11.2 Common Specifications<br />
Item Specifications Remarks<br />
Output<br />
Functional safety<br />
Control<br />
Setting range<br />
Maximum frequency<br />
Base frequency<br />
• 25 to 500 Hz CT-Vector, V/f control *1,*2)<br />
• 25 to 200 Hz (CT-Vector, Vector control w/PG*7)<br />
• 25 to 120 Hz (CT-Vector, sensorless vector control *6, Variable Torque and Constant Torque , various controls,*1 to 7)<br />
25 to 500 Hz variable setting (Variable Torque (Model <strong>EQ7</strong>-x0P5-C or above) and Constant Torque mode : 120Hz)<br />
Starting frequency 0.1 to 60.0 Hz variable setting (sensorless vector control*6/ vector control w/PG, 0.0 Hz for *7)<br />
Carrier frequency<br />
Output frequency Accuracy<br />
(Stability)<br />
Setting resolution<br />
Speed control range<br />
Speed control accuracy<br />
Stop function Response time SIL<br />
PFH Category<br />
Performance level<br />
Control method<br />
Voltage/freq. characteristic<br />
Torque boost<br />
• 0.75 to 16 kHz variable setting (CT-Vector: <strong>EQ7</strong>-x0P5-C to <strong>EQ7</strong>-x100-C, Variable Torque:<strong>EQ7</strong>-x0P5-C to <strong>EQ7</strong>-x040-C<br />
• 0.75 to 10 kHz variable setting CT-Vector : <strong>EQ7</strong>-x125-C to <strong>EQ7</strong>-x800-C, Variable Torque: <strong>EQ7</strong>-x050-C to <strong>EQ7</strong>-x100-C<br />
• 0.75 to 6 kHz variable setting CT-Vector: <strong>EQ7</strong>-x900-C to <strong>EQ7</strong>-x1000-C Variable Torque: <strong>EQ7</strong>-x125-C to <strong>EQ7</strong>-x900-C)<br />
• 0.75 to 4 kHz variable setting Variable Torque: <strong>EQ7</strong>-x1000-C<br />
• 0.75 to 2kHz variable setting Constant Torque: <strong>EQ7</strong>-x150-C to <strong>EQ7</strong>-x800-C<br />
NOTE: Frequency drops automatically to protect the inverter depending on environmental temperature and output current.<br />
(This auto drop function can be cancelled.)<br />
• Analog setting: ±0.2% of max. frequency (at 25 ±10 °C)*1<br />
• Digital setting: ±0.01% of max. frequency (at -10 to +50 °C)<br />
• Analog setting: Analog setting: 1/3000 of max. frequency (1/1500 with V2 input)<br />
• Keypad setting: 0.01Hz (99.99Hz or less), 0.1Hz (100.0 to 500Hz)<br />
• Link setting: 1/20000 of max. frequency or 0.01 Hz (fixed)<br />
• Min. speed: Base speed 1:1500 (4P 1r/min to 1500r/min) *7<br />
• Min. speed: Base speed 1:200 (4P 7.5r/min to 1500r/min) *6<br />
• Min. speed: Base speed 1:4 *7<br />
• Min. speed: Base speed 1:2 *6<br />
• Analog setting: ±0.2% of max. frequency (at 25±10 ) *7<br />
• Digital setting: ±0.01% of max. frequency (at -10 to +50 )<br />
• Analog setting: ±0.5% or below of base speed (at 25±10 ) *6<br />
• Digital setting: ±0.5% or below of base speed (at -10 to +50 )<br />
• Safe torque off<br />
• 50ms or less<br />
• SIL 2<br />
• 1.7×10^-9<br />
(STO: acc.EN61800-5-2:2007)<br />
(delay time to "Safe torque off" from turning off either terminal [EN1] or [EN2]<br />
(Safety integrity level)<br />
(Probability of a dangerous random hardware failure per hour)<br />
• 3 (EN ISO 13849-1:2008)<br />
• d (EN ISO 13849-1:2008)<br />
• V/f control *1<br />
• Dynamic torque control *2<br />
• Vector control without speed sensor *6<br />
• Vector control with speed sensor (with an optional PG interface card mounted) *7<br />
230 V<br />
serie<br />
s<br />
460 V<br />
serie<br />
s<br />
Base frequency and max. output frequency can be set to 80 to 240V in common.<br />
The AVR control ON/OFF can be selected. *1<br />
Non-linear V/f setting (3 points) Free voltage (0 to 240V) and frequency (0 to 500Hz) can be set. *1<br />
Base frequency and max. output frequency can be set to 160 to 500V in common.<br />
The AVR control ON/OFF can be selected. *1<br />
Non-linear V/f setting (3 points) Free voltage (0 to 500V) and frequency (0 to 500Hz) can be set. *1<br />
• Auto torque boost (for constant torque load) *1 to *2<br />
• <strong>Manual</strong> torque boost: Desired torque boost (0.0 to 20.0%) can be set. *1<br />
• Select application load with function code F37. (Variable torque load or constant torque load) *1<br />
Starting torque<br />
Constant Torque mode)<br />
• <strong>EQ7</strong>-x040-C or below: 200% or higher, <strong>EQ7</strong>-x050-C or above: 180% or higher/set frequency: 0.3Hz *6<br />
• <strong>EQ7</strong>-x040-C or below: 200% or higher, <strong>EQ7</strong>-x050-C or above: 180% or higher/set frequency: 0.3Hz :Base frequency<br />
50Hz, slip compensation and auto torque boost operation *1 to*2<br />
Keypad<br />
• Multi-function keypad: Start and stop with FWD, REV, and STOP keys<br />
Start/stop operation<br />
External signals (digital inputs): Forward (Reverse) rotation, stop command (capable of 3-wire operation), coast-to-stop command,<br />
external alarm, alarm reset, etc.<br />
Link operation: Operation through RS-485 or field bus (option) communications.<br />
Switching operation command: Remote/Local switching, link switching<br />