• Drive control<br />

The <strong>EQ7</strong> runs under any of the following drive controls. Some function codes apply exclusively to the specific drive control, which is<br />

indicated by letters Y (Applicable) and N (Not applicable) in the "Drive control" column in the function code tables given on the following<br />

pages.<br />

Abbreviation in "Drive control"<br />

column in function code tables<br />

V/f<br />

w/o PG<br />

Control target (H18)<br />

Speed<br />

(Frequency for V/f)<br />

Drive control (F42)<br />

V/f control<br />

Dynamic torque control<br />

Vector control without speed sensor<br />

w/ PG Vector control with speed sensor<br />

Torque control Torque Vector control with/without speed sensor<br />

For details about the drive control, refer to "Function code F42 (Drive Control Selection 1)."<br />

The <strong>EQ7</strong> is a general-purpose inverter whose operation is customized by frequency-basis function codes, like<br />

conventional inverters. Under the speed-basis drive control, however, the control target is a motor speed, not a<br />

frequency, so convert the frequency to the motor speed according to the following expression.<br />

<strong>Motor</strong> speed (r/min) = 120 Frequency (Hz) Number of poles<br />