21.03.2013 Views

Junos® OS Ethernet Interfaces Configuration ... - Juniper Networks

Junos® OS Ethernet Interfaces Configuration ... - Juniper Networks

Junos® OS Ethernet Interfaces Configuration ... - Juniper Networks

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Junos ®<br />

<strong>OS</strong> 12.3 <strong>Ethernet</strong> <strong>Interfaces</strong> <strong>Configuration</strong> Guide<br />

304<br />

Related<br />

Documentation<br />

When the CCC-DOWN flag is signaled to the IEEE 802.3ah protocol, the system takes<br />

the action defined in the action statement of the action profile. For additional information<br />

about Layer 2 circuits, see the Junos <strong>OS</strong> Layer 2 Circuits Feature Guide, Junos <strong>OS</strong> VPNs<br />

<strong>Configuration</strong> Guide.<br />

To monitor the IEEE 802.3ah protocol, on the CE-facing PE router, include the<br />

protocol-down statement at the [edit protocols oam ethernet link-fault-management<br />

action-profile profile-name event] hierarchy level:<br />

•<br />

[edit protocol oam ethernet link-fault-management action-profile profile-name]<br />

protocol-down;<br />

NOTE: If multiple events are specified in the action profile, all the events<br />

must occur before the specified action is taken.<br />

protocol-down on page 539<br />

• IEEE 802.3ah OAM Link-Fault Management Overview on page 291<br />

• Configuring IEEE 802.3ah OAM Link-Fault Management on page 293<br />

• Enabling IEEE 802.3ah OAM Support on page 294<br />

• Configuring Link Discovery on page 294<br />

• Configuring the OAM PDU Interval on page 295<br />

• Configuring the OAM PDU Threshold on page 296<br />

• Configuring Threshold Values for Local Fault Events on an Interface on page 297<br />

• Disabling the Sending of Link Event TLVs on page 298<br />

• Detecting Remote Faults on page 299<br />

• Configuring an OAM Action Profile on page 300<br />

• Specifying the Actions to Be Taken for Link-Fault Management Events on page 301<br />

• Monitoring the Loss of Link Adjacency on page 303<br />

• Configuring Threshold Values for Fault Events in an Action Profile on page 305<br />

• Applying an Action Profile on page 305<br />

• Setting a Remote Interface into Loopback Mode on page 306<br />

• Enabling Remote Loopback Support on the Local Interface on page 307<br />

• Example: Configuring IEEE 802.3ah OAM Support on an Interface on page 308<br />

• <strong>Junos®</strong> <strong>OS</strong> <strong>Ethernet</strong> <strong>Interfaces</strong><br />

Copyright © 2012, <strong>Juniper</strong> <strong>Networks</strong>, Inc.