disconnect Switch<br />

100A Disconnect Switch<br />

314C386G02 314C386G09 314C386G05<br />

30, 60, 100A DS Switch 314C386G03 314C386G10 314C386G06<br />

400 and 600A DS Switch 314C386G15<br />

A