pado-advertise<br />

Syntax pado-advertise;<br />

Hierarchy Level [edit protocols pppoe]<br />

Release Information Statement introduced in Junos <strong>OS</strong> Release 10.2.<br />

Description Enable named services configured in PPPoE service name tables to be advertised in<br />

Required Privilege<br />

Level<br />

Related<br />

Documentation<br />

pdu-interval<br />

PPPoE Active Discovery Offer (PADO) control packets. By default, advertisement of<br />

named services in PADO packets is disabled.<br />

NOTE: If you enable advertisement of named services in PADO packets,<br />

make sure the number and length of of all advertised service entries does<br />

not exceed the maximum transmission unit (MTU) size of the PPPoE<br />

underlying interface.<br />

interface—To view this statement in the configuration.<br />

interface-control—To add this statement to the configuration.<br />

• Configuring PPPoE Service Name Tables on page 412<br />

• Enabling Advertisement of Named Services in PADO Control Packets on page 420<br />

Syntax pdu-interval interval;<br />

Hierarchy Level [edit protocols oam ethernet link-fault-management interface interface-name]<br />

Release Information Statement introduced in Junos <strong>OS</strong> Release 8.2.<br />

Description For <strong>Ethernet</strong> interfaces on M320, M120, MX Series, and T Series routers, specify the<br />

Required Privilege<br />

periodic OAM PDU sending interval for fault detection. Used for IEEE 802.3ah Operation,<br />

Administration, and Management (OAM) support.<br />

Options interval—Periodic OAM PDU sending interval.<br />

Level<br />

Related<br />

Documentation<br />

Copyright © 2012, <strong>Juniper</strong> <strong>Networks</strong>, Inc.<br />

Range: 100 through 1000 milliseconds<br />

Default: 1000 milliseconds<br />

interface—To view this statement in the configuration.<br />

interface-control—To add this statement to the configuration.<br />

• Configuring the OAM PDU Interval on page 295<br />

Chapter 34: Summary of <strong>Ethernet</strong> <strong>Interfaces</strong> <strong>Configuration</strong> Statements<br />