E43 LED Monitor (Item selection) E48 (LED Monitor (Speed monitor item))<br />

E43 specifies the running status item to be monitored and displayed on the LED monitor.<br />

Specifying the speed monitor with E43 provides a choice of speed-monitoring formats selectable with E48 (LED<br />

Monitor).<br />

Monitor item<br />

Display sample<br />

on the LED<br />

monitor<br />

Unit<br />

Meaning of displayed value<br />

Function<br />

code data<br />

for E43<br />

Speed monitor Function code E48 specifies what to be displayed on the LED monitor. 0<br />

Output frequency 1<br />

(before slip<br />

compensation)<br />

Output frequency 2<br />

(after slip<br />

compensation)<br />

Reference<br />

frequency<br />

Hz Frequency actually being output (E48 = 0)<br />

Hz Frequency actually being output (E48 = 1)<br />

Hz Reference frequency being specified (E48 = 2)<br />

<strong>Motor</strong> speed r/min Output frequency (Hz) x<br />

Load shaft<br />

speed<br />

120<br />

P01<br />

(E48 = 3)<br />

r/min Output frequency (Hz) E50 (E48 = 4)<br />

Line speed m/min Output frequency (Hz) E50 (E48 = 5)<br />

Display speed (%) %<br />

Output frequency<br />

Maximum frequency<br />

x 100<br />

(E48 = 7)<br />

Output current A Current output from the inverter in RMS 3<br />

Output voltage V Voltage output from the inverter in RMS 4<br />

Calculated torque %<br />

<strong>Motor</strong> output torque in %<br />

(Calculated value)<br />

Input power kW Input power to the inverter 9<br />

PID command<br />

PID feedback<br />

amount<br />

PID output %<br />

Load factor %<br />

-<br />

-<br />

PID command/feedback amount<br />

transformed to that of virtual physical value<br />

of the object to be controlled (e.g.<br />

temperature)<br />

Refer to function codes E40 and E41 for<br />

details.<br />

10<br />

12<br />

PID output in % as the maximum frequency<br />

being at 100%<br />

Load factor of the motor in % as the rated<br />

output being at 100%<br />

<strong>Motor</strong> output kW <strong>Motor</strong> output in kW 16<br />

Analog input<br />

Torque current %<br />

Magnetic flux<br />

command<br />

-<br />

%<br />

An analog input to the inverter in a format<br />

suitable for a desired scale.<br />

Refer to function codes E40 and E41 for<br />

details.<br />

Torque current command value or<br />

calculated torque current<br />

Magnetic flux command value<br />

(Available only under vector control)<br />

8<br />

14<br />

15<br />

17<br />

23<br />

24<br />

Input watt-hour<br />

kWh<br />

Input watt-hour (kWh)<br />

100<br />

25<br />

4-98