Table 3.4 Items Monitored (Continued)<br />

Monitored Items on the<br />

LED Monitor<br />

PID command<br />

(Note 1)<br />

PID feedback amount<br />

PID output<br />

Analog input<br />

Torque current<br />

(Note 1)<br />

(Note 1)<br />

(Note 2)<br />

(Note 3)<br />

Magnetic flux command<br />

Input watt-hour<br />

(Note 3)<br />

Example Unit Meaning of Displayed Value<br />

Function<br />

code E43<br />

Monitor<br />

page #<br />

-<br />

PID command/feedback amount<br />

transformed to that of physical value of<br />

10 14<br />

the object to be controlled (e.g.,<br />

- temperature). Refer to function codes<br />

E40 and E41 for details.<br />

12 15<br />

%<br />

-<br />

%<br />

%<br />

kWh<br />

PID output in % as the maximum<br />

frequency being at 100%<br />

Analog input to the inverter in a format<br />

suitable for a desired scale<br />

Refer to function codes E40 and E41<br />

for details.<br />

Torque current command value or<br />

calculated torque current<br />

Magnetic flux command value<br />

(Available only under vector control)<br />

Input watt-hour (kWh)<br />

100<br />

14 16<br />

17 18<br />

23 21<br />

24 22<br />

25 23<br />

The LCD monitor (given below) shows information related to the item shown on the LED monitor. The monitor items on<br />

the LED monitor can be switched by pressing the key.<br />

Monitor items<br />

Monitor page #<br />

(See Table 3.4.)<br />

Operation guide<br />

Figure 3.5 LCD Monitor Sample Detailed for the LED Monitor Item<br />

(Note 1) These PID related items appear only under PID control specified by function code J01 (= 1, 2 or 3). When a PID<br />

command or PID output is displayed, the dot at the lowest digit on the LED monitor blinks; when a PID feedback<br />

amount is displayed, it is lit.<br />

(Note 2) The analog input monitor appears only when the analog input monitor is enabled by any of function codes E61 to E63<br />

(Select terminal function).<br />

(Note 3) Under V/f control, a zero (0) is displayed.<br />

3-6