• Enabling IEEE 802.3ah OAM Support on page 294<br />

• Configuring Link Discovery on page 294<br />

• Configuring the OAM PDU Interval on page 295<br />

• Configuring the OAM PDU Threshold on page 296<br />

• Configuring Threshold Values for Local Fault Events on an Interface on page 297<br />

• Disabling the Sending of Link Event TLVs on page 298<br />

• Detecting Remote Faults on page 299<br />

• Specifying the Actions to Be Taken for Link-Fault Management Events on page 301<br />

• Monitoring the Loss of Link Adjacency on page 303<br />

• Monitoring Protocol Status on page 303<br />

• Configuring Threshold Values for Fault Events in an Action Profile on page 305<br />

• Applying an Action Profile on page 305<br />

• Setting a Remote Interface into Loopback Mode on page 306<br />

• Enabling Remote Loopback Support on the Local Interface on page 307<br />

• Example: Configuring IEEE 802.3ah OAM Support on an Interface on page 308<br />

• <strong>Junos®</strong> <strong>OS</strong> <strong>Ethernet</strong> <strong>Interfaces</strong><br />

Specifying the Actions to Be Taken for Link-Fault Management Events<br />

Copyright © 2012, <strong>Juniper</strong> <strong>Networks</strong>, Inc.<br />

You can specify the action to be taken by the system when the configured link-fault event<br />

occurs. Multiple action profiles can be applied to a single interface. For each action-profile,<br />

at least one event and one action must be specified. The actions are taken only when all<br />

of the events in the action profile are true. If more than one action is specified, all the<br />

actions are executed.<br />

Chapter 16: Configuring IEEE 802.3ah OAM Link-Fault Management<br />

You might want to set a lower threshold for a specific action such as logging the error<br />

and set a higher threshold for another action such as sending a critical event TLV.<br />

To specify the action, include the action statement at the [edit protocols oam ethernet<br />

link-fault-management action-profile profile-name] hierarchy level:<br />

[edit protocol oam ethernet link-fault-management action-profile profile-name]<br />

event {<br />

link-adjacency-loss;<br />

protocol-down;<br />

}<br />

action {<br />

syslog;<br />

link-down;<br />

send-critical-event;<br />

}<br />