How To Select A Retrofit Kit<br />
How To Generate A Catalog Number<br />
How To Price A Kit<br />
SWITCHGEAR (TRIP UNIT RETROFIT KITS)<br />
Customer Required Information<br />
CUSTOMER REQUIRED INFORMATION<br />
To properly select a retrofit kit, the following<br />
information is required:<br />
● Breaker Nameplate Information<br />
– Manufacturer<br />
– Breaker Type<br />
– Ampere Frame Size<br />
– Manually or Electrically Operated<br />
● Drawout or Fixed Mounting<br />
● Fused or Non-Fused<br />
● Digitrip Trip Unit Type Required<br />
– 510, 610, 810, 910<br />
● Protective Functions Required<br />
– LI, LSI, LS, LIG, LSG, LSIG<br />
Refer to pages 255-273 to view the Retrofit<br />
Kit Catalog Numbers for specific breaker<br />
manufacturers and frames. When used in<br />
To correctly price a Low Voltage Digitrip<br />
Retrofit Kit, refer to the Retrofit Kit Product<br />
Guide. It is also available on FRED II<br />
ACCESSORIES<br />
● Continuous Current Rating Required<br />
(Trip Rating of Breaker)<br />
● 3-wire or 4-wire system (determines<br />
number of sensors required)<br />
NOTE: At the time of this publication, the standard trip units for<br />
Low Voltage Digitrip Retrofit Kits are the RMS 510/610/810/<br />
910. From 1989-1996, the standard trip units were the RMS<br />
500/600/700/800. These trip units are no longer in production.<br />
Replacement orders for the 500/600/700/800 trip units<br />
will be filled by the equivalent 510/610/810/910 trip units.<br />
Remember when replacing a 500/600/700/800 unit with a<br />
510/610/810/910, the rating plug must also be replaced.<br />
conjunction with the information obtained<br />
from the section above, these pages con-<br />
(412-937-6400) as Document #9375487.<br />
This Product Guide includes base prices,<br />
Catalog Number Style Number Description<br />
PRTAAPM 1267C16G01 Aux. Power Module<br />
8779C02G02 Amptector and Digitrip Test Set (Tests for both)<br />
6503C53G01 Amptector Adapter Harness<br />
6503C54G01 Amptector 2-Piece Adapter Harness (Test Set Half)<br />
6503C55G01 Amptector 2-Piece Adapter Harness (Breaker Half)<br />
6502C83G01 External Harness (Zone Interlock Shorting Plug)<br />
8259A91G05 Auxiliary CPT Kit (Non-DS)<br />
8259A91G06 Auxiliary CPT Kit (DS)<br />
6506C34G01 Simplified Cell Harness 1 ft.<br />
6506C34G02 Simplified Cell Harness 6 ft.<br />
6506C34G03 Simplified Cell Harness 4 ft.<br />
To properly select options, the following<br />
questions need to be answered:<br />
● Will customer supply 120 VAC control<br />
power or is breaker-mounted CPT<br />
needed?<br />
– applies only to Digitrip 610, 810,<br />
and 910<br />
● Are zone interlocks required?<br />
● Does the application require relay<br />
outputs from the Digitrip 610, 810,<br />
or 910 for remote indication?<br />
● Does the breaker have an existing<br />
Amptector or Digitrip Trip Unit<br />
installed? If so, what is it?<br />
tain all the information necessary to<br />
generate a Catalog Number.<br />
adders and options for all Low Voltage<br />
Digitrip Retrofit Kits.<br />
Rating plugs for the 500/600/700/800 trip units will still be<br />
available. These rating plugs are not interchangeable with<br />
the 510/610/810/910 trip units.<br />
Likewise, rating plugs for the 510/610/810/910 are not interchangeable<br />
with the 500/600/700/800 trip units.<br />
March 2001