• Specifying the initial value for the UP/DOWN control<br />
Specify the initial value to start the UP/DOWN control.<br />
Data for H61<br />
0<br />
1<br />
Initial value to start the UP/DOWN control<br />
Mode fixing the value at "0":<br />
The inverter automatically clears the value to "0" when restarted (including powered<br />
ON). Speed up by the UP command.<br />
Mode holding the final output frequency in the previous UP/DOWN control:<br />
The inverter internally holds the last output frequency set by the UP/DOWN control and<br />
applies the held frequency at the next restart (including powering ON).<br />
At the time of restart, if an UP or DOWN terminal command is entered before the internal frequency<br />
reaches the output frequency saved in the memory, the inverter saves the current output frequency into the<br />
memory and starts the UP/DOWN control with the new frequency.<br />
Pressing one of these keys overwrites the frequency held in the inverter.<br />
Initial frequency for the UP/DOWN control when the frequency command source is switched<br />
When the frequency command source is switched to the UP/DOWN control from other sources, the initial<br />
frequency for the UP/DOWN control is as listed below:<br />
Frequency command<br />
source<br />
Other than UP/DOWN<br />
(F01, C30)<br />
PID control<br />
Multi-frequency<br />
Communications link<br />
Switching command<br />
Select frequency<br />
command 2/1 (Hz2/Hz1)<br />
Cancel PID control<br />
(Hz/PID)<br />
Select multi-frequency<br />
(SS1, SS2, SS4 and SS8)<br />
Enable communications<br />
link<br />
via RS-485 or fieldbus (LE)<br />
Initial frequency for UP/DOWN control<br />
H61 = 0 H61 = 1<br />
Reference frequency given by the frequency<br />
command source used just before switching<br />
Reference frequency given by PID control (PID<br />
controller output)<br />
Reference frequency<br />
given by the<br />
frequency command<br />
source used just<br />
before switching<br />
Reference frequency<br />
at the time of previous<br />
UP/DOWN control<br />
4-31