Conformity with UL standards and CSA standards (cUL-listed for Canada) (continued)<br />

8. Install UL certified fuses or circuit breaker between the power supply and the inverter, referring to the table below.<br />

Power supply voltage<br />

Nominal<br />

applied motor<br />

(HP)<br />

Threephase<br />

Single-<br />

phase<br />

Inverter type<br />

CT/VT mode<br />

Class J fuse size (A)<br />

Circuit breaker trip size (A)<br />

Required<br />

torque<br />

lb-in (N•m)<br />

Main terminal<br />

Aux. control power<br />

supply<br />

Aux. Fan power supply<br />

L1/R, L2/S, L3/T<br />

60C (140F)<br />

Cu wire<br />

75C (167F)<br />

Cu wire<br />

Wire size<br />

AWG (mm 2 )<br />

Main terminal<br />

Remarks<br />

60C (140F)<br />

Cu wire<br />

U, V, W<br />

75C (167F)<br />

Cu wire<br />

Remarks<br />

Aux. control power<br />

supply<br />

Aux. fan power supply<br />

230 V<br />

0.5 0.25 <strong>EQ7</strong>-20P5-C 10 5 10.6<br />

-<br />

1 0.5 <strong>EQ7</strong>-2001-C 15 10 (1.2)<br />

2 1 <strong>EQ7</strong>-2002-C 20 15<br />

CT/<br />

3 1.5 <strong>EQ7</strong>-2003-C<br />

VT<br />

30 20 15.9<br />

(1.8)<br />

5<br />

<strong>EQ7</strong>-2005-C 40 30<br />

3<br />

<strong>EQ7</strong>-2007-C<br />

7.5<br />

60 50<br />

CT<br />

<strong>EQ7</strong>-2010-C<br />

VT<br />

10 5<br />

75 75 30.9<br />

CT<br />

<strong>EQ7</strong>-2015-C<br />

(3.5)<br />

VT<br />

15 7.5<br />

100 100<br />

CT<br />

<strong>EQ7</strong>-2020-C<br />

VT<br />

20<br />

150 125<br />

CT<br />

10 <strong>EQ7</strong>-2025-C<br />

VT<br />

25<br />

175 150<br />

CT<br />

51.3<br />

<strong>EQ7</strong>-2030-C<br />

VT<br />

(5.8)<br />

30 15<br />

200 175<br />

CT<br />

10.6<br />

<strong>EQ7</strong>-2040-C<br />

(1.2)<br />

VT<br />

40 20<br />

250 200<br />

CT<br />

119.4<br />

<strong>EQ7</strong>-2050-C<br />

(13.5)<br />

VT<br />

50 25<br />

350 250<br />

CT<br />

<strong>EQ7</strong>-2060-C<br />

VT<br />

60<br />

400 300<br />

CT<br />

238.9<br />

<strong>EQ7</strong>-2075-C<br />

30<br />

VT<br />

(27)<br />

75<br />

450<br />

CT<br />

<strong>EQ7</strong>-2100-C<br />

350<br />

VT<br />

100<br />

500<br />

CT<br />

<strong>EQ7</strong>-2125-C<br />

40<br />

VT<br />

125<br />

600 400 424.7<br />

CT<br />

(48)<br />

<strong>EQ7</strong>-2150-C<br />

150 50 VT 700 500<br />

-<br />

10.6<br />

(1.2)<br />

14<br />

(2.1)<br />

10<br />

(5.3)<br />

-<br />

3<br />

(26.7)<br />

1<br />

(42.4)<br />

-<br />

14<br />

(2.1)<br />

10<br />

(5.3)<br />

8<br />

(8.4)<br />

6<br />

(13.3)<br />

4<br />

(21.2)<br />

3<br />

(26.7)<br />

2<br />

(33.6)<br />

2/0<br />

(67.4)<br />

3/0<br />

(85)<br />

4/0<br />

(107.2)<br />

2/0×2<br />

(67.4×2)<br />

3/0×2<br />

(85×2)<br />

4/0×2<br />

(107.2×2<br />

)<br />

300×2<br />

(152×2)<br />

*1<br />

-<br />

-<br />

*2<br />

*3<br />

-<br />

*2<br />

*3<br />

14<br />

(2.1)<br />

12<br />

(3.3)<br />

-<br />

4<br />

(21.2)<br />

3<br />

(26.7)<br />

2<br />

(33.6)<br />

-<br />

14<br />

(2.1)<br />

12<br />

(3.3)<br />

8<br />

(8.4)<br />

6<br />

(13.3)<br />

4<br />

(21.2)<br />

3<br />

(26.7)<br />

2<br />

(33.6)<br />

1<br />

(42.4)<br />

1/0<br />

(53.5)<br />

4/0<br />

(107.2)<br />

3/0×2<br />

(85×2)<br />

4/0×2<br />

(107.2×2<br />

)<br />

300×2<br />

(152×2)<br />

Note 1: Control circuit terminals Tightening torque: 6.1 lb-in (0.7 N•m), Recommended wire size: AWG 19 or 18 (0.65 to 0.82 mm 2 )<br />

*1 No terminal end treatment is required for connection.<br />

*2 Use 75C (167F) Cu (Copper) wire only.<br />

*3 The wire size of UL Open Type and Enclosed Type are common. Please contact us if UL Open Type exclusive wire is necessary.<br />

*1<br />

-<br />

-<br />

*2<br />

*3<br />

-<br />

*2<br />

*3<br />

-<br />

14<br />

(2.1)<br />

*1<br />

*2<br />

-<br />

14<br />

(2.1)<br />

ix

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!