Code Name Data setting range<br />

Item values in parentheses indicated value for negative logic.<br />

Y: Applicable / N: Not Applicable.<br />

Change when<br />

running<br />

Data copying<br />

Default<br />

setting<br />

Drive control<br />

V/f<br />

Vector<br />

Refer to<br />

Control w/ Torque Page<br />

w/o PG control<br />

PG<br />

Y Y Y Y 4-71<br />

4-104<br />

30 (1030): Force to stop (STOP)<br />

(30 = Active OFF, 1030 = Active ON)<br />

32 (1032): Pre-excitation (EXITE) N Y Y N<br />

33 (1033): Reset PID integral and differential<br />

components (PID-RST) Y Y Y N<br />

34 (1034): Hold PID integral component (PID-HLD) Y Y Y N<br />

35 (1035): Select local (keypad) operation (LOC) Y Y Y Y<br />

39: Protect motor from dew condensation (DWP) Y Y Y Y<br />

40: Enable integrated sequence to switch<br />

to commercial power (50 Hz) (ISW50) Y N N N<br />

41: Enable integrated sequence to switch<br />

to commercial power (60 Hz) (ISW60) Y N N N<br />

47 (1047): Servo-lock command (LOCK) N N Y N<br />

49 (1049): Pulse train sign (SIGN)<br />

Y Y Y Y<br />

59 (1059): Enabled battery operation (BATRY)<br />

Y Y Y Y<br />

70 (1070): Cancel constant peripheral speed<br />

Y Y Y N<br />

control<br />

(Hz/LSC)<br />

71 (1071): Hold the constant peripheral speed<br />

Y Y Y N<br />

control frequency in the memory(LSC-HLD)<br />

72 (1072): Count the run time of commercial<br />

power-driven motor 1 (CRUN-M1) Y N N Y<br />

73 (1073): Count the run time of commercial<br />

power-driven motor 2 (CRUN-M2) Y N N Y<br />

76 (1076): Select droop control (DROOP) Y Y Y N<br />

77 (1077): Cancel PG alarm (PG-CCL) N N Y Y<br />

80 (1080): Cancel customizable logic (CLC) Y Y Y Y<br />

81 (1081): Clear all customizable logic timers (CLTC) Y Y Y Y<br />

98: Run forward (FWD) Y Y Y Y<br />

99: Run reverse (REV) Y Y Y Y<br />

100: No function assigned (NONE) Y Y Y Y<br />

Setting the value in parentheses ( ) shown above<br />

assigns a negative logic input to a terminal.<br />

4-10