You can specify the discovery mode used for IEEE 802.3ah OAM support. The discovery<br />

process is triggered automatically when OAM IEEE 802.3ah functionality is enabled on<br />

a port. Link monitoring is done when the interface sends periodic OAM PDUs.<br />

To configure the discovery mode, include the link-discovery statement at the [edit protocol<br />

oam ethernet link-fault-management interface interface-name] hierarchy level:<br />

[edit protocol oam ethernet link-fault-management interface interface-name]<br />

link-discovery (active | passive);<br />

In active mode, the interface discovers and monitors the peer on the link if the peer also<br />

supports IEEE 802.3ah OAM functionality. In passive mode, the peer initiates the discovery<br />

process. After the discovery process has been initiated, both sides participate in discovery.<br />

•<br />

link-discovery on page 497<br />

• IEEE 802.3ah OAM Link-Fault Management Overview on page 291<br />

• Configuring IEEE 802.3ah OAM Link-Fault Management on page 293<br />

• Enabling IEEE 802.3ah OAM Support on page 294<br />

• Configuring the OAM PDU Interval on page 295<br />

• Configuring the OAM PDU Threshold on page 296<br />

• Configuring Threshold Values for Local Fault Events on an Interface on page 297<br />

• Disabling the Sending of Link Event TLVs on page 298<br />

• Detecting Remote Faults on page 299<br />

• Configuring an OAM Action Profile on page 300<br />

• Specifying the Actions to Be Taken for Link-Fault Management Events on page 301<br />

• Monitoring the Loss of Link Adjacency on page 303<br />

• Monitoring Protocol Status on page 303<br />

• Configuring Threshold Values for Fault Events in an Action Profile on page 305<br />

• Applying an Action Profile on page 305<br />

• Setting a Remote Interface into Loopback Mode on page 306<br />

• Enabling Remote Loopback Support on the Local Interface on page 307<br />

• Example: Configuring IEEE 802.3ah OAM Support on an Interface on page 308<br />

• <strong>Junos®</strong> <strong>OS</strong> <strong>Ethernet</strong> <strong>Interfaces</strong><br />

Configuring the OAM PDU Interval<br />

Copyright © 2012, <strong>Juniper</strong> <strong>Networks</strong>, Inc.<br />

Periodic OAM PDUs are sent to perform link monitoring.<br />

Chapter 16: Configuring IEEE 802.3ah OAM Link-Fault Management<br />

You can specify the periodic OAM PDU sending interval for fault detection.<br />

To configure the sending interval, include the pdu-interval statement at the [edit protocol<br />

oam ethernet link-fault-management interface interface-name] hierarchy level:<br />