SLIDE PLATE TYPE<br />
Vertical Mounting<br />
These compact Westinghouse slide plate<br />
handle mechanisms are especially designed<br />
for use with AB De-ion <strong>circuit</strong> <strong>breakers</strong><br />
and disconnect switches when they are<br />
mounted in a shallow enclosure. They are<br />
suitable for use on NEMA 1 applications.<br />
Because of the mechanisms’ simplified<br />
installation – three mounting holes – and<br />
preassembled construction, these units are<br />
commonly used where high volume, standardized<br />
enclosures are being fabricated.<br />
The mechanism styles listed on this page<br />
are for use on enclosures which have covers<br />
hinged on the right side. If these mechanisms<br />
are used on enclosures which<br />
have covers hinged on the left side, the<br />
door interlock will not function.<br />
Outdoor<br />
or Hazardous<br />
Location Type<br />
This handle mechanism is designed for<br />
use with fabricated or cast, NEMA 3, 4 or 5<br />
enclosures. A butterfly cam type mechanism<br />
may be used on enclosures with<br />
either right or left hand hinged covers or<br />
on enclosures with bolted covers. The<br />
mechanism has a provision for padlocking.<br />
Will accept up to three locks. Assembly<br />
of this mechanism is accomplished by<br />
welding it to the enclosure door or cover.<br />
Refer to IL29C287 for drilling plan. For PB,<br />
PC and RD, refer to Drawing 372D690.<br />
ACCESSORIES<br />
Door Interlock Kits<br />
For use with slide plate mechanisms used<br />
in larger panels where regular interlock is<br />
not adequate.<br />
Style Number Description Drilling Plan<br />
Reference<br />
28A2656G08<br />
1532990<br />
March 2001<br />
Horizontal Mounting<br />
3 point –<br />
For mechanisms,<br />
style numbers:<br />
314C386G01, 02,<br />
03, 04, 05, 06, 08,<br />
09 and 10<br />
2 point –<br />
For PB mechanism,<br />
style<br />
number<br />
505C294G03<br />
MOLDED CASE CIRCUIT BREAKERS<br />
Handle Mechanisms<br />
208B624<br />
372D690<br />
➊ Handle mechanisms cannot be used on<br />
Visi-flex switches with 200 ampere fuse kits.<br />
➋ Does not padlock in OFF position. NEMA 3R<br />
version available as special. Contact your<br />
Cutler-Hammer representative.<br />
CATALOG NUMBERS<br />
Standard Slide Plate Mechanisms<br />
Enclosure Cover<br />
Hinged on Right<br />
Circuit Breakers<br />
KL and HKL Frame<br />
MA, HMA, MC and HMC Breaker<br />
LA, HLA, LC and HLC Breaker<br />
JA, KA, HKA, DA, LB, LBB and HLB Breaker<br />
NB, HNB, NC and HNC Breaker<br />
JB, KB and HKB Breaker<br />
LCL Breaker<br />
EH Breaker 2P with long handle<br />
EH Breaker 3P with long handle<br />
F Frame 2P<br />
F and HF Frame 3P<br />
Type AQB and NQB 100A Frames and<br />
Type PF 15-100A Frame<br />
EH Standard 2P<br />
85<br />
Vertical Mounting Horizontal Mounting<br />
Padlocks in<br />
OFF Position<br />
Padlocks in ON or<br />
OFF Position<br />
Padlocks in<br />
OFF Position<br />
Style Number Style Number Style Number<br />
314C386G01 314C386G08 314C386G04<br />
314C386G02 314C386G09 314C386G05<br />
EH Standard 3P and FA mag only 2 and 3P<br />
FA 2 and 3P Thermal Mag<br />
EB, EHB, FB, HFB 3P<br />
MCP, HMCP (0-4) 2P<br />
FCL Breaker<br />
314C386G03 314C386G10 314C386G06<br />
PB, TRI-PAC PB, PC, PCC, PCF<br />
Series C Circuit Breakers<br />
505C294G03 . . . . . . . . . . . . . . . . . . . . . . . . . .<br />
F-Frame Series C + HMCP-F 314C386G03 314C386G10 314C386G06<br />
J-Frame Series C + HMCP-J<br />
K-Frame Series C + HMCP-K<br />
314C386G02 314C386G09 314C386G05<br />
L-Frame Series C + HMCP-L 314C386G18 314C386G08 314C386G04<br />
M-Frame Series C 314C386G01 314C386G08 314C386G04<br />
R-Frame➋<br />
TRI-PAC Switches<br />
225A TRI-PAC Type K<br />
505C294G03 . . . . . . . . . . . . . . . . . . . . . . . . . .<br />
400A TRI-PAC Type KL<br />
LA TRI-PAC<br />
NB TRI-PAC<br />
314C386G01 314C386G08 314C386G04<br />
100A TRI-PAC 314C386G02 314C386G09 314C386G05<br />
FB TRI-PAC<br />
Visi-Flex Switches (Model T)➊<br />
314C386G03 314C386G10 314C386G06<br />
60-100A Visi-Flex 314C386G01 314C386G08 314C386G04<br />
30A and Special 60A Visi-Flex<br />
De-ion Switches and Disconnect Switches<br />
30-60A (long handle) De-ion<br />
314C386G02 314C386G09 314C386G05<br />
100A (long handle) De-ion<br />
200A Disconnect Switch<br />
200 DS Switch<br />
314C386G01 314C386G08 314C386G04<br />
30-60A Disconnect Switch<br />
100A Disconnect Switch<br />
314C386G02 314C386G09 314C386G05<br />
30, 60, 100A DS Switch 314C386G03 314C386G10 314C386G06<br />
400 and 600A DS Switch 314C386G15 . . . . . . . . . . . . . . . . . . . . . . . . . .<br />
Mechanisms for Outdoor or Hazardous Locations<br />
Description Complete Handle Mechanisms NEMA 3, 4, 5 Drilling<br />
Padlocks in<br />
OFF Position<br />
Padlocks in ON or<br />
OFF Position<br />
Plan<br />
Reference<br />
Style Number Style Number<br />
Circuit Breakers<br />
Series C F Frame EB, EHB, FB, HFB<br />
48A3656G03<br />
48A3656G04<br />
48A3656<br />
JA, KA, LA, MA, HKA, HLA, HMA, LB, HLB<br />
De-ion Switches<br />
452D028G01<br />
. . . . . . . . . . . . . 452D028<br />
30, 60, 100 Amp 48A3656G03 48A3656G04 48A3656<br />
A