GENERAL INFORMATION<br />
Accessories and Modifications<br />
All accessories and modifications available<br />
for Type FB and HFB <strong>molded</strong> <strong>case</strong><br />
<strong>circuit</strong> <strong>breakers</strong> are also available for Motor<br />
Control Center replacement <strong>breakers</strong><br />
types RMCFA, RMCHFA, RMCF, and<br />
RMCHF.<br />
Terminal<br />
Breakers include both line and load<br />
terminals. See Terminal Data for<br />
replacement breaker type FB.<br />
50˚C Calibration<br />
Add suffix ”V“ to catalog number for complete<br />
breaker, listed above, when ordering<br />
listed ampere ratings for <strong>breakers</strong> to be<br />
used in 50˚C ambients. Same price as<br />
standard 40˚C <strong>breakers</strong>.<br />
Special Breakers<br />
Magnetic only, front adjustable (includes<br />
line and load terminals). Available for<br />
15-150 ampere ratings for 2- and 3-pole<br />
RMCF, RMCHF, RMCFA and RMCHFA.<br />
Handle Mechanism — Slide Plate Type<br />
The same type of handle mechanism<br />
as was originally used in Westinghouse<br />
Type W and 11-300 Motor Control Centers<br />
continues to be available from<br />
Cutler-Hammer today.<br />
The ”Slide Plate“ handle mechanism was<br />
originally used on the Westinghouse<br />
11-300 Motor Control Center manufactured<br />
from 1935 to 1965. This handle is<br />
still used on replacement units today and<br />
is also vailable as a component.<br />
The MC handle mechanism was used on<br />
the Westinghouse Type W and Cutler-<br />
Hammer 9800 Motor Control Centers<br />
manufactured from 1965 to 1975.<br />
This handle mechanism was also used by<br />
many other OEM‘s such as ITE and Federal<br />
Pacific. The MC handle is also still used on<br />
replacement units today and is available<br />
as a component.<br />
➊ Check VISTA for order entry procedures.<br />
March 2001<br />
MOLDED CASE CIRCUIT BREAKERS<br />
Motor Control Center Replacement<br />
Circuit Breakers<br />
79<br />
Slide Plate Handle Mechanism Selection Charts➊<br />
Enclosure Cover Hinged on Right Vertical Mounting<br />
Padlocks in Padlocks in ON Padlocks in<br />
OFF Position or OFF Position OFF Position<br />
Style Numbers Style Numbers Style Numbers<br />
Circuit Breakers<br />
KL and HKL Frame<br />
MA, HMA, MC and HMC Breaker<br />
LA, HLA, LC and HLC Breaker<br />
JA, KA, HKA, DA, LB, LBB and HLB Breaker<br />
NB, HNB, NC and HNC Breaker<br />
JB, KB and HKB Breaker<br />
LCL Breaker<br />
EH Breaker 2P with long handle<br />
EH Breaker 3P with long handle<br />
F Frame 2P<br />
F and HF Frame 3P<br />
Type AQB and NQB 100A Frames and<br />
Type PF 15-100A Frame<br />
EH Standard 2P<br />
314C386G01 314C386G08 314C386G04<br />
314C386G02 314C386G09 314C386G05<br />
EH Std. 3P and FA magnetic only 2 and 3P<br />
FA 2 and 3P Thermal Magnetic<br />
314C386G03 314C386G10 314C386G06<br />
EB, EHB, FB, HFB 3P<br />
MCP HMCP (0-4)<br />
FCL Breaker<br />
2P<br />
PB, TRI-PAC PB, PC, PCC 505C294G03<br />
Series C Circuit Breakers<br />
F-Frame Series C 314C386G03 314C386G10 314C386G06<br />
J-Frame Series C<br />
K-Frame Series C<br />
314C386G02 314C386G09 314C386G05<br />
L-Frame Series C 314C386G18 314C386G08 314C386G04<br />
R-Frame<br />
Tri-Pac Switches<br />
225A TRI-PAC Type K<br />
505C294G03<br />
400A TRI-PAC Type KL<br />
LA TRI-PAC<br />
NB TRI-PAC<br />
314C386G01 314C386G08 314C386G04<br />
100A TRI-PAC 314C386G02 314C386G09 314C386G05<br />
FB TRI-PAC<br />
Visi-Flex Switches (Model T)<br />
314C386G03 314C386G10 314C386G06<br />
60-100A Visi-Flex 314C386G01 314C386G08 314C386G04<br />
30A and Special 60A Visi-Flex<br />
De-ion Switches and Disconnect Switches<br />
30-60A (long handle) De-ion<br />
314C386G02 314C386G09 314C386G05<br />
100A (long handle) De-ion<br />
200A Disconnect Switch<br />
200 DS Switch<br />
314C386G01 314C386G08 314C386G04<br />
30-60A Disconnect Switch<br />
100A Disconnect Switch<br />
314C386G02 314C386G09 314C386G05<br />
30, 60, 100A DS Switch 314C386G03 314C386G10 314C386G06<br />
400 and 600A DS Switch 314C386G15<br />
A