11.2 Common Specifications<br />

Item Specifications Remarks<br />

Output<br />

Functional safety<br />

Control<br />

Setting range<br />

Maximum frequency<br />

Base frequency<br />

• 25 to 500 Hz CT-Vector, V/f control *1,*2)<br />

• 25 to 200 Hz (CT-Vector, Vector control w/PG*7)<br />

• 25 to 120 Hz (CT-Vector, sensorless vector control *6, Variable Torque and Constant Torque , various controls,*1 to 7)<br />

25 to 500 Hz variable setting (Variable Torque (Model <strong>EQ7</strong>-x0P5-C or above) and Constant Torque mode : 120Hz)<br />

Starting frequency 0.1 to 60.0 Hz variable setting (sensorless vector control*6/ vector control w/PG, 0.0 Hz for *7)<br />

Carrier frequency<br />

Output frequency Accuracy<br />

(Stability)<br />

Setting resolution<br />

Speed control range<br />

Speed control accuracy<br />

Stop function Response time SIL<br />

PFH Category<br />

Performance level<br />

Control method<br />

Voltage/freq. characteristic<br />

Torque boost<br />

• 0.75 to 16 kHz variable setting (CT-Vector: <strong>EQ7</strong>-x0P5-C to <strong>EQ7</strong>-x100-C, Variable Torque:<strong>EQ7</strong>-x0P5-C to <strong>EQ7</strong>-x040-C<br />

• 0.75 to 10 kHz variable setting CT-Vector : <strong>EQ7</strong>-x125-C to <strong>EQ7</strong>-x800-C, Variable Torque: <strong>EQ7</strong>-x050-C to <strong>EQ7</strong>-x100-C<br />

• 0.75 to 6 kHz variable setting CT-Vector: <strong>EQ7</strong>-x900-C to <strong>EQ7</strong>-x1000-C Variable Torque: <strong>EQ7</strong>-x125-C to <strong>EQ7</strong>-x900-C)<br />

• 0.75 to 4 kHz variable setting Variable Torque: <strong>EQ7</strong>-x1000-C<br />

• 0.75 to 2kHz variable setting Constant Torque: <strong>EQ7</strong>-x150-C to <strong>EQ7</strong>-x800-C<br />

NOTE: Frequency drops automatically to protect the inverter depending on environmental temperature and output current.<br />

(This auto drop function can be cancelled.)<br />

• Analog setting: ±0.2% of max. frequency (at 25 ±10 °C)*1<br />

• Digital setting: ±0.01% of max. frequency (at -10 to +50 °C)<br />

• Analog setting: Analog setting: 1/3000 of max. frequency (1/1500 with V2 input)<br />

• Keypad setting: 0.01Hz (99.99Hz or less), 0.1Hz (100.0 to 500Hz)<br />

• Link setting: 1/20000 of max. frequency or 0.01 Hz (fixed)<br />

• Min. speed: Base speed 1:1500 (4P 1r/min to 1500r/min) *7<br />

• Min. speed: Base speed 1:200 (4P 7.5r/min to 1500r/min) *6<br />

• Min. speed: Base speed 1:4 *7<br />

• Min. speed: Base speed 1:2 *6<br />

• Analog setting: ±0.2% of max. frequency (at 25±10 ) *7<br />

• Digital setting: ±0.01% of max. frequency (at -10 to +50 )<br />

• Analog setting: ±0.5% or below of base speed (at 25±10 ) *6<br />

• Digital setting: ±0.5% or below of base speed (at -10 to +50 )<br />

• Safe torque off<br />

• 50ms or less<br />

• SIL 2<br />

• 1.7×10^-9<br />

(STO: acc.EN61800-5-2:2007)<br />

(delay time to "Safe torque off" from turning off either terminal [EN1] or [EN2]<br />

(Safety integrity level)<br />

(Probability of a dangerous random hardware failure per hour)<br />

• 3 (EN ISO 13849-1:2008)<br />

• d (EN ISO 13849-1:2008)<br />

• V/f control *1<br />

• Dynamic torque control *2<br />

• Vector control without speed sensor *6<br />

• Vector control with speed sensor (with an optional PG interface card mounted) *7<br />

230 V<br />

serie<br />

s<br />

460 V<br />

serie<br />

s<br />

Base frequency and max. output frequency can be set to 80 to 240V in common.<br />

The AVR control ON/OFF can be selected. *1<br />

Non-linear V/f setting (3 points) Free voltage (0 to 240V) and frequency (0 to 500Hz) can be set. *1<br />

Base frequency and max. output frequency can be set to 160 to 500V in common.<br />

The AVR control ON/OFF can be selected. *1<br />

Non-linear V/f setting (3 points) Free voltage (0 to 500V) and frequency (0 to 500Hz) can be set. *1<br />

• Auto torque boost (for constant torque load) *1 to *2<br />

• <strong>Manual</strong> torque boost: Desired torque boost (0.0 to 20.0%) can be set. *1<br />

• Select application load with function code F37. (Variable torque load or constant torque load) *1<br />

Starting torque<br />

Constant Torque mode)<br />

• <strong>EQ7</strong>-x040-C or below: 200% or higher, <strong>EQ7</strong>-x050-C or above: 180% or higher/set frequency: 0.3Hz *6<br />

• <strong>EQ7</strong>-x040-C or below: 200% or higher, <strong>EQ7</strong>-x050-C or above: 180% or higher/set frequency: 0.3Hz :Base frequency<br />

50Hz, slip compensation and auto torque boost operation *1 to*2<br />

Keypad<br />

• Multi-function keypad: Start and stop with FWD, REV, and STOP keys<br />

Start/stop operation<br />

External signals (digital inputs): Forward (Reverse) rotation, stop command (capable of 3-wire operation), coast-to-stop command,<br />

external alarm, alarm reset, etc.<br />

Link operation: Operation through RS-485 or field bus (option) communications.<br />

Switching operation command: Remote/Local switching, link switching<br />