SLIDE PLATE TYPE<br />

Vertical Mounting<br />

These compact Westinghouse slide plate<br />

handle mechanisms are especially designed<br />

for use with AB De-ion <strong>circuit</strong> <strong>breakers</strong><br />

and disconnect switches when they are<br />

mounted in a shallow enclosure. They are<br />

suitable for use on NEMA 1 applications.<br />

Because of the mechanisms’ simplified<br />

installation – three mounting holes – and<br />

preassembled construction, these units are<br />

commonly used where high volume, standardized<br />

enclosures are being fabricated.<br />

The mechanism styles listed on this page<br />

are for use on enclosures which have covers<br />

hinged on the right side. If these mechanisms<br />

are used on enclosures which<br />

have covers hinged on the left side, the<br />

door interlock will not function.<br />

Outdoor<br />

or Hazardous<br />

Location Type<br />

This handle mechanism is designed for<br />

use with fabricated or cast, NEMA 3, 4 or 5<br />

enclosures. A butterfly cam type mechanism<br />

may be used on enclosures with<br />

either right or left hand hinged covers or<br />

on enclosures with bolted covers. The<br />

mechanism has a provision for padlocking.<br />

Will accept up to three locks. Assembly<br />

of this mechanism is accomplished by<br />

welding it to the enclosure door or cover.<br />

Refer to IL29C287 for drilling plan. For PB,<br />

PC and RD, refer to Drawing 372D690.<br />

ACCESSORIES<br />

Door Interlock Kits<br />

For use with slide plate mechanisms used<br />

in larger panels where regular interlock is<br />

not adequate.<br />

Style Number Description Drilling Plan<br />

Reference<br />

28A2656G08<br />

1532990<br />

March 2001<br />

Horizontal Mounting<br />

3 point –<br />

For mechanisms,<br />

style numbers:<br />

314C386G01, 02,<br />

03, 04, 05, 06, 08,<br />

09 and 10<br />

2 point –<br />

For PB mechanism,<br />

style<br />

number<br />

505C294G03<br />

MOLDED CASE CIRCUIT BREAKERS<br />

Handle Mechanisms<br />

208B624<br />

372D690<br />

➊ Handle mechanisms cannot be used on<br />

Visi-flex switches with 200 ampere fuse kits.<br />

➋ Does not padlock in OFF position. NEMA 3R<br />

version available as special. Contact your<br />

Cutler-Hammer representative.<br />

CATALOG NUMBERS<br />

Standard Slide Plate Mechanisms<br />

Enclosure Cover<br />

Hinged on Right<br />

Circuit Breakers<br />

KL and HKL Frame<br />

MA, HMA, MC and HMC Breaker<br />

LA, HLA, LC and HLC Breaker<br />

JA, KA, HKA, DA, LB, LBB and HLB Breaker<br />

NB, HNB, NC and HNC Breaker<br />

JB, KB and HKB Breaker<br />

LCL Breaker<br />

EH Breaker 2P with long handle<br />

EH Breaker 3P with long handle<br />

F Frame 2P<br />

F and HF Frame 3P<br />

Type AQB and NQB 100A Frames and<br />

Type PF 15-100A Frame<br />

EH Standard 2P<br />

85<br />

Vertical Mounting Horizontal Mounting<br />

Padlocks in<br />

OFF Position<br />

Padlocks in ON or<br />

OFF Position<br />

Padlocks in<br />

OFF Position<br />

Style Number Style Number Style Number<br />

314C386G01 314C386G08 314C386G04<br />

314C386G02 314C386G09 314C386G05<br />

EH Standard 3P and FA mag only 2 and 3P<br />

FA 2 and 3P Thermal Mag<br />

EB, EHB, FB, HFB 3P<br />

MCP, HMCP (0-4) 2P<br />

FCL Breaker<br />

314C386G03 314C386G10 314C386G06<br />

PB, TRI-PAC PB, PC, PCC, PCF<br />

Series C Circuit Breakers<br />

505C294G03 . . . . . . . . . . . . . . . . . . . . . . . . . .<br />

F-Frame Series C + HMCP-F 314C386G03 314C386G10 314C386G06<br />

J-Frame Series C + HMCP-J<br />

K-Frame Series C + HMCP-K<br />

314C386G02 314C386G09 314C386G05<br />

L-Frame Series C + HMCP-L 314C386G18 314C386G08 314C386G04<br />

M-Frame Series C 314C386G01 314C386G08 314C386G04<br />

R-Frame➋<br />

TRI-PAC Switches<br />

225A TRI-PAC Type K<br />

505C294G03 . . . . . . . . . . . . . . . . . . . . . . . . . .<br />

400A TRI-PAC Type KL<br />

LA TRI-PAC<br />

NB TRI-PAC<br />

314C386G01 314C386G08 314C386G04<br />

100A TRI-PAC 314C386G02 314C386G09 314C386G05<br />

FB TRI-PAC<br />

Visi-Flex Switches (Model T)➊<br />

314C386G03 314C386G10 314C386G06<br />

60-100A Visi-Flex 314C386G01 314C386G08 314C386G04<br />

30A and Special 60A Visi-Flex<br />

De-ion Switches and Disconnect Switches<br />

30-60A (long handle) De-ion<br />

314C386G02 314C386G09 314C386G05<br />

100A (long handle) De-ion<br />

200A Disconnect Switch<br />

200 DS Switch<br />

314C386G01 314C386G08 314C386G04<br />

30-60A Disconnect Switch<br />

100A Disconnect Switch<br />

314C386G02 314C386G09 314C386G05<br />

30, 60, 100A DS Switch 314C386G03 314C386G10 314C386G06<br />

400 and 600A DS Switch 314C386G15 . . . . . . . . . . . . . . . . . . . . . . . . . .<br />

Mechanisms for Outdoor or Hazardous Locations<br />

Description Complete Handle Mechanisms NEMA 3, 4, 5 Drilling<br />

Padlocks in<br />

OFF Position<br />

Padlocks in ON or<br />

OFF Position<br />

Plan<br />

Reference<br />

Style Number Style Number<br />

Circuit Breakers<br />

Series C F Frame EB, EHB, FB, HFB<br />

48A3656G03<br />

48A3656G04<br />

48A3656<br />

JA, KA, LA, MA, HKA, HLA, HMA, LB, HLB<br />

De-ion Switches<br />

452D028G01<br />

. . . . . . . . . . . . . 452D028<br />

30, 60, 100 Amp 48A3656G03 48A3656G04 48A3656<br />