3.4.3 Checking changed function codes -- Menu #2 "Data Checking" --<br />
Menu #2 "Data Checking" in Programming mode allows you to check function codes and their data that has been<br />
changed. The function codes whose data has been changed from the factory defaults are marked with an asterisk ( ).<br />
Select a function code and press the key to view or change its data.<br />
The LCD screen transition from Menu #2 is the same as that from Menu #1 "Data Setting," except a list of function codes<br />
as shown below.<br />
Function code<br />
Changed<br />
Function code data<br />
Operation guide, scrolling horizontally to display the function of each key.<br />
Basic key operation<br />
Figure 3.11 List of Function Codes<br />
Same as the basic key operation for Menu #1 "Data Setting."<br />
3.4.4 Monitoring the running status -- Menu #3 "Drive Monitoring" --<br />
Menu #3 "Drive Monitoring" in Programming mode allows you to monitor the running status during maintenance and test<br />
running.<br />
Table 3.7 Drive Monitoring Items<br />
Page # in<br />
operation<br />
guide<br />
1<br />
2<br />
3<br />
Item Symbol Description<br />
Output frequency Fot1 Output frequency (before slip compensation)<br />
Output frequency Fot2 Output frequency (after slip compensation)<br />
Output current Iout Output current<br />
Output voltage Vout Output voltage<br />
Calculated torque TRQ Calculated output torque generated by motor<br />
Reference frequency Fref Frequency specified by a frequency command<br />
Running direction<br />
FWD<br />
REV<br />
(Blank)<br />
Forward<br />
Reverse<br />
Stopped<br />
Current limit IL Current limiting<br />
Undervoltage<br />
Voltage limit<br />
LU<br />
VL<br />
Undervoltage detected<br />
Voltage limiting<br />
Torque limit TL Torque limiting<br />
Speed limit SL Speed limiting<br />
<strong>Motor</strong> selected M1-M4 <strong>Motor</strong> 1 to 4<br />
Drive control<br />
<strong>Motor</strong> speed<br />
VF<br />
DTV<br />
VF-SC<br />
VF-PG<br />
VC-SL<br />
VC-PG<br />
SYN<br />
V/f control without slip compensation<br />
Dynamic torque vector control<br />
V/f control with slip compensation<br />
Dynamic torque vector control with speed sensor<br />
Vector control without speed sensor<br />
Vector control with speed sensor<br />
(Output frequency Hz)<br />
×<br />
120<br />
P01<br />
Load shaft speed LOD Output frequency (Hz) Function code E50<br />
Line speed LIN Output frequency (Hz) Function code E50<br />
Constant peripheral<br />
speed control monitor<br />
LSC<br />
Actual peripheral speed under constant peripheral speed<br />
control<br />
3-12