You can configure threshold values for fault events that trigger the sending of link event<br />

TLVs when the values exceed the threshold. To set threshold values for fault events on<br />

an interface, include the event-thresholds statement at the [edit protocols oam ethernet<br />

link-fault-management interface] hierarchy level.<br />

You can also configure OAM threshold values within an action profile and apply the action<br />

profile to multiple interfaces. To create an action profile, include the action-profile<br />

statement at the [edit protocols oam ethernet link-fault-management] hierarchy level.<br />

You can configure <strong>Ethernet</strong> OAM either on an aggregate interface or on each of its member<br />

links. However, we recommend that you configure <strong>Ethernet</strong> OAM on the aggregate<br />

interface, and this will internally enable <strong>Ethernet</strong> OAM on the member links.<br />

To view OAM statistics, use the show oam ethernet link-fault-management operational<br />

mode command. To clear OAM statistics, use the clear oam ethernet<br />

link-fault-management statistics operational mode command. To clear link-fault<br />

management state information and restart the link discovery process on <strong>Ethernet</strong><br />

interfaces, use the clear oam ethernet link-fault-management state operational mode<br />

command. For more information about these commands, see the Junos <strong>OS</strong> Operational<br />

Mode Commands.<br />

•<br />

event-thresholds<br />

• action-profile<br />

• IEEE 802.3ah OAM Link-Fault Management Overview on page 291<br />

• Enabling IEEE 802.3ah OAM Support on page 294<br />

• Configuring Link Discovery on page 294<br />

• Configuring the OAM PDU Interval on page 295<br />

• Configuring the OAM PDU Threshold on page 296<br />

• Configuring Threshold Values for Local Fault Events on an Interface on page 297<br />

• Disabling the Sending of Link Event TLVs on page 298<br />

• Detecting Remote Faults on page 299<br />

• Configuring an OAM Action Profile on page 300<br />

• Specifying the Actions to Be Taken for Link-Fault Management Events on page 301<br />

• Monitoring the Loss of Link Adjacency on page 303<br />

• Monitoring Protocol Status on page 303<br />

• Configuring Threshold Values for Fault Events in an Action Profile on page 305<br />

• Applying an Action Profile on page 305<br />

Chapter 16: Configuring IEEE 802.3ah OAM Link-Fault Management<br />

• Setting a Remote Interface into Loopback Mode on page 306<br />

• Enabling Remote Loopback Support on the Local Interface on page 307<br />

293

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!