Junos ®<br />

<strong>OS</strong> 12.3 <strong>Ethernet</strong> <strong>Interfaces</strong> <strong>Configuration</strong> Guide<br />

• <strong>Junos®</strong> <strong>OS</strong> <strong>Ethernet</strong> <strong>Interfaces</strong><br />

Configuring a Connectivity Fault Management Action Profile<br />

You can configure an action profile and specify the action to be taken when any of the<br />

configured events occur. Alternatively, you can configure an action profile and specify<br />

default actions when connectivity to a remote maintenance association endpoint (MEP)<br />

fails.<br />

To configure the action profile name, include the action-profile statement at the [edit<br />

protocols oam ethernet connectivity-fault-management] hierarchy level.<br />

• Configuring the Action of a CFM Action Profile on page 196<br />

• Configuring the Default Actions of a CFM Action Profile on page 196<br />

• Configuring a CFM Action Profile Event on page 197<br />

Configuring the Action of a CFM Action Profile<br />

You can configure the action to be taken when any of the configured events occur.<br />

To configure the action profile’s action, include the action statement at the [edit protocols<br />

oam ethernet connectivity-fault-management action-profile profile-name] hierarchy level.<br />

[edit protocols oam]<br />

ethernet {<br />

connectivity-fault-management {<br />

action-profile bring-down {<br />

event {<br />

interface-status-tlv down;<br />

}<br />

action {<br />

interface-down;<br />

}<br />

}<br />

}<br />

}<br />

Configuring the Default Actions of a CFM Action Profile<br />

196<br />

You can configure the default actions to be taken when connectivity to a remote MEP<br />

fails.<br />

To enable the interface-down as the default action for an action profile, include the<br />

interface-down statement at the [edit protocols oam ethernet<br />

connectivity-fault-management action-profile profile-name default-actions] hierarchy<br />

level.<br />

[edit]<br />

protocols {<br />

oam {<br />

ethernet {<br />

connectivity-fault-management {<br />

Copyright © 2012, <strong>Juniper</strong> <strong>Networks</strong>, Inc.