How To Select A Retrofit Kit<br />

How To Generate A Catalog Number<br />

How To Price A Kit<br />

SWITCHGEAR (TRIP UNIT RETROFIT KITS)<br />

Customer Required Information<br />

CUSTOMER REQUIRED INFORMATION<br />

To properly select a retrofit kit, the following<br />

information is required:<br />

● Breaker Nameplate Information<br />

– Manufacturer<br />

– Breaker Type<br />

– Ampere Frame Size<br />

– Manually or Electrically Operated<br />

● Drawout or Fixed Mounting<br />

● Fused or Non-Fused<br />

● Digitrip Trip Unit Type Required<br />

– 510, 610, 810, 910<br />

● Protective Functions Required<br />

– LI, LSI, LS, LIG, LSG, LSIG<br />

Refer to pages 255-273 to view the Retrofit<br />

Kit Catalog Numbers for specific breaker<br />

manufacturers and frames. When used in<br />

To correctly price a Low Voltage Digitrip<br />

Retrofit Kit, refer to the Retrofit Kit Product<br />

Guide. It is also available on FRED II<br />

ACCESSORIES<br />

● Continuous Current Rating Required<br />

(Trip Rating of Breaker)<br />

● 3-wire or 4-wire system (determines<br />

number of sensors required)<br />

NOTE: At the time of this publication, the standard trip units for<br />

Low Voltage Digitrip Retrofit Kits are the RMS 510/610/810/<br />

910. From 1989-1996, the standard trip units were the RMS<br />

500/600/700/800. These trip units are no longer in production.<br />

Replacement orders for the 500/600/700/800 trip units<br />

will be filled by the equivalent 510/610/810/910 trip units.<br />

Remember when replacing a 500/600/700/800 unit with a<br />

510/610/810/910, the rating plug must also be replaced.<br />

conjunction with the information obtained<br />

from the section above, these pages con-<br />

(412-937-6400) as Document #9375487.<br />

This Product Guide includes base prices,<br />

Catalog Number Style Number Description<br />

PRTAAPM 1267C16G01 Aux. Power Module<br />

8779C02G02 Amptector and Digitrip Test Set (Tests for both)<br />

6503C53G01 Amptector Adapter Harness<br />

6503C54G01 Amptector 2-Piece Adapter Harness (Test Set Half)<br />

6503C55G01 Amptector 2-Piece Adapter Harness (Breaker Half)<br />

6502C83G01 External Harness (Zone Interlock Shorting Plug)<br />

8259A91G05 Auxiliary CPT Kit (Non-DS)<br />

8259A91G06 Auxiliary CPT Kit (DS)<br />

6506C34G01 Simplified Cell Harness 1 ft.<br />

6506C34G02 Simplified Cell Harness 6 ft.<br />

6506C34G03 Simplified Cell Harness 4 ft.<br />

To properly select options, the following<br />

questions need to be answered:<br />

● Will customer supply 120 VAC control<br />

power or is breaker-mounted CPT<br />

needed?<br />

– applies only to Digitrip 610, 810,<br />

and 910<br />

● Are zone interlocks required?<br />

● Does the application require relay<br />

outputs from the Digitrip 610, 810,<br />

or 910 for remote indication?<br />

● Does the breaker have an existing<br />

Amptector or Digitrip Trip Unit<br />

installed? If so, what is it?<br />

tain all the information necessary to<br />

generate a Catalog Number.<br />

adders and options for all Low Voltage<br />

Digitrip Retrofit Kits.<br />

Rating plugs for the 500/600/700/800 trip units will still be<br />

available. These rating plugs are not interchangeable with<br />

the 510/610/810/910 trip units.<br />

Likewise, rating plugs for the 510/610/810/910 are not interchangeable<br />

with the 500/600/700/800 trip units.<br />

March 2001